Development of an Innovative Non-Destructive and Field-Oriented Method to Quantify the Bond Quality of Composite Strengthening Systems on Concrete Structures

被引:3
作者
Billon-Filiot, Astrid [1 ]
Taillade, Frederic [2 ]
Quiertant, Marc [3 ]
Henault, Jean-Marie [2 ]
Renaud, Jean-Claude [3 ]
Maurin, Romain [4 ]
Benzarti, Karim [5 ]
机构
[1] Elect France EDF, R&D Div, Electrotech & Mecan Struct ERMES Dept, F-91120 Palaiseau, France
[2] EDF, R&D Div, Performance Risque Ind & Surveillance Maintenance, F-78400 Chatou, France
[3] Univ Gustave Eiffel, Mat & Struct MAST Dept, Inst Francais Sci & Technol Transports Amenagemen, F-77454 Marne La Vallee, France
[4] EDF, R&D Div, Mat & Mecan Composants MMC Dept, F-77250 Ecuelles, France
[5] Univ Gustave Eiffel, Ctr Natl Rech Sci CNRS, Lab Navier, Ecole Natl Ponts & Chaussees ENPC, F-77447 Marne La Vallee, France
关键词
FRP composite strengthening systems; concrete structures; bond quality; nondestructive evaluation; pull-off test; distributed optical fiber sensing; CFRP; BEHAVIOR; TEMPERATURE; ADHESIVE; SHEAROGRAPHY; DURABILITY;
D O I
10.3390/ma13235421
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Over the last 30 years, structural reinforcement and retrofitting with externally bonded composite materials have proven to be efficient and cost-effective solutions to increase both the safety and the lifespan of civil engineering structures, including nuclear power plants. The effectiveness of the strengthening system highly depends on the level of adhesion between the fiber-reinforced polymer (FRP) composite material and the concrete surface. Therefore, on-site evaluation of the bond quality is critical to assess the performance and predict the durability of the system in place. The direct tension pull-off test is most commonly used to quantify the adhesion level, but this standardized method has many drawbacks. In the present study, it is proposed to evaluate the bond properties by using a nondestructive test (NDT) derived from the standard pull-off test. This innovative test enables the measurement of an interfacial "stiffness" which may be used as a bond quality criterion. This paper gives an insight into the performance of the proposed NDT method, when applied in laboratory conditions to concrete slabs reinforced with bonded pultruded carbon FRP plates (CFRP). Three different epoxy adhesive systems with a broad range of Young's moduli were used for the specimens' preparation, in order to vary the stiffness of the concrete/CFRP interface. The purpose was to simulate different levels of interfacial adhesion that could be observed for a single adhesive system. It was shown that the test method was able to detect differences in the interface stiffness beyond experimental uncertainties, and it should therefore enable the detection of differences in the bond quality for a given adhesive system as well. The sensitivity of the NDT was then discussed, and its detection capabilities were predicted for standard field conditions. In the last part, strain measurements were collected during the NDT, thanks to distributed optical fiber sensors (DOFS) embedded in the adhesive joints of the strengthened specimens. An analysis of the strain profiles was found to provide complementary information on the quality of the adhesive bond.
引用
收藏
页码:1 / 20
页数:20
相关论文
共 38 条
[1]  
[Anonymous], 2017, EN1766
[2]  
[Anonymous], 1999, 1542 NBN EN
[3]  
ASTM, 2015, LAM SYST BOND CONCR
[4]   Influence of temperature on the curing of an epoxy adhesive and its influence on bond behaviour of NSM-CFRP systems [J].
Benedetti, Andrea ;
Fernandes, Pedro ;
Granja, Jose L. ;
Sena-Cruz, Jose ;
Azenha, Miguel .
COMPOSITES PART B-ENGINEERING, 2016, 89 :219-229
[5]   Accelerated ageing behaviour of the adhesive bond between concrete specimens and CFRP overlays [J].
Benzarti, Karim ;
Chataigner, Sylvain ;
Quiertant, Marc ;
Marty, Celine ;
Aubagnac, Christophe .
CONSTRUCTION AND BUILDING MATERIALS, 2011, 25 (02) :523-538
[6]  
Billon A., 2016, THESIS
[7]  
Billon A., 2016, P 8 INT C FRP COMP C
[8]   Qualification of a distributed optical fiber sensor bonded to the surface of a concrete structure: a methodology to obtain quantitative strain measurements [J].
Billon, Astrid ;
Henault, Jean-Marie ;
Quiertant, Marc ;
Taillade, Frederic ;
Khadour, Aghiad ;
Martin, Renaud-Pierre ;
Benzarti, Karim .
SMART MATERIALS AND STRUCTURES, 2015, 24 (11)
[9]   Transversal joining of multi-leaf masonry through different types of connector: Experimental and theoretical investigation [J].
Cascardi, Alessio ;
Leone, Marianovella ;
Aiello, Maria Antonietta .
CONSTRUCTION AND BUILDING MATERIALS, 2020, 265
[10]   Mechanical characterization of CFRP composites by ultrasonic immersion tests: Experimental and numerical approaches [J].
Castellano, Anna ;
Foti, Pilade ;
Fraddosio, Aguinaldo ;
Marzano, Salvatore ;
Piccioni, Mario Daniele .
COMPOSITES PART B-ENGINEERING, 2014, 66 :299-310