Radiation Dose Reduction Using a Novel Fluoroscopy System in Patients Undergoing Diagnostic Invasive Coronary Angiography

被引:4
|
作者
Kraemer, Bjoern F. [1 ]
Tesche, Christian [2 ,3 ]
Hapfelmeier, Alexander [4 ]
Finsterer, Sebastian [1 ]
Ebersberger, Ullrich [6 ]
Schluter, Mathis [1 ]
Ziegler, Martin [1 ]
Martens, Eimo [5 ]
Laugwitz, Karl-Ludwig [5 ]
Schmidt, Martin [1 ]
机构
[1] Kreisklin Ebersberg, Dept Cardiol, Ebersberg, Germany
[2] Heart Ctr Munich Bogenhausen, Dept Cardiol & Intens Care Med, Munich, Germany
[3] Ludwig Maximilians Univ Munchen, Munich Univ Clin, Dept Cardiol, Munich, Germany
[4] Tech Univ Munich, Klinikum Rechts Isar, Inst Med Informat Stat & Epidemiol, Munich, Germany
[5] Tech Univ Munich, Klinikum Rechts Isar, Dept Cardiol, Munich, Germany
[6] Kardiol Munchen Nord, Munich, Germany
关键词
invasive coronary angiography; interventional cardiology; radiation dose; dose area product;
D O I
10.1097/RTI.0000000000000510
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Invasive coronary angiography (ICA) still causes a significant amount of radiation exposure for patients and operators. In February 2017, the Azurion system was introduced, a new-generation fluoroscopy image acquisition and processing system. Radiation exposure in patients undergoing ICA was assessed comparing the novel Azurion 7 F12 angiography system to its predecessor Allura Xper in a randomized manner. Methods: Radiation exposure was prospectively analyzed in 238 patients undergoing diagnostic ICA. Patients were randomly assigned to the novel Azurion system (119 patients) or its predecessor Allura Xper system (119 patients). In each patient, 8 predefined standard projections (5 left coronary artery, 3 right coronary artery) were performed. Image quality was quantified by grading of the images on the basis of a 5-point grading system. Results: Radiation dose area product was significantly lower in the Azurion group 109 (interquartile range [IQR 75-176] cGy cm(2)) compared with the Allura Xper group 208 [IQR 134-301] cGy cm(2) (P<0.001). Body mass index (26.6 [IQR 23.9-29.7] kg/m(2) vs. 26.2 [IQR 24.2-29.4] kg/m(2); P=0.607), body surface area (1.96 [IQR 1.81-2.11] m(2) vs. 1.90 [IQR 1.77-20.4] m(2); P=0.092), and procedure duration (1.5 [IQR 1.2-2.3] min vs. 1.6 [IQR 1.2-2.5] min; P=0.419) were similar in both groups. Images from the Azurion system were at least of equal quality compared with Allura Xper (image quality grade 4.82 +/- 0.45 vs. 4.75 +/- 0.52, P=0.43). Conclusion: Use of the novel Azurion 7 F12 angiography system resulted in a significant reduction of dose area product in patients undergoing diagnostic ICA by 56%.
引用
收藏
页码:52 / 56
页数:5
相关论文
共 50 条
  • [1] Importance of fluoroscopy in the radiation dose for coronary angiography.
    Pezzano, M
    Jacq, L
    Caussin, C
    Habis, M
    Schaison, F
    Verdaguer, M
    Sangare, A
    Bouquet, F
    Lardoux, H
    AMERICAN JOURNAL OF CARDIOLOGY, 2001, 88 (5A): : 124G - 125G
  • [2] Marked Reduction of Effective Radiation Dose in Patients Undergoing CT Coronary Angiography using Prospective ECG Gating
    Freeman, Anthony
    Learner, Ruth
    Eggleton, Simon
    Lambros, John
    Friedman, Daniel
    HEART LUNG AND CIRCULATION, 2011, 20 (08): : 512 - 516
  • [3] Radiation dose to the paediatric undergoing diagnostic coronary angiography and percutaneous intervention procedures
    Abuzaid, M.
    Abdelrazig, A.
    Sulieman, A.
    Alkhorayef, M.
    Babikir, E.
    Alonazi, B.
    Bradley, D. A.
    RADIATION PHYSICS AND CHEMISTRY, 2020, 167
  • [4] Significant Radiation Dose Reduction Using a Novel Angiography Platform in Patients Undergoing Cryoballoon Pulmonary Vein Isolation
    Schmidt, Martin
    Tesche, Christian
    Hapfelmeier, Alexander
    Finsterer, Sebastian
    Valassis, Gregorius
    Ebersberger, Ullrich
    Schlueter, Mathis
    Ziegler, Martin
    Kraemer, Bjoern F.
    JOURNAL OF THORACIC IMAGING, 2020, 35 (03) : 167 - 172
  • [5] Radiation Dose and Fluoroscopy Time of Diagnostic Angiography in Patients with Spinal Dural Arteriovenous Fistula
    Yigit Ozpeynirci
    Christoph Trumm
    Robert Stahl
    David Fischer
    Thomas Liebig
    Robert Forbrig
    Clinical Neuroradiology, 2022, 32 : 791 - 797
  • [6] Reduction of radiation dose in pediatric patients using pulsed fluoroscopy
    Hernandez, RJ
    Goodsitt, MM
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 167 (05) : 1247 - 1253
  • [7] Radiation Dose and Fluoroscopy Time of Diagnostic Angiography in Patients with Spinal Dural Arteriovenous Fistula
    Ozpeynirci, Yigit
    Trumm, Christoph
    Stahl, Robert
    Fischer, David
    Liebig, Thomas
    Forbrig, Robert
    CLINICAL NEURORADIOLOGY, 2022, 32 (03) : 791 - 797
  • [8] Reducing Radiation Dose in Coronary Angiography and Angioplasty Using Dose Reduction Protocol
    Yaduvanshi, Amitabh
    Yaduvanshi, Ishita
    Bhagwati, Mohit M.
    Kataria, Vikas
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2023, 81 (16) : S54 - S54
  • [9] Radiation dose reduction in CT coronary angiography
    Shapiro B.P.
    Young P.M.
    Kantor B.
    Choe Y.H.
    McCollough C.H.
    Gerber T.C.
    Current Cardiology Reports, 2010, 12 (1) : 59 - 67
  • [10] Reduction of radiation delivered to patients undergoing invasive coronary procedures. Effect of a programme for dose reduction based on radiation-protection training
    Georges, Jean-Louis
    Livarek, Bernard
    Gibault-Genty, Geraldine
    Aziza, Jean-Paul
    Hautecoeur, Jean-Louis
    Soleille, Henry
    Messaoudi, Hela
    Annabi, Nizar
    Kebsi, Mohammed Al
    ARCHIVES OF CARDIOVASCULAR DISEASES, 2009, 102 (12) : 821 - 827