Urinalysis: The Automated Versus Manual Techniques; Is It Time To Change?

被引:7
作者
Ahmed, Asmaa Ismail [1 ]
Baz, Heba [1 ]
Lotfy, Sarah [1 ]
机构
[1] Cairo Univ, Fac Med, Clin & Chem Pathol Dept, Kasr Al Aini St, Cairo, Egypt
关键词
urine; automation; H800-FUS100; evaluation; URINE SEDIMENT EXAMINATION; MICROSCOPY; ANALYZERS;
D O I
10.7754/Clin.Lab.2015.150520
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Urinalysis is the third major test in clinical laboratory. Manual technique imprecision urges the need for a rapid reliable automated test. We evaluated the H800-FUS100 automatic urine sediment analyzer and compared it to the manual urinalysis technique to determine if it may be a competitive substitute in laboratories of central hospitals. Methods: 1000 urine samples were examined by the two methods in parallel. Agreement, precision, carry-over, drift, sensitivity, specificity, and practicability criteria were tested. Results: Agreement ranged from excellent to good for all urine semi-quantitative components (K > 0.4, p = 0.000), except for granular casts (K = 0.317, p = 0.000). Specific gravity results correlated well between the two methods (r = 0.884, p = 0.000). RBCS and WBCs showed moderate correlation (r = 0.42, p = 0.000) and (r = 0.44, p = 0.000), respectively. The auto-analyzer's within-run precision was >= 75% for all semi-quantitative components except for proteins (50% precision). This finding in addition to the granular casts poor agreement indicate the necessity of operator interference at the critical cutoff values. As regards quantitative contents, RBCs showed a mean of 69.8 +/- 3.95, C.V. = 5.7, WBCs showed a mean of 38.9 +/- 1.9, C.V. = 4.9). Specific gravity, pH, microalbumin, and creatinine also showed good precision results with C.Vs of 0.000, 2.6, 9.1, and 0.00 respectively. In the between run precision, positive control showed good precision (C.V. = 2.9), while negative control's C.V. was strikingly high (C.V. = 127). Carryover and drift studies were satisfactory. Manual examination of inter observer results showed major discrepancies (< 60% similar readings), while intra-observer's results correlated well with each other (r = 0.99, p = 0.000). Conclusions: Automation of urinalysis decreases observer-associated variation and offers prompt competitive results when standardized for screening away from the borderline cutoffs.
引用
收藏
页码:49 / 56
页数:8
相关论文
共 9 条
  • [1] Comparison of LabUMat-with-UriSed and iQ®200 fully automatic urine sediment analysers with manual urine analysis
    Akin, Okhan Kadir
    Serdar, Muhittin A.
    Cizmeci, Zeynep
    Genc, Ozlem
    Aydin, Suleyman
    [J]. BIOTECHNOLOGY AND APPLIED BIOCHEMISTRY, 2009, 53 : 139 - 144
  • [2] Urine sediment examination: A comparison of automated urinalysis systems and manual microscopy
    Chien, Tzu-I
    Kao, Jau-Tsuen
    Liu, Hui-Lan
    Lin, Po-Chang
    Hong, Jhih-Sian
    Hsieh, Han-Peng
    Chien, Miao-Ju
    [J]. CLINICA CHIMICA ACTA, 2007, 384 (1-2) : 28 - 34
  • [3] Preanalytical requirements of urinalysis
    Delanghe, Joris
    Speeckaert, Marijn
    [J]. BIOCHEMIA MEDICA, 2014, 24 (01) : 89 - 104
  • [4] Eltom A, 2000, SCAND J CLIN LAB INV, V60, P1, DOI 10.1080/00365510050184985
  • [5] Chronic asymptomatic pyuria precedes overt urinary tract infection and deterioration of renal function in autosomal dominant polycystic kidney disease
    Hwang, Jin Ho
    Park, Hayne Cho
    Jeong, Jong Cheol
    Baek, Seon Ha
    Han, Mi Yeun
    Bang, Kitae
    Cho, Jeong Yeon
    Yu, Suk Hee
    Yang, Jaeseok
    Oh, Kook-Hwan
    Hwang, Young-Hwan
    Ahn, Curie
    [J]. BMC NEPHROLOGY, 2013, 14
  • [6] Urine sediment examination: A comparison between the manual method and the iQ200 automated urine microscopy analyzer
    Lamchiagdhase, P
    Preechaborisutkul, K
    Lomsomboon, P
    Srisuchart, P
    Tantiniti, P
    Khan-u-ra, N
    Preechaborisutkul, B
    [J]. CLINICA CHIMICA ACTA, 2005, 358 (1-2) : 167 - 174
  • [7] Clinical laboratory automated urinalysis:: Comparison among automated microscopy, flow cytometry, two test strips analyzers, and manual microscopic examination of the urine sediments
    Mayo, S.
    Acevedo, D.
    Quinones-Torrelo, C.
    Canos, I.
    Sancho, M.
    [J]. JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2008, 22 (04) : 262 - 270
  • [8] Comparison of Fully Automated Urine Sediment Analyzers H800-FUS100 and Labumat-Urised with Manual Microscopy
    Yuksel, Hatice
    Kilic, Elif
    Ekinci, Aysun
    Evliyaoglu, Osman
    [J]. JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2013, 27 (04) : 312 - 316
  • [9] Urine sediment analysis: Analytical and diagnostic performance of sediMAX® - A new automated microscopy image-based urine sediment analyser
    Zaman, Zahur
    Fogazzi, Giovanni Battista
    Garigali, Giuseppe
    Croci, Maria Daniela
    Bayer, Gabor
    Kranicz, Tunde
    [J]. CLINICA CHIMICA ACTA, 2010, 411 (3-4) : 147 - 154