Translucent fiber post cementation using light- and dual-curing adhesive techniques and a self-adhesive material: Push-out test

被引:31
作者
Giachetti, Luca [1 ]
Grandini, Simone [2 ]
Calamai, Paolo
Fantini, Gabriele
Russo, Daniele Scaminaci
机构
[1] Univ Florence, Dept Dent, Dipartimento Odontostomatol, I-50134 Florence, Italy
[2] Univ Siena, Dept Dent, I-53100 Siena, Italy
关键词
Fiber post; Resin composite; Push-out test; Cementation; ROOT-CANAL DENTIN; INTRARADICULAR DENTIN; SYSTEMS;
D O I
10.1016/j.jdent.2009.04.007
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To compare, by means of the push-out test, the interfacial strength of two dual resin cements and one light-curing cement when used in translucent fiber post cementation. Methods: Thirty-nine, endodontically treated, single canal, extracted human bicuspids were selected. Translucent fiber posts (RelyX Fiber Post) were luted into the root canal using three resinous luting systems (n = 13). Dual-curing technique (DC): the specimens were treated with Excite DSC and RelyX ARC, which were light-cured simultaneously through the post for 60 s. Self-adhesive dual-curing technique (SADC): the specimens were treated with RelyX Unicem, which was light-cured through the post for 60 s. Light-curing technique (LC): the specimens were treated with Excite DSC and Tetric Flow, which were simultaneously light-cured through the post for 60 s. The specimens were transversally sectioned into six slices in order to perform the push-out test. Data were analyzed by two-way ANOVA followed by the Tukey-Kramer test for post-hoc comparisons at alpha = 0.05. Results: At every region, results did not show any statistical difference between the DC and LC techniques. With the LC technique bond strength values were lower at the apical region than those recorded at the coronal and middle regions. At the coronal and middle regions, bond strength values for the SADC technique were lower than those resulting when using the other two techniques. At the apical region, there was not significant difference in bond strength between the luting techniques tested. Conclusions: The interfacial strength between light-curing cement and root canal is equivalent to the interfacial strength between dual-curing cement and root canal. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:638 / 642
页数:5
相关论文
共 17 条
  • [1] Marginal adaptation in dentin of a self-adhesive universal resin cement compared with well-tried systems
    Behr, M
    Rosentritt, M
    Regnet, T
    Lang, R
    Handel, G
    [J]. DENTAL MATERIALS, 2004, 20 (02) : 191 - 197
  • [2] Microtensile bond strength between adhesive cements and root canal dentin
    Bouillaguet, S
    Troesch, S
    Wataha, JC
    Krejci, I
    Meyer, JM
    Pashley, DH
    [J]. DENTAL MATERIALS, 2003, 19 (03) : 199 - 205
  • [3] Bonding of an auto-adhesive luting material to enamel and dentin
    De Munck, J
    Vargas, M
    Van Landuyt, K
    Hikita, K
    Lambrechts, P
    Van Meerbeek, B
    [J]. DENTAL MATERIALS, 2004, 20 (10) : 963 - 971
  • [4] RELAXATION OF POLYMERIZATION CONTRACTION SHEAR-STRESS BY HYGROSCOPIC EXPANSION
    FEILZER, AJ
    DEGEE, AJ
    DAVIDSON, CL
    [J]. JOURNAL OF DENTAL RESEARCH, 1990, 69 (01) : 36 - 39
  • [5] Ferrari M, 2001, INT J PROSTHODONT, V14, P543
  • [6] Evaluation of light transmission through translucent and opaque posts
    Galhano, G. A.
    de Melo, R. M.
    Barbosa, S. H.
    Zamboni, S. C.
    Bottino, M. A.
    Scotti, R.
    [J]. OPERATIVE DENTISTRY, 2008, 33 (03) : 321 - 324
  • [7] Translucent fiber post cementation using a light-curing adhesive/composite system: SEM analysis and pull-out test
    Giachetti, L
    Russo, DS
    Bertini, F
    Giuliani, V
    [J]. JOURNAL OF DENTISTRY, 2004, 32 (08) : 629 - 634
  • [8] Goracci C, 2005, OPER DENT, V30, P627
  • [9] The contribution of friction to the dislocation resistance of bonded fiber posts
    Goracci, C
    Fabianelli, A
    Sadek, FT
    Papacchini, F
    Tay, FR
    Ferrari, M
    [J]. JOURNAL OF ENDODONTICS, 2005, 31 (08) : 608 - 612
  • [10] Light-transmitting Ability of Marketed Fiber Posts
    Goracci, C.
    Corciolani, G.
    Vichi, A.
    Ferrari, M.
    [J]. JOURNAL OF DENTAL RESEARCH, 2008, 87 (12) : 1122 - 1126