A novel coil array for combined TMS/fMRI experiments at 3 T

被引:41
作者
de Lara, Lucia I. Navarro [1 ,2 ]
Windischberger, Christian [1 ,2 ]
Kuehne, Andre [1 ,2 ]
Woletz, Michael [1 ,2 ]
Sieg, Juergen [1 ,2 ]
Bestmann, Sven [5 ]
Weiskopf, Nikolaus [4 ]
Strasser, Bernhard [2 ,3 ]
Moser, Ewald [1 ,2 ]
Laistler, Elmar [1 ,2 ]
机构
[1] Med Univ Vienna, Ctr Med Phys & Biomed Engn, Vienna, Austria
[2] Med Univ Vienna, MR Ctr Excellence, Vienna, Austria
[3] Med Univ Vienna, Dept Biomed Imaging & Image Guided Therapy, Vienna, Austria
[4] UCL, Wellcome Trust Ctr Neuroimaging, London, England
[5] UCL, Inst Neurol, Sobell Dept Motor Neurosci & Movement Disorde, London, England
基金
英国惠康基金; 欧洲研究理事会;
关键词
TMS; fMRI; coil array; parallel imaging; concurrent TMS; TRANSCRANIAL MAGNETIC STIMULATION; CONCURRENT TMS-FMRI; PRIMARY MOTOR CORTEX; DORSAL PREMOTOR CORTEX; MAJOR DEPRESSION; FUNCTIONAL MRI; BOLD-FMRI; CAUSAL INFLUENCES; IMAGE ARTIFACTS; VISUAL-CORTEX;
D O I
10.1002/mrm.25535
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo overcome current limitations in combined transcranial magnetic stimulation (TMS) and functional magnetic resonance imaging (fMRI) studies by employing a dedicated coil array design for 3 Tesla. MethodsThe state-of-the-art setup for concurrent TMS/fMRI is to use a large birdcage head coil, with the TMS between the subject's head and the MR coil. This setup has drawbacks in sensitivity, positioning, and available imaging techniques. In this study, an ultraslim 7-channel receive-only coil array for 3 T, which can be placed between the subject's head and the TMS, is presented. Interactions between the devices are investigated and the performance of the new setup is evaluated in comparison to the state-of-the-art setup. ResultsMR sensitivity obtained at the depth of the TMS stimulation is increased by a factor of five. Parallel imaging with an acceleration factor of two is feasible with low g-factors. Possible interactions between TMS and the novel hardware were investigated and were found negligible. ConclusionThe novel coil array is safe, strongly improves signal-to-noise ratio in concurrent TMS/fMRI experiments, enables parallel imaging, and allows for flexible positioning of the TMS on the head while ensuring efficient TMS stimulation due to its ultraslim design. Magn Reson Med 74:1492-1501, 2015. (c) 2014 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine.
引用
收藏
页码:1492 / 1501
页数:10
相关论文
共 61 条
[1]   Multiband accelerated spin-echo echo planar imaging with reduced peak RF power using time-shifted RF pulses [J].
Auerbach, Edward J. ;
Xu, Junqian ;
Yacoub, Essa ;
Moeller, Steen ;
Ugurbil, Kamil .
MAGNETIC RESONANCE IN MEDICINE, 2013, 69 (05) :1261-1267
[2]  
BARKER AT, 1985, LANCET, V1, P1106
[3]   Functional MRI of cortical activations induced by transcranial magnetic stimulation (TMS) [J].
Baudewig, J ;
Siebner, HR ;
Bestmann, S ;
Tergau, F ;
Tings, T ;
Paulus, W ;
Frahm, J .
NEUROREPORT, 2001, 12 (16) :3543-3548
[4]   A randomized clinical trial of repetitive transcranial magnetic stimulation in the treatment of major depression [J].
Berman, RM ;
Narasimhan, M ;
Sanacora, G ;
Miano, AP ;
Hoffman, RE ;
Hu, XS ;
Charney, DS ;
Boutros, NN .
BIOLOGICAL PSYCHIATRY, 2000, 47 (04) :332-337
[5]   Cortical correlates of TMS-induced phantom hand movements revealed with concurrent TMS-fMRI [J].
Bestmann, S. ;
Oliviero, A. ;
Voss, M. ;
Dechent, P. ;
Lopez-Dolado, E. ;
Driver, J. ;
Baudewig, J. .
NEUROPSYCHOLOGIA, 2006, 44 (14) :2959-2971
[6]   Subthreshold high-frequency TMS of human primary motor cortex modulates interconnected frontal motor areas as detected by interleaved fMRI-TMS [J].
Bestmann, S ;
Baudewig, J ;
Siebner, HR ;
Rothwell, JC ;
Frahm, J .
NEUROIMAGE, 2003, 20 (03) :1685-1696
[7]   On the synchronization of transcranial magnetic stimulation and functional echo-planar imaging [J].
Bestmann, S ;
Baudewig, J ;
Frahm, J .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 17 (03) :309-316
[8]   Functional MRI of the immediate impact of transcranial magnetic stimulation on cortical and subcortical motor circuits [J].
Bestmann, S ;
Baudewig, J ;
Siebner, HR ;
Rothwell, JC ;
Frahm, J .
EUROPEAN JOURNAL OF NEUROSCIENCE, 2004, 19 (07) :1950-1962
[9]  
Bestmann S. R., 2008, OXFORD HDB TRANSCRAN, P569
[10]   Mapping causal interregional influences with concurrent TMS-fMRI [J].
Bestmann, Sven ;
Ruff, Christian C. ;
Blankenburg, Felix ;
Weiskopf, Nikolaus ;
Driver, Jon ;
Rothwell, John C. .
EXPERIMENTAL BRAIN RESEARCH, 2008, 191 (04) :383-402