Accurate Estimation of the Duration of Testicular Ischemia Using Creatine Chemical Exchange Saturation Transfer (CrCEST) Imaging

被引:5
作者
Takahashi, Yusuke [1 ,2 ]
Kioka, Hidetaka [1 ]
Saito, Shigeyoshi [3 ,4 ]
Fukuhara, Shinichiro [5 ]
Asano, Yoshihiro [1 ]
Takashima, Seiji [6 ]
Yoshioka, Yoshichika [7 ,8 ,9 ]
Sakata, Yasushi [1 ]
机构
[1] Osaka Univ, Dept Cardiovasc Med, Grad Sch Med, Suita, Osaka 5650871, Japan
[2] Natl Cerebral & Cardiovasc Ctr, Dept Mol Pharmacol, Res Inst, Suita, Osaka, Japan
[3] Osaka Univ, Dept Med Phys & Engn, Div Hlth Sci, Grad Sch Med, Suita, Osaka, Japan
[4] Natl Cardiovasc & Cerebral Res Ctr, Dept Biomed Imaging, Suita, Osaka, Japan
[5] Osaka Univ, Dept Urol, Grad Sch Med, Suita, Osaka, Japan
[6] Osaka Univ, Dept Med Biochem, Grad Sch Frontier Biosci, Suita, Osaka, Japan
[7] Osaka Univ, Grad Sch Frontier Biosci, Lab Biofunct Imaging, Suita, Osaka, Japan
[8] Osaka Univ, Ctr Informat & Neural Networks CiNet, Suita, Osaka, Japan
[9] Informat & Commun Technol NICT, Suita, Osaka, Japan
关键词
testicular ischemia; chemical exchange saturation transfer; magnetic resonance imaging; creatine; CEST MRI; TESTES; TORSION; PHOSPHOCREATINE; SPECTROSCOPY; GLIOMAS; MICE;
D O I
10.1002/jmri.27456
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background In the management of testicular torsion, estimating the duration of testicular ischemia is essential for deciding on an appropriate surgical treatment, but there are currently limited evaluation methods. Purpose To perform testicular creatine chemical exchange saturation transfer (CrCEST) imaging and to evaluate its ability to accurately estimate the duration of testicular ischemia. Study Type Prospective. Animal Model C57BL/6 control mice (n = 6) and testicular ischemia models induced by clamping the spermatic cord (n = 14). Eight of testicular ischemia models were serially imaged at two or three timepoints and a total of 26 images of ischemic testis were obtained. The ischemic duration ranged from 6-42 hours. Field Strength/Sequence 11.7T vertical-bore MRI/segment fast low-angle shot acquisition for CEST. Assessment CrCEST imaging was performed and the magnetization transfer ratio for the CrCEST effect (MTRCr**) was calculated in control mice and testicular ischemia models. Correlation analysis between the duration of testicular ischemia and MTRCr** decline was performed. Statistical Tests Paired t-test, and Pearson's correlation analysis. Results In control mice, the CrCEST effect in testes was significantly more than five times higher than that in skeletal muscle. MTRCr** did not differ significantly between the right and left testes (8.6 +/- 0.8 vs. 8.3 +/- 0.6, P = 0.96). In testicular ischemia models, MTRCr** of ischemic testes was significantly lower than that of controls (4 +/- 2 vs. 8.9 +/- 0.6, P < 0.001). Correlation analysis revealed a strong linear correlation between MTRCr** decline and the duration of ischemia (r = 0.96, P < 0.001). Data Conclusion A decreased CrCEST effect in ischemic testes correlated well with ischemic duration. Testicular CrCEST imaging was useful for accurately estimating the duration of testicular ischemia. Level of Evidence 2 Technical Efficacy Stage 2
引用
收藏
页码:1559 / 1567
页数:9
相关论文
共 50 条
[41]   Chemical Exchange Saturation Transfer (CEST) Imaging With Fast Variably-accelerated Sensitivity Encoding (vSENSE) [J].
Zhang, Yi ;
Heo, Hye-Young ;
Lee, Dong-Hoon ;
Jiang, Shanshan ;
Zhao, Xuna ;
Bottomley, Paul A. ;
Zhou, Jinyuan .
MAGNETIC RESONANCE IN MEDICINE, 2017, 77 (06) :2225-2238
[42]   Characterization of viscosupplementation formulations using chemical exchange saturation transfer (ViscoCEST) [J].
Mohammad Haris ;
Anup Singh ;
Sanjana Reddy ;
Puneet Bagga ;
J. Bruce Kneeland ;
Fotios P. Tjoumakaris ;
Hari Hariharan ;
Francesco M. Marincola ;
Ravinder Reddy .
Journal of Translational Medicine, 14
[43]   Regional Mapping of Brain Glutamate Distributions Using Glutamate-Weighted Chemical Exchange Saturation Transfer Imaging [J].
Lee, Do-Wan ;
Woo, Chul-Woong ;
Woo, Dong-Cheol ;
Kim, Jeong Kon ;
Kim, Kyung Won ;
Lee, Dong-Hoon .
DIAGNOSTICS, 2020, 10 (08)
[44]   Frequency importance analysis for chemical exchange saturation transfer magnetic resonance imaging using permuted random forest [J].
Chen, Yibing ;
Dang, Xujian ;
Zhao, Benqi ;
Chen, Zhensen ;
Zhao, Yingcheng ;
Zhao, Fengjun ;
Zheng, Zhuozhao ;
He, Xiaowei ;
Peng, Jinye ;
Song, Xiaolei .
NMR IN BIOMEDICINE, 2023, 36 (06)
[45]   Biochemical imaging of cervical intervertebral discs with glycosaminoglycan chemical exchange saturation transfer magnetic resonance imaging: feasibility and initial results [J].
Schleich, Christoph ;
Mueller-Lutz, Anja ;
Zimmermann, Lisa ;
Boos, Johannes ;
Schmitt, Benjamin ;
Wittsack, Hans-Joerg ;
Antoch, Gerald ;
Miese, Falk .
SKELETAL RADIOLOGY, 2016, 45 (01) :79-85
[46]   Demonstration of pH imaging in acute stroke with endogenous ratiometric chemical exchange saturation transfer magnetic resonance imaging at 2 ppm [J].
Wu, Yin ;
Sun, Phillip Zhe .
NMR IN BIOMEDICINE, 2023, 36 (03)
[47]   Biochemical imaging of cervical intervertebral discs with glycosaminoglycan chemical exchange saturation transfer magnetic resonance imaging: feasibility and initial results [J].
Christoph Schleich ;
Anja Müller-Lutz ;
Lisa Zimmermann ;
Johannes Boos ;
Benjamin Schmitt ;
Hans-Jörg Wittsack ;
Gerald Antoch ;
Falk Miese .
Skeletal Radiology, 2016, 45 :79-85
[48]   Chemical exchange saturation transfer MR imaging of Parkinson’s disease at 3 Tesla [J].
Chunmei Li ;
Shuai Peng ;
Rui Wang ;
Haibo Chen ;
Wen Su ;
Xuna Zhao ;
Jinyuan Zhou ;
Min Chen .
European Radiology, 2014, 24 :2631-2639
[49]   Chemical exchange saturation transfer MR imaging of Parkinson's disease at 3 Tesla [J].
Li, Chunmei ;
Peng, Shuai ;
Wang, Rui ;
Chen, Haibo ;
Su, Wen ;
Zhao, Xuna ;
Zhou, Jinyuan ;
Chen, Min .
EUROPEAN RADIOLOGY, 2014, 24 (10) :2631-2639
[50]   Detection of tissue pH with quantitative chemical exchange saturation transfer magnetic resonance imaging [J].
Igarashi, Takahiro ;
Kim, Hahnsung ;
Sun, Phillip Zhe .
NMR IN BIOMEDICINE, 2023, 36 (06)