Development of a thermal sensor to probe cell viability and concentration in cell suspensions

被引:14
作者
Park, Byoung Kyoo [1 ]
Yi, Namwoo [2 ]
Park, Jaesung [3 ]
Kim, Yonggoo [4 ]
Kim, Dongsik [2 ]
机构
[1] Yonam Inst Digital Technol, Dept Mech Engn, Jinju 660750, South Korea
[2] POSTECH, Dept Mech Engn, Pohang 790784, South Korea
[3] POSTECH, Sch Interdisciplinary Biosci & Bioengn, Pohang 790784, South Korea
[4] Catholic Univ Korea, Sch Med, Seoul, South Korea
关键词
CONDUCTIVITY MEASUREMENT; 3-OMEGA METHOD; CULTURE; HEAT; IMPEDANCE; SURFACE; LIQUID; DEATH;
D O I
10.1063/1.4871758
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
This paper presents a novel biothermal sensor to probe cell viability and concentration of a cell suspension. The sensing technique exploits the thermophysical properties of the suspension, so no labeling of suspended cells is required. When the sensor is periodically heated, the amplitude and phase of the thermal signal are dependent on the thermal properties of the cell suspension, particularly the thermal conductivity k. We measured k of HeLa, hepatocyte, and NIH-3T3 J2 cell suspensions with various concentrations and viabilities. The results demonstrate that the k of a cell suspension has a strong correlation with its concentration and viability. Accordingly, k can be employed as an index of cell concentration and viability. Furthermore, without data processing to obtain k, the electric signal that reflects the thermal response of the sensor can be used as a tool to probe viability of a cell suspension in real time. The proposed thermal sensing technique offers label-free, non-invasive, long-term, and real-time means to probe the viability and concentration of cells in a suspension. (C) 2014 Author(s). All article content, except where otherwise noted, is licensed under a Creative Commons Attribution 3.0 Unported License.
引用
收藏
页数:8
相关论文
共 31 条
[1]  
[Anonymous], CURR PROTOC IMMUNOL, DOI DOI 10.1002/0471142735IMA03BS21
[2]   THERMAL-CONDUCTIVITY MEASUREMENT FROM 30-K TO 750-K - THE 3-OMEGA METHOD [J].
CAHILL, DG .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1990, 61 (02) :802-808
[3]   On-line measurements and control of viable cell density in cell culture manufacturing processes using radio-frequency impedance [J].
Carvell, John P. ;
Dowd, Jason E. .
CYTOTECHNOLOGY, 2006, 50 (1-3) :35-48
[4]   Thermal conductivity measurement under hydrostatic pressure using the 3ω method [J].
Chen, F ;
Shulman, J ;
Xue, Y ;
Chu, CW ;
Nolas, GS .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2004, 75 (11) :4578-4584
[5]   Real-time thermal characterization of 12 nl fluid samples in a microchannel [J].
Choi, Sun Rock ;
Kim, Dongsik .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2008, 79 (06)
[6]   A micromachined AC thermal sensor for monitoring the liquid-gas interface in a microchannel [J].
Choi, Sun Rock ;
Hong, Jonggan ;
Kim, Dongsik .
SENSORS AND ACTUATORS A-PHYSICAL, 2009, 150 (01) :40-45
[7]   3ω method to measure thermal properties of electrically conducting small-volume liquid [J].
Choi, Sun Rock ;
Kim, Joonwon ;
Kim, Dongsik .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2007, 78 (08)
[8]  
Dittmar R, 2012, TISSUE ENG PART C-ME, V18, P198, DOI [10.1089/ten.tec.2011.0334, 10.1089/ten.TEC.2011.0334]
[9]   HEPATOCYTE FUNCTION AND EXTRACELLULAR-MATRIX GEOMETRY - LONG-TERM CULTURE IN A SANDWICH CONFIGURATION [J].
DUNN, JCY ;
YARMUSH, ML ;
KOEBE, HG ;
TOMPKINS, RG .
FASEB JOURNAL, 1989, 3 (02) :174-177
[10]   A new electro-optical approach to rapid assay of cell viability [J].
Guliy, Olga I. ;
Bunin, Victor D. ;
O'Neil, Daniel ;
Ivnitski, Dmitri ;
Ignatov, Oleg V. .
BIOSENSORS & BIOELECTRONICS, 2007, 23 (04) :583-587