Differences in peritoneal dialysis technique survival between patients treated with peritoneal dialysis systems from different companies

被引:13
作者
Boudville, Neil [1 ,2 ]
Ullah, Shahid [2 ]
Clayton, Phil [2 ,3 ]
Sud, Kamal [2 ,4 ,5 ,6 ]
Borlace, Monique [2 ,3 ]
Badve, Sunil V. [2 ,7 ]
Chakera, Aron [1 ,8 ]
Johnson, David W. [2 ,9 ,10 ,11 ]
机构
[1] Univ Western Australia, Med Sch, Perth, WA, Australia
[2] Australia & New Zealand Dialysis & Transplant Reg, Adelaide, SA, Australia
[3] Royal Adelaide Hosp, Cent Northern Adelaide Renal & Transplantat Serv, Adelaide, SA, Australia
[4] Nepean Hosp, Dept Renal Med, Sydney, NSW, Australia
[5] Westmead Hosp, Dept Renal Med, Sydney, NSW, Australia
[6] Univ Sydney, Med Sch, Dept Clin Med, Sydney, NSW, Australia
[7] St George Hosp, Dept Nephrol, Sydney, NSW, Australia
[8] Sir Charles Gairdner Hosp, Dept Renal Med, Perth, WA, Australia
[9] Princess Alexandra Hosp, Dept Nephrol, Brisbane, Qld, Australia
[10] Translat Res Inst, Brisbane, Qld, Australia
[11] Univ Queensland, Ctr Kidney Dis Res, Australasian Kidney Trial Network, Brisbane, Qld, Australia
关键词
chronic renal failure; dialysis; epidemiology; peritoneal dialysis; survival analysis; OPEN-LABEL TRIAL; HEMODIALYSIS; MULTICENTER;
D O I
10.1093/ndt/gfy340
中图分类号
R3 [基础医学]; R4 [临床医学];
学科分类号
1001 ; 1002 ; 100602 ;
摘要
Background A number of peritoneal dialysis (PD) systems are available but there have been few studies comparing them. The aim of this study was to examine technique failure and patient survival between different PD company systems. Methods The study included all patients who commenced PD between 1995 and 2014 in Australia and New Zealand. Groups were compared according to the initial PD company system that they received. The primary outcome was a composite of PD technique failure and death. Results A total of 16575 patients commenced PD using systems manufactured by Baxter [n=13438 (81%)], Fresenius Medical Care [n=2848 (17%)] or Gambro [n=289 (2%)]. Of these, 11870 (72%) developed technique failure, including 5421 (33%) who died. The median time to technique failure or death for all patients was 625 [interquartile range (IQR) 318-1114] days: 629.5 (IQR 321-1121) days with Baxter, 620.5 (IQR 311-1069) days with Fresenius Medical Care and 538 (IQR 272-1001) days with Gambro systems (P=0.023). There was a statistically significant increase in technique failure or mortality rates in patients on Gambro {adjusted incidence rate ratio [IRR] 1.46 [95% confidence interval (CI) 1.33-1.62]} and Fresenius [adjusted IRR 1.10 (95% CI 1.01-1.19)] systems compared with Baxter systems. No difference in patient survival was observed between the three PD systems. Conclusions PD systems manufactured by different companies may be associated with important differences in PD technique survival. This needs to be confirmed with adequately powered, prospective randomized controlled clinical trials.
引用
收藏
页码:1035 / 1044
页数:10
相关论文
共 17 条
  • [1] Magnesium and Dialysis: The Neglected Cation
    Alhosaini, Mohamad
    Leehey, David J.
    [J]. AMERICAN JOURNAL OF KIDNEY DISEASES, 2015, 66 (03) : 523 - 531
  • [2] Daugirdas JT, 2015, J VASC ACCESS
  • [3] Diaz-Buxo Jose A, 2005, Adv Perit Dial, V21, P112
  • [4] DiNicolantonio JJ, 2014, OCHSNER J, V14, P350
  • [5] Hemodialysis versus peritoneal dialysis: A comparison of adjusted mortality rates
    Fenton, SSA
    Schaubel, DE
    Desmeules, M
    Morrison, HI
    Mao, Y
    Copleston, P
    Jeffery, JR
    Kjellstrand, CM
    [J]. AMERICAN JOURNAL OF KIDNEY DISEASES, 1997, 30 (03) : 334 - 342
  • [6] HALL LJ, 1989, ADV PERIT D, V5, P227
  • [7] Hemodialysis and peritoneal dialysis: Patients' assessment of their satisfaction with therapy and the impact of the therapy on their lives
    Juergensen, Erika
    Wuerth, Diane
    Finkelstein, Susan H.
    Juergensen, Peter H.
    Bekui, Ambek
    Finkelstein, Fredric O.
    [J]. CLINICAL JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2006, 1 (06): : 1191 - 1196
  • [8] DURATION OF HEMODIALYSIS FOLLOWING PERITONEAL DIALYSIS CESSATION IN AUSTRALIA AND NEW ZEALAND: PROPOSAL FOR A STANDARDIZED DEFINITION OF TECHNIQUE FAILURE
    Lan, Patrick G.
    Clayton, Philip A.
    Johnson, David W.
    McDonald, Stephen P.
    Borlace, Monique
    Badve, Sunil V.
    Sud, Kamal
    Boudville, Neil
    [J]. PERITONEAL DIALYSIS INTERNATIONAL, 2016, 36 (06): : 623 - 630
  • [9] Changes in the worldwide epidemiology of peritoneal dialysis
    Li, Philip Kam-Tao
    Chow, Kai Ming
    Van de Luijtgaarden, Moniek W. M.
    Johnson, David W.
    Jager, Kitty J.
    Mehrotra, Rajnish
    Naicker, Sarala
    Pecoits-Filho, Roberto
    Yu, Xue Qing
    Lameire, Norbert
    [J]. NATURE REVIEWS NEPHROLOGY, 2017, 13 (02) : 90 - 103
  • [10] Comparison of clinical outcome and ease of handling in two double-bag systems in continuous ambulatory peritoneal dialysis: A prospective, randomized, controlled, multicenter study
    Li, PKT
    Law, MC
    Chow, KM
    Chan, WK
    Szeto, CC
    Cheng, YL
    Wong, TYH
    Leung, CB
    Wang, AYM
    Lui, SF
    Yu, AWY
    [J]. AMERICAN JOURNAL OF KIDNEY DISEASES, 2002, 40 (02) : 373 - 380