Prediction of obstructive sleep apnea: comparative performance of three screening instruments on the apnea-hypopnea index and the oxygen desaturation index

被引:11
|
作者
Veugen, Christianne C. A. F. M. [1 ,2 ]
Teunissen, Emma M. [3 ]
den Otter, Leontine A. S. [4 ]
Kos, Martijn P. [5 ]
Stokroos, Robert J. [2 ]
Copper, Marcel P. [1 ,5 ]
机构
[1] St Antonius Hosp, Dept Otorhinolaryngol Head & Neck Surg, Koekoekslaan 1, NL-3435 CM Nieuwegein, Netherlands
[2] Univ Med Ctr Utrecht, Dept Otorhinolaryngol Head & Neck Surg, Heidelberglaan 100, NL-3584 CX Utrecht, Netherlands
[3] Radboud Univ Nijmegen, Med Ctr, Dept Otorhinolaryngol Head & Neck Surg, Geert Groteplein Zuid 10, NL-6525 GA Nijmegen, Netherlands
[4] Univ Med Ctr Groningen, Fac Med, Hanzepl 1, NL-9713 GZ Groningen, Netherlands
[5] Ruysdael Sleepclin, Ruysdaelstr 49 A1-D, NL-1071 XA Amsterdam, Netherlands
关键词
Obstructive sleep apnea; Polysomnography; Screening; NoSAS score; STOP-Bang questionnaire; ESS; STOP-BANG QUESTIONNAIRE; NOSAS SCORE; VALIDATION; TOOL; HYPERTENSION; SEVERITY; VERSION;
D O I
10.1007/s11325-020-02219-6
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Purpose To evaluate the performance of the NoSAS (neck, obesity, snoring, age, sex) score, the STOP-Bang (snoring, tiredness, observed apneas, blood pressure, body mass index, age, neck circumference, gender) questionnaire, and the Epworth sleepiness score (ESS) as a screening tool for obstructive sleep apnea (OSA) severity based on the apnea-hypopnea index (AHI) and the oxygen desaturation index (ODI). Methods Data from 235 patients who were monitored by ambulant polysomnography (PSG) were retrospectively analyzed. OSA severity was classified based on the AHI; similar classification categories were made based on the ODI. Discrimination was assessed by the area under the curve (AUC), while predictive parameters were calculated by four-grid contingency tables. Results The NoSAS score and the STOP-Bang questionnaire were both equally adequate screening tools for the AHI and the ODI with AUC ranging from 0.695 to 0.767 and 0.684 to 0.767, respectively. Both questionnaires perform better when used as a continuous variable. The ESS did not show adequate discrimination for screening for OSA (AUC ranging from 0.450 to 0.525). Male gender, age, and BMI proved to be the strongest individual predictors in this cohort. Conclusion This is the first study to evaluate the predictive performance of three different screening instruments with respect to both the AHI and the ODI. This is important, due to increasing evidence that the ODI may have a higher reproducibility in the clinical setting. The NoSAS score and the STOP-Bang questionnaire proved to be equally adequate to predict OSA severity based on both the AHI and the ODI.
引用
收藏
页码:1267 / 1275
页数:9
相关论文
共 50 条
  • [1] Prediction of obstructive sleep apnea: comparative performance of three screening instruments on the apnea-hypopnea index and the oxygen desaturation index
    Christianne C. A. F. M. Veugen
    Emma M. Teunissen
    Leontine A. S. den Otter
    Martijn P. Kos
    Robert J. Stokroos
    Marcel P. Copper
    Sleep and Breathing, 2021, 25 : 1267 - 1275
  • [2] A comparison between auto-scored apnea-hypopnea index and oxygen desaturation index in the characterization of positional obstructive sleep apnea
    Levendowski, Daniel J.
    Hamilton, Garun S.
    St Louis, Erik K.
    Penzel, Thomas
    Dawson, David
    Westbrook, Philip R.
    NATURE AND SCIENCE OF SLEEP, 2019, 11 : 69 - 78
  • [3] Outcome Measurements in Obstructive Sleep Apnea: Beyond the Apnea-Hypopnea Index
    Tam, Samantha
    Woodson, B. Tucker
    Rotenberg, Brian
    LARYNGOSCOPE, 2014, 124 (01): : 337 - 343
  • [4] Mean apnea-hypopnea duration (but not apnea-hypopnea index) is associated with worse hypertension in patients with obstructive sleep apnea
    Wu, Hao
    Zhan, Xiaojun
    Zhao, Mengneng
    Wei, Yongxiang
    MEDICINE, 2016, 95 (48) : e5493
  • [5] Accelerometry-derived respiratory index estimating apnea-hypopnea index for sleep apnea screening
    Bricout, Aurelien
    Fontecave-Jallon, Julie
    Pepin, Jean-Louis
    Gumery, Pierre-Yves
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2021, 207
  • [6] Tongue Volume Influences Lowest Oxygen Saturation but Not Apnea-Hypopnea Index in Obstructive Sleep Apnea
    Ahn, Sang Hyeon
    Kim, Jinna
    Min, Hyun Jin
    Chung, Hyo Jin
    Hong, Jae Min
    Lee, Jeung-Gweon
    Kim, Chang-Hoon
    Cho, Hyung-Ju
    PLOS ONE, 2015, 10 (08):
  • [7] Effect of Emphysema Severity on the Apnea-Hypopnea Index in Smokers with Obstructive Sleep Apnea
    Krachman, Samuel L.
    Tiwari, Rachna
    Vega, Maria Elena
    Yu, Daohai
    Soler, Xavier
    Jaffe, Fredric
    Kim, Victor
    Swift, Irene
    D'Alonzo, Gilbert E.
    Criner, Gerard J.
    ANNALS OF THE AMERICAN THORACIC SOCIETY, 2016, 13 (07) : 1129 - 1135
  • [8] Impact of Desaturation Patterns versus Apnea- Hypopnea Index in the Development of Cardiovascular Comorbidities in Obstructive Sleep Apnea Patients
    Blekic, Nathan
    Bold, Ionela
    Mettay, Thomas
    Bruyneel, Marie
    NATURE AND SCIENCE OF SLEEP, 2022, 14 : 1457 - 1468
  • [9] Mortality-risk-based apnea-hypopnea index thresholds for diagnostics of obstructive sleep apnea
    Korkalainen, Henri
    Toyras, Juha
    Nikkonen, Sami
    Leppanen, Timo
    JOURNAL OF SLEEP RESEARCH, 2019, 28 (06)
  • [10] Body weight and obstructive sleep apnea: a mathematical relationship between body mass index and apnea-hypopnea index in veterans
    Fattal, Deema
    Hester, Stacy
    Wendt, Linder
    JOURNAL OF CLINICAL SLEEP MEDICINE, 2022, 18 (12): : 2723 - 2729