Correction of eddy-current distortions in diffusion tensor images using the known directions and strengths of diffusion gradients

被引:94
作者
Zhuang, Jiancheng
Hrabe, Jan
Kangarlu, Alayar
Xu, Dongrong
Bansal, Ravi
Branch, Craig A.
Peterson, Bradley S.
机构
[1] Columbia Univ Coll Phys & Surg, Dept Psychiat, Magnet Resonance Imaging Unit, New York, NY 10032 USA
[2] New York State Psychiat Inst & Hosp, New York, NY 10032 USA
[3] Univ So Calif, Dornsife Imaging Ctr, Los Angeles, CA USA
[4] Nathan S Kline Inst Psychiat Res, Ctr Adv Brain Imaging, Orangeburg, NY 10962 USA
关键词
diffusion tensor imaging; fractional anisotrophy; distortions; eddy currenis; echo-planar imaging;
D O I
10.1002/jmri.20727
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To correct eddy-current artifacts in diffusion ten-sor (DT) images without the need to obtain auxiliary scans for the sole, purpose of correction. Materials and Methods: DT images are susceptible to distortions caused by eddy currents induced by large diffusion gradients. We, propose a new postacquisition correction algorithm that does not require any, auxiliary reference scans. It also avoids the problematic procedure,of cross-correlating images with significantly different contrasts. A linear model is used to describe the dependence of distortion parameters (translation, scaling, and shear) on the diffusion gradients. The model is solved numerically to provide an individual correction for every diffusion-Weighted (DW) image. Results: The assumptions of the linear model were success-fully verified in a series of experiments on a silicon oil phantom. The correction obtained for this phantom was compared with correction obtained by a previously published method. The algorithm was then, shown to markedly reduce eddy-current distortions in DT images from human subjects. Conclusion: The proposed algorithm can accurately correct eddy-current artifacts in DT images. Its principal advantages are that only images with comparable signals and contrasts are cross-correlated, and no additional scans are required.
引用
收藏
页码:1188 / 1193
页数:6
相关论文
共 17 条
[1]   Elimination of eddy current artifacts in diffusion-weighted echo-planar images: The use of bipolar gradients [J].
Alexander, AL ;
Tsuruda, JS ;
Parker, DL .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (06) :1016-1021
[2]  
Anderson E., 1999, SOC IND APPL MATH
[3]   A model-based method for retrospective correction of geometric distortions in diffusion-weighted EPI [J].
Andersson, JLR ;
Skare, S .
NEUROIMAGE, 2002, 16 (01) :177-199
[4]   A simplified method to measure the diffusion tensor from seven MR images [J].
Basser, PJ ;
Pierpaoli, C .
MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (06) :928-934
[5]   ESTIMATION OF THE EFFECTIVE SELF-DIFFUSION TENSOR FROM THE NMR SPIN-ECHO [J].
BASSER, PJ ;
MATTIELLO, J ;
LEBIHAN, D .
JOURNAL OF MAGNETIC RESONANCE SERIES B, 1994, 103 (03) :247-254
[6]   Correction of eddy current-induced artefacts in diffusion tensor imaging using iterative cross-correlation [J].
Bastin, ME .
MAGNETIC RESONANCE IMAGING, 1999, 17 (07) :1011-1024
[7]   On the use of the FLAIR technique to improve the correction of eddy current induced artefacts in MR diffusion tensor imaging [J].
Bastin, ME .
MAGNETIC RESONANCE IMAGING, 2001, 19 (07) :937-950
[8]   On the use of water phantom images to calibrate and correct eddy current induced artefacts in MR diffusion tensor imaging [J].
Bastin, ME ;
Armitage, PA .
MAGNETIC RESONANCE IMAGING, 2000, 18 (06) :681-687
[9]   Eddy current correction in diffusion-weighted imaging using pairs of images acquired with opposite diffusion gradient polarity [J].
Bodammer, N ;
Kaufmann, J ;
Kanowski, M ;
Tempelmann, C .
MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (01) :188-193
[10]  
Calamante F, 1999, MAGN RESON MED, V41, P95, DOI 10.1002/(SICI)1522-2594(199901)41:1<95::AID-MRM14>3.0.CO