Multidetector computed tomography myocardial perfusion imaging during adenosine stress

被引:223
作者
George, Richard T.
Silva, Caterina
Cordeiro, Marco A. S.
DiPaula, Anthony
Thompson, Douglas R.
McCarthy, William F.
Ichihara, Takashi
Lima, Joao A. C.
Lardo, Albert C.
机构
[1] Johns Hopkins Sch Med, Div Cardiol, Dept Med, Baltimore, MD 21205 USA
[2] Johns Hopkins Sch Med, Dept Biomed Engn, Baltimore, MD 21205 USA
[3] Johns Hopkins Sch Med, Dept Surg, Baltimore, MD 21205 USA
[4] Johns Hopkins Sch Med, Dept Radiol, Baltimore, MD 21205 USA
[5] Maryland Med Res Inst, Baltimore, MD USA
[6] Toshiba Med Syst Corp, Otawara, Japan
关键词
D O I
10.1016/j.jacc.2006.04.014
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES The purpose of this study is to validate the accuracy of multidetector computed tomography (MDCT) to measure differences in regional myocardial perfusion during adenosine stress in a canine model of left anterior descending (LAD) artery stenosis, during first-pass, contrast-enhanced helical MDCT. BACKGROUND Myocardial perfusion imaging by MDCT may have significant implications in the diagnosis and treatment of coronary artery disease. METHODS Eight dogs were prepared with a LAD stenosis, and contrast-enhanced MDCT imaging was performed 5 min into adenosine infusion (0.14 to 0.21 mg/kg/min). Images were analyzed using a semiautomated approach to define the regional signal density (SD) ratio (myocardial SD/left ventricular blood pool SD) in stenosed and remote territories, and then compared with microsphere myocardial blood flow (MBF) measurements. RESULTS Mean MBF in stenosed versus remote territories was 1.37 +/- 0.46 ml/g/min and 1.29 +/- 0.48 ml/g/min at baseline (p = NS) and 2.54 +/- 0.93 ml/g/min and 8.94 +/- 5.74 ml/g/min during adenosine infusion, respectively (p < 0.05). Myocardial SD was 92.3 +/- 39.5 HU in stenosed versus 180.4 +/- 41.9 HU in remote territories (p < 0.001). There was a significant linear association of the SD ratio with MBF in the stenosed territory (R = 0.98, p = 0.001) and between regional myocardial SD ratio and MBF < 8 ml/g/min, slope = 0.035, SE = 0.007, p < 0.0001. Overall, there was a significant non-linear relationship over the range of flows studied (LR chi-square [2 degrees of freedom] = 31.8, p < 0.0001). CONCLUSIONS Adenosine-augmented MDCT myocardial perfusion imaging provides semiquantitative measurements of myocardial perfusion during first-pass MDCT imaging in a canine model of LAD stenosis.
引用
收藏
页码:153 / 160
页数:8
相关论文
共 34 条
  • [1] Validation of minimally invasive measurement of myocardial perfusion using electron beam computed tomography and application in human volunteers
    Bell, MR
    Lerman, LO
    Rumberger, JA
    [J]. HEART, 1999, 81 (06) : 628 - 635
  • [2] Mechanism of inducible regional dysfunction during dipyridamole stress
    Bin, JP
    Le, E
    Pelberg, RA
    Coggins, MP
    Wei, K
    Kaul, S
    [J]. CIRCULATION, 2002, 106 (01) : 112 - 117
  • [3] Bottcher M, 1997, J NUCL MED, V38, P442
  • [4] Modelling of cardiac imaging data with spatial correlation
    Bowman, FD
    Waller, LA
    [J]. STATISTICS IN MEDICINE, 2004, 23 (06) : 965 - 985
  • [5] Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart - A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association
    Cerqueira, MD
    Weissman, NJ
    Dilsizian, V
    Jacobs, AK
    Kaul, S
    Laskey, WK
    Pennell, DJ
    Rumberger, JA
    Ryan, T
    Verani, MS
    [J]. CIRCULATION, 2002, 105 (04) : 539 - 542
  • [6] TL-201 SCINTIGRAPHY AFTER INTRAVENOUS-INFUSION OF ADENOSINE COMPARED WITH EXERCISE THALLIUM TESTING IN THE DIAGNOSIS OF CORONARY-ARTERY DISEASE
    COYNE, EP
    BELVEDERE, DA
    VANDESTREEK, PR
    WEILAND, FL
    EVANS, RB
    SPACCAVENTO, LJ
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 17 (06) : 1289 - 1294
  • [7] COMPARISON OF ADENOSINE AND EXERCISE TL-201 SINGLE-PHOTON EMISSION COMPUTED-TOMOGRAPHY (SPECT) MYOCARDIAL PERFUSION IMAGING
    GUPTA, NC
    ESTERBROOKS, DJ
    HILLEMAN, DE
    MOHIUDDIN, SM
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 19 (02) : 248 - 257
  • [8] HETEROGENEOUS MICROVASCULAR CORONARY VASODILATION BY ADENOSINE AND NITROGLYCERIN IN DOGS
    HABAZETTL, H
    VOLLMAR, B
    CHRIST, M
    BAIER, H
    CONZEN, PF
    PETER, K
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1994, 76 (05) : 1951 - 1960
  • [9] Hacker M, 2005, J NUCL MED, V46, P1294
  • [10] Acute myocardial infarction: Contrast-enhanced multi-detector row CT in a porcine model
    Hoffman, U
    Millea, R
    Enzweiler, C
    Ferencik, M
    Gulick, S
    Titus, J
    Achenbach, S
    Kwait, D
    Sosnovik, D
    Brady, TJ
    [J]. RADIOLOGY, 2004, 231 (03) : 697 - 701