Measuring Near-Surface Soil Thermal Properties with the Heat-Pulse Method: Correction of Ambient Temperature and Soil-Air Interface Effects

被引:33
|
作者
Zhang, Xiao [1 ]
Heitman, Joshua [2 ]
Horton, Robert [3 ]
Ren, Tusheng [1 ]
机构
[1] China Agr Univ, Dept Soil & Water Sci, Beijing 100193, Peoples R China
[2] N Carolina State Univ, Soil Sci Dept, Raleigh, NC 27695 USA
[3] Iowa State Univ, Dept Agron, Ames, IA 50011 USA
基金
美国国家科学基金会;
关键词
WATER-CONTENT; PROBE; CONDUCTIVITY; EVAPORATION;
D O I
10.2136/sssaj2014.01.0014
中图分类号
S15 [土壤学];
学科分类号
0903 ; 090301 ;
摘要
Large temperature gradients and proximity to the soil-air interface affect the measurement accuracy of thermal properties with the heat-pulse probe (HPP). The objective of this study is to improve the HPP methodology for measuring soil heat capacity (C) and thermal conductivity (l) in the surface soil layer by reducing the effects of ambient temperature variation and the soil-air interface. Thermal properties of eight soil layers (0-6, 2-6, 6-12, 12-18, 18-24, 24-30, 30-36, and 36-42 mm) were measured with the HPP in a loamy sand soil in two experiments with varying moisture conditions. Results were compared with values estimated with the de Vries models. Temperature drift caused by natural warming and cooling was removed from the observed trend of ambient temperature change with time. The influence of the soil-air interface was taken into account with a new solution using pulsed infinite line source theory with adiabatic boundary conditions. When ambient temperature change was considered, the HPP were capable of providing reasonable thermal property results at soil depths greater than 6 mm. For the 0- to 6-mm depth layer, the HPP signals were affected simultaneously by ambient temperature drift and the soil-air interface, and mixed scenarios were produced. Around midday, the HPP temperature by time curves were distorted so seriously that the effect of ambient temperature drift could not be removed. At other times, large errors were observed in the estimated C and l data, even when ambient temperature drift was removed. When the effect of the soil-air interface was accounted for, however, C and l measurement accuracies in the 0- to 6-mm layer were improved significantly. The RMSE of C was reduced from 0.43 MJ m(-3) degrees C-1 to 0.29 MJ m(-3) degrees C-1 in Exp. 1, and from 0.52 MJ m(-3) degrees C-1 to 0.34 MJ m(-3) degrees C-1 in Exp. 2. Significant error reduction was also observed in l measurements. Thus, to obtain accurate field measurements of shallow soil thermal properties, the ambient temperature drift and the impact of the soil-air interface must be properly taken into account.
引用
收藏
页码:1575 / 1583
页数:9
相关论文
共 23 条
  • [1] Thermal Property Measurement Errors with Heat-Pulse Sensors Positioned near a Soil-Air Interface
    Xiao, X.
    Zhang, X.
    Ren, T.
    Horton, R.
    Heitman, J. L.
    SOIL SCIENCE SOCIETY OF AMERICA JOURNAL, 2015, 79 (03) : 766 - 771
  • [2] Advances in heat-pulse methods: Measuring near-surface soil water content
    Zhang, Xiao
    Ren, Tusheng
    Heitman, Joshua
    Horton, Robert
    SOIL SCIENCE SOCIETY OF AMERICA JOURNAL, 2020, 84 (05) : 1376 - 1383
  • [3] Advances in the heat-pulse technique: Improvements in measuring soil thermal properties
    Liu, Gang
    Lu, Yili
    Wen, Minmin
    Ren, Tusheng
    Horton, Robert
    SOIL SCIENCE SOCIETY OF AMERICA JOURNAL, 2020, 84 (05) : 1361 - 1370
  • [4] Effects of moss biocrusts on near-surface soil moisture are underestimated in drylands: Insights from a heat-pulse soil moisture sensor
    Li, Shenglong
    Bowker, Matthew A.
    Chamizo, Sonia
    Xiao, Bo
    GEODERMA, 2022, 413
  • [5] Overlooked biocrust impacts on surface soil thermal properties: Evidence from heat-pulse sensing on large volume samples
    Chen, Junru
    Xiao, Bo
    Heitman, Joshua
    EUROPEAN JOURNAL OF SOIL SCIENCE, 2024, 75 (06)
  • [6] Optimized measurement of frozen soil thermal properties using a heat-pulse sensor
    Zhao, Tianyue
    Zhang, Yuanyuan
    He, Hailong
    Horton, Robert
    Liu, Gang
    GEODERMA, 2024, 442
  • [7] Wind effects on soil thermal properties measured by the dual-probe heat pulse method
    Sang, Yujie
    Liu, Gang
    Horton, Robert
    SOIL SCIENCE SOCIETY OF AMERICA JOURNAL, 2020, 84 (02) : 414 - 424
  • [8] Open hardware portable dual-probe heat-pulse sensor for measuring soil thermal properties and water content
    Ravazzani, Giovanni
    COMPUTERS AND ELECTRONICS IN AGRICULTURE, 2017, 133 : 9 - 14
  • [9] Theory and Solutions of Heat Pulse Method for Determining Soil Thermal Properties
    Wang, Jiaming
    He, Dong
    Dyck, Miles
    He, Hailong
    2019 5TH INTERNATIONAL CONFERENCE ON ENVIRONMENTAL SCIENCE AND MATERIAL APPLICATION, 2020, 440
  • [10] Using Late Time Data Improves the Heat-Pulse Method for Estimating Soil Thermal Properties with the Pulsed Infinite Line Source Theory
    Lu, Yili
    Wang, Yajing
    Ren, Tusheng
    VADOSE ZONE JOURNAL, 2013, 12 (04)