Assessing the seismic vulnerability of a historical building

被引:83
|
作者
Barbieri, Gaia [1 ]
Biolzi, Luigi [1 ]
Bocciarelli, Massimiliano [1 ]
Fregonese, Luigi [1 ]
Frigeri, Aronne [1 ]
机构
[1] Politecn Milan, Dept Architecture Built Environm & Construct Engn, I-20133 Milan, Italy
关键词
Masonry; Seismic vulnerability; Finite element modeling; Restoration; MASONRY BUILDINGS; LIMIT ANALYSIS; DAMAGE MODEL; WALLS;
D O I
10.1016/j.engstruct.2013.09.045
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The work deals with the structural analysis of an historic masonry building, Palazzo del Capitano in Mantua, subject to significant static instabilities due to an overturning of the longitudinal facades, probably related to ground settlements. The exact geometry of the structure is acquired by means of the laser scanning technique and thanks to previous investigations, the main mechanical properties of the materials are reasonably well defined. Based on these information a three-dimensional finite element model of the entire structure is implemented, taking into consideration all the geometrical (contact between not connected panels and large displacement effects) and material (elasto plastic damage behavior of the masonry) nonlinearities, in order to investigate the seismic behavior of the structure by means of nonlinear dynamic analysis. The outcome of the analysis points out that the longitudinal facade, overlooking Piazza Sordello, is poorly constrained both to the floors and to the transverse bracing elements, therefore not able to counteract its deformation when a seismic event occurs. Finally suggestions to reduce the seismic vulnerability of the building are critically assessed by the implemented finite element model. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:523 / 535
页数:13
相关论文
共 50 条
  • [1] Assessment of Seismic Vulnerability of a Historical Masonry Building
    Ceroni, Francesca
    Pecce, Marisa
    Sica, Stefania
    Garofano, Angelo
    BUILDINGS, 2012, 2 (03): : 332 - 358
  • [2] Seismic vulnerability assessment of a historical building in Tunisia
    Ei-Borgi, S.
    Choura, S.
    Neifar, M.
    Smaoui, H.
    Majdoub, M. S.
    Cherif, D.
    SMART STRUCTURES AND SYSTEMS, 2008, 4 (02) : 209 - 220
  • [3] The impact of the cultural value on the seismic vulnerability of a historical building
    Onescu, I.
    Onescu, E.
    Mosoarca, M.
    4TH WORLD MULTIDISCIPLINARY CIVIL ENGINEERING-ARCHITECTURE-URBAN PLANNING SYMPOSIUM - WMCAUS, 2019, 603
  • [4] Seismic vulnerability assessment of a historical masonry building: Pandone Castle
    Tilocca, Anna Rosa
    Ferracuti, Barbara
    Mazzotti, Claudio
    Bovo, Marco
    2015 IEEE WORKSHOP ON ENVIRONMENTAL, ENERGY AND STRUCTURAL MONITORING SYSTEMS (EESMS), 2015, : 174 - 179
  • [5] Thermography Investigation and Seismic Vulnerability Assessment of a Historical Vaulted Masonry Building
    Cascardi, Alessio
    Longo, Fabio
    Perrone, Daniele
    Lassandro, Paola
    Aiello, Maria Antonietta
    HERITAGE, 2022, 5 (03): : 2041 - 2061
  • [6] Cyclic Behaviour, Dynamic Analysis and Seismic Vulnerability of Historical Building Archetypes in Hungary
    Morais, E. Charters
    Vigh, L. G.
    Krahling, J.
    INTERNATIONAL JOURNAL OF ARCHITECTURAL HERITAGE, 2021, 15 (07) : 1022 - 1042
  • [7] SEISMIC VULNERABILITY ASSESSMENT OF A ROMANIAN HISTORICAL BUILDING UNDER NEAR-SOURCE EARTHQUAKE
    Chieffo, N.
    Formisano, A.
    Mosoarca, M.
    Lourenco, P. B.
    12TH INTERNATIONAL CONFERENCE ON STRUCTURAL ANALYSIS OF HISTORICAL CONSTRUCTIONS (SAHC 2021), 2021, : 3581 - 3592
  • [8] Seismic Vulnerability of Historical Constructions: A Contribution
    Oliveira, Carlos Sousa
    BULLETIN OF EARTHQUAKE ENGINEERING, 2003, 1 (01) : 37 - 82
  • [9] Seismic vulnerability of Iranian historical domes
    Hejazi, M
    EARTHQUAKE RESISTANT ENGINEERING STRUCTURES IV, 2003, 13 : 157 - 165
  • [10] Seismic Vulnerability of Historical Constructions: A Contribution
    Carlos Sousa Oliveira
    Bulletin of Earthquake Engineering, 2003, 1 : 37 - 82