Amperometric Detection of Tryptophane and Pyridoxine on a Dual <bold>Screen-Printed</bold> Electrode Modified by Gold Nanoparticles in a Flow-Injection System

被引:6
|
作者
Shaidarova, L. G. [1 ]
Chelnokova, I. A. [1 ]
Il'ina, M. A. [1 ]
Leksina, Yu. A. [1 ]
Budnikov, H. C. [1 ]
机构
[1] Kazan Fed Univ, Butlerov Inst Chem, Kazan 420008, Russia
关键词
chemically modified electrodes; gold nanoparticles; electrooxidation of tryptophane and pyridoxine; flow-injection analysis; dual screen-printed electrode; LIQUID-CHROMATOGRAPHY METHOD; CHEMILUMINESCENCE DETERMINATION; ASCORBIC-ACID; RUTHENIUM; THIAMINE; BEHAVIOR; IRIDIUM;
D O I
10.1134/S106193481906011X
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method is developed for the flow-injection amperometric determination of tryptophane and pyridoxine on a screen-printed electrode with electrodeposited gold nanoparticles. The dependence of the analytical signal on the concentrations of tryptophane and pyridoxine on the logarithmic coordinates is linear in the ranges from 5 x 10(-7) to 5 x 10(-3) and from 5 x 10(-8)x to 5 x 10(-3) M, respectively. A possibility of the simultaneous amperometric determination of tryptophane and pyridoxine on a dual screen-printed electrode modified by gold nanoparticles in a flow-injection system is shown. The developed method is approved in the determination of tryptophane and pyridoxine in medicinal preparations.
引用
收藏
页码:584 / 590
页数:7
相关论文
共 50 条
  • [1] Amperometric Detection of Tryptophane and Pyridoxine on a Dual Screen-Printed Electrode Modified by Gold Nanoparticles in a Flow-Injection System
    L. G. Shaidarova
    I. A. Chelnokova
    M. A. Il’ina
    Yu. A. Leksina
    H. C. Budnikov
    Journal of Analytical Chemistry, 2019, 74 : 584 - 590
  • [2] Amperometric Detection of Creatinine and Uric Acid at the Screen-Printed Electrode Modified By Gold Nanoparticles in Flow-Injection Analysis
    Shaidarova, Larisa G.
    Chelnokova, Irina A.
    II'ina, Marina A.
    Leksina, Yulia A.
    Gedmina, Anna V.
    Budnikov, Herman K.
    RESEARCH JOURNAL OF PHARMACEUTICAL BIOLOGICAL AND CHEMICAL SCIENCES, 2015, 6 (05): : 1629 - 1635
  • [3] Dual Screen-Printed Electrode Modified by Gold - Palladium Binary System for Flow-Injection Amperometric Determination of Dopamine and Ascorbic Acid
    Shaidarova, L. G.
    Leksina, Y. A.
    Chelnokova, I. A.
    Il'ina, M. A.
    Gedmina, A. V.
    Budnikov, H. C.
    UCHENYE ZAPISKI KAZANSKOGO UNIVERSITETA-SERIYA ESTESTVENNYE NAUKI, 2018, 160 (01): : 40 - 53
  • [4] A Dual Screen-Printed Electrode with Palladium Nanoparticles for the Flow-Injection Amperometric Determination of Dopamine and Adrenaline
    L. G. Shaidarova
    I. A. Chelnokova
    Yu. A. Leksina
    A. V. Gedmina
    H. C. Budnikov
    Journal of Analytical Chemistry, 2020, 75 : 1059 - 1065
  • [5] Gold Nanoparticles Decorated on Carbon Nanotube Modified Screen-printed Electrode for Flow Injection Amperometric Determination of Methyldopa
    Upan, Jantima
    Themsirimongkon, Suwaphid
    Saipanya, Surin
    Jakmunee, Jaroon
    CHIANG MAI JOURNAL OF SCIENCE, 2019, 46 (03): : 537 - 546
  • [6] Flow injection amperometric determination of isoniazid using a screen-printed carbon electrode modified with silver hexacyanoferrates nanoparticles
    de Oliveira, Paulo Roberto
    Oliveira, Marcela Mohallem
    Zarbin, Aldo J. G.
    Marcolino-Junior, Luiz Humberto
    Bergamini, Marcio F.
    SENSORS AND ACTUATORS B-CHEMICAL, 2012, 171 : 795 - 802
  • [7] Moxifloxacin Hydrochloride Electrochemical Detection at Gold Nanoparticles Modified Screen-Printed Electrode
    Shehata, M.
    Fekry, Amany M.
    Walcarius, Alain
    SENSORS, 2020, 20 (10)
  • [8] A highly sensitive flow injection amperometric glucose biosensor using a gold nanoparticles/polytyramine/Prussian blue modified screen-printed carbon electrode
    Khumngern, Suntisak
    Jirakunakorn, Ratchaneekorn
    Thavarungkul, Panote
    Kanatharana, Proespichaya
    Numnuam, Apon
    BIOELECTROCHEMISTRY, 2021, 138
  • [9] A highly sensitive flow injection amperometric glucose biosensor using a gold nanoparticles/polytyramine/Prussian blue modified screen-printed carbon electrode
    Khumngern, Suntisak
    Jirakunakorn, Ratchaneekorn
    Thavarungkul, Panote
    Kanatharana, Proespichaya
    Numnuam, Apon
    Bioelectrochemistry, 2021, 138
  • [10] Sequential Injection Amperometric Determination of Glucose in Saliva Using a Screen-Printed Electrode Modified with a Gold–Cobalt Binary System
    L. G. Shaidarova
    I. A. Chelnokova
    I. A. Gafiatova
    A. V. Gedmina
    H. C. Budnikov
    Journal of Analytical Chemistry, 2023, 78 : 372 - 377