Use of Passive Arrays for Characterization and Mapping of Cavitation Activity during HIFU Exposure

被引:45
作者
Gyoengy, M. [1 ]
Arora, M. [1 ]
Noble, J. A. [1 ]
Coussios, C. C. [1 ]
机构
[1] Univ Oxford, Dept Engn, Inst Biomed Engn, Oxford OX1 2JD, England
来源
2008 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-4 AND APPENDIX | 2008年
关键词
HIFU; cavitation; passive defection; array;
D O I
10.1109/ULTSYM.2008.0210
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Inertial cavitation occurring during HIFU exposure can act both as a promoter and as a marker of heat deposition, because bubbles re-radiate part of the incident field as broadband noise emissions that are detectable over a frequency range far removed from the main HIFU excitation frequency. In the present work, a commercially available ultrasound scanning system (with the transmit signal turned off) and linear array are used to detect the emissions emanating from cavitating bubbles passively on 64 independent channels during HIFU exposure. A novel algorithm is presented that enables localization and mapping of cavitation activity, both for the case of a single bubble and in the context of contiguous, disjoint cavitating regions. By contrast to B-mode hyperechogenicity imaging that is widely used in ultrasound-guided HIFU systems but can only operate whilst the HIFU is off, the passive imaging technique presented here can be implemented during HIFU exposure, thus providing a potential means of real-time treatment monitoring during ablation.
引用
收藏
页码:871 / 874
页数:4
相关论文
共 9 条
[1]   Role of acoustic cavitation in the delivery and monitoring of cancer treatment by high-intensity focused ultrasound (HIFU) [J].
Coussios, C. C. ;
Farny, C. H. ;
Ter Haar, G. ;
Roy, R. A. .
INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2007, 23 (02) :105-120
[2]  
Farny CH, 2006, AIP CONF PROC, V829, P348, DOI 10.1063/1.2205495
[3]   High-intensity focused ultrasound in the treatment of solid tumours [J].
Kennedy, JE .
NATURE REVIEWS CANCER, 2005, 5 (04) :321-327
[4]   Compact ultrasound scanner with built-in raw data acquisition capabilities [J].
Mo, L. Y. L. ;
DeBusschere, D. ;
Bai, W. ;
Napoilan, D. ;
Irish, A. ;
Marschall, S. ;
McLaughlin, G. W. ;
Yang, Z. ;
Carson, P. L. ;
Fowlkes, I. B. .
2007 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1-6, 2007, :2259-+
[5]   Passive imaging of underground acoustic sources [J].
Norton, SJ ;
Carr, BJ ;
Witten, AJ .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2006, 119 (05) :2840-2847
[6]   Hyperecho in ultrasound images of HIFU therapy: Involvement of cavitation [J].
Rabkin, BA ;
Zderic, V ;
Vaezy, S .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2005, 31 (07) :947-956
[7]   Treatment monitoring and thermometry for therapeutic focused ultrasound [J].
Rivens, I. ;
Shaw, A. ;
Civale, J. ;
Morris, H. .
INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2007, 23 (02) :121-139
[8]   High intensity focused ultrasound: past, present and future [J].
Ter Haar, Gail ;
Coussios, Constantin .
INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2007, 23 (02) :85-87
[9]   Real-time visualization of high-intensity focused ultrasound treatment using ultrasound imaging [J].
Vaezy, S ;
Shi, XG ;
Martin, RW ;
Chi, E ;
Nelson, PI ;
Bailey, MR ;
Crum, LA .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2001, 27 (01) :33-42