A simple scatter correction method for dual energy contrast-enhanced digital breast tomosynthesis

被引:2
作者
Lu, Yihuan [1 ]
Lau, Beverly [2 ]
Hu, Yue-Houng [2 ]
Zhao, Wei [2 ]
Gindi, Gene [1 ,2 ]
机构
[1] SUNY Stony Brook, Dept Elect Engn, Stony Brook, NY 11790 USA
[2] SUNY Stony Brook, Dept Radiol, Stony Brook, NY 11794 USA
来源
MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING | 2014年 / 9033卷
关键词
digital breast tomosynthesis; scatter correction; dual energy; contrast enhanced; mammography; MAMMOGRAPHY;
D O I
10.1117/12.2043190
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Dual-Energy Contrast Enhanced Digital Breast Tomosynthesis (DE-CE-DBT) has the potential to deliver diagnostic information for vascularized breast pathology beyond that available from screening DBT. DE-CE-DBT involves a contrast (iodine) injection followed by a low energy (LE) and a high energy (HE) acquisitions. These undergo weighted subtraction then a reconstruction that ideally shows only the iodinated signal Scatter in the projection data leads to "cupping" artifacts that can reduce the visibility and quantitative accuracy of the iodinated signal The use of filtered backprojection (FBP) reconstruction ameliorates these types of artifacts, but the use of FBP precludes the advantages of iterative reconstructions. This motivates an effective and clinically practical scatter correction (SC) method for the projection data. We propose a simple SC method, applied at each acquisition angle. It uses scatter-only data at the edge of the image to interpolate a scatter estimate within the breast region. The interpolation has an approximately correct spatial profile but is quantitatively inaccurate. We further correct the interpolated scatter data with the aid of easily obtainable knowledge of SPR (scatter-to-primary ratio) at a single reference point. We validated the SC method using a CIRS breast phantom with iodine inserts. We evaluated its efficacy in terms of SDNR and iodine quantitative accuracy. We also applied our SC method to a patient DE-CE-DBT study and showed that the SC allowed detection of a previously confirmed tumor at the edge of the breast. The SC method is quick to use and may be useful in a clinical setting.
引用
收藏
页数:12
相关论文
共 50 条
  • [11] System Calibration for Quantitative Contrast-Enhanced Digital Breast Tomosynthesis (CEDBT)
    Hill, Melissa L.
    Mainprize, James G.
    Yaffe, Martin J.
    BREAST IMAGING, IWDM 2016, 2016, 9699 : 645 - 653
  • [12] Demonstration of a Scatter Correction Technique in Digital Breast Tomosynthesis
    Inscoe, Christy R.
    Tucker, Andrew W.
    Zhou, Otto Z.
    Lu, Jianping
    MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668
  • [13] Radiomic features analysis by digital breast tomosynthesis and contrast-enhanced dual-energy mammography to detect malignant breast lesions
    Fusco, Roberta
    Vallone, Paolo
    Filice, Salvatore
    Granata, Vincenza
    Petrosino, Teresa
    Rubulotta, Maria Rosaria
    Setola, Sergio Venanzio
    Maio, Francesca
    Raiano, Concetta
    Raiano, Nicola
    Siani, Claudio
    Di Bonito, Maurizio
    Sansone, Mario
    Botti, Gerardo
    Petrillo, Antonella
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2019, 53
  • [14] Application of the Ordered-Subsets Transmission Reconstruction Algorithm to Contrast-Enhanced Dual-Energy Digital Breast Tomosynthesis
    Lu, Yihuan
    Peng, Boyu
    Scaduto, David A.
    Zhao, Wei
    Gindi, Gene
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [15] Contrast enhanced imaging with a stationary digital breast tomosynthesis system
    Puett, Connor
    Calliste, Jabari
    Wu, Gongting
    Inscoe, Christina R.
    Lee, Yueh Z.
    Zhou, Otto
    Lu, Jianping
    MEDICAL IMAGING 2017: PHYSICS OF MEDICAL IMAGING, 2017, 10132
  • [16] Dual-energy contrast enhanced digital breast tomosynthesis: concept, method and evaluation on phantoms
    Puong, Sylvie
    Patoureaux, Fanny
    Iordache, Razvan
    Bouchevreau, Xavier
    Muller, Serge
    MEDICAL IMAGING 2007: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2007, 6510
  • [17] Optimization of beam parameters and iodine quantification in dual-energy contrast enhanced digital breast tomosynthesis
    Puong, Sylvie
    Bouchevreau, Xavier
    Duchateau, Nicolas
    Iordache, Razvan
    Muller, Serge
    MEDICAL IMAGING 2008: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2008, 6913
  • [18] Effects of angular range on lesion margin assessment in Contrast-Enhanced Digital Breast Tomosynthesis
    Huang, Hailiang
    Scaduto, David A.
    Rinaldi, Kim
    Liu, Jingxuan
    Wicklein, Julia
    Hoernig, Mathias
    Mertelmeier, Thomas
    Fisher, Paul R.
    Zhao, Wei
    MEDICAL IMAGING 2019: PHYSICS OF MEDICAL IMAGING, 2019, 10948
  • [19] A new breast phantom suitable for digital mammography, contrast-enhanced digital mammography and digital breast tomosynthesis
    Zhang, Changsheng
    Fu, Jian
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (04)
  • [20] 2D and 3D registration methods for dual-energy contrast-enhanced digital breast tomosynthesis
    Lau, Kristen C.
    Roth, Susan
    Maidment, Andrew D. A.
    MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033