Improvement of time measurement with the INO-ICAL resistive plate chambers

被引:6
|
作者
Bhatt, A. D. [1 ]
Datar, V. M. [1 ]
Majumder, G. [1 ]
Mondal, N. K. [1 ]
Pathaleswar [1 ]
Satyanarayana, B. [1 ]
机构
[1] Tata Inst Fundamental Res, Homi Bhabha Rd, Bombay 400005, Maharashtra, India
来源
JOURNAL OF INSTRUMENTATION | 2016年 / 11卷
关键词
Resistive-plate chambers; Timing detectors; Particle tracking detectors (Gaseous detectors);
D O I
10.1088/1748-0221/11/11/C11001
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
There are many sources of position dependent variation of the intrinsic gain of a single gap RPC, e.g. variation of the thickness of the glass electrodes, the buttons and spacers, different composition of the gas mixture due to improper gas flow, leakage etc. One of the dominant components of the time resolution of a large area single gap RPC is this position dependent gain. Also, there is a variation of timing information as a function of the strip multiplicity as well as the lateral position of the trajectory in the RPC strip coordinate. This paper describes the technique of offline time correction to achieve a time resolution better than a ns. This technique is validated using a large cosmic ray dataset collected with a stack of twelve, 1 x 1m(2) RPCs at TIFR. This paper also mentions a few alternate solutions to improve the time resolution during the operational phase of the INO-ICAL experiment. All these solutions are not only valid for INO, but also for any experiment with large RPC detectors.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Numerical studies on electrostatic field configuration of Resistive Plate Chambers for the INO-ICAL experiment
    Jash, A.
    Majumdar, N.
    Mukhopadhyay, S.
    Chattopadhyay, S.
    JOURNAL OF INSTRUMENTATION, 2015, 10
  • [2] Numerical qualification of eco-friendly gas mixtures for avalanche-mode operation of resistive plate chambers in INO-ICAL
    Datta, J.
    Tripathy, S.
    Majumdar, N.
    Mukhopadhyay, S.
    JOURNAL OF INSTRUMENTATION, 2021, 16 (07)
  • [3] Update of INO-ICAL reconstruction algorithm
    Seth, S.
    Bhatt, A.
    Majumder, G.
    Mishra, A.
    JOURNAL OF INSTRUMENTATION, 2018, 13
  • [4] Outgassing and leak test of INO-ICAL RPC detectors
    Phogat, A.
    Ahmad, R.
    Kumar, H.
    Ahmed, A.
    Kumar, A.
    Naimuddin, Md
    JOURNAL OF INSTRUMENTATION, 2020, 15 (10):
  • [5] RPC detector characteristics and performance for INO-ICAL experiment
    Kumar, A.
    Gaur, A.
    Hasbuddin, Md.
    Naimuddin, Md.
    JOURNAL OF INSTRUMENTATION, 2016, 11
  • [6] Development of glass resistive plate chambers for INO experiment
    Datar, V. M.
    Jena, Satyajit
    Kalmani, S. D.
    Mondal, N. K.
    Nagaraj, P.
    Reddy, L. V.
    Saraf, M.
    Satyanarayana, B.
    Shinde, R. R.
    Verma, P.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 602 (03): : 744 - 748
  • [7] Development and commissioning of the HARDROC based readout for the INO-ICAL experiment
    Kumar, Ashok
    Gaur, Ankit
    Phogat, Aman
    Rafik, Md.
    Naimuddin, Md.
    JOURNAL OF INSTRUMENTATION, 2016, 11
  • [8] Study of RPC bakelite electrodes and detector performance for INO-ICAL
    Kumar, A.
    Gaur, A.
    Hasbuddin, Md.
    Kumar, P.
    Kumar, P.
    Kaur, D.
    Mishra, S.
    Naimuddin, Md.
    JOURNAL OF INSTRUMENTATION, 2014, 9
  • [9] New front-end electronics for INO-ICAL experiment
    Phogat, Aman
    Gaur, Ankit
    Rafik, Moh
    Kumar, Ashok
    Naimuddin, Md
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 905 : 193 - 198
  • [10] Characterisation of glass electrodes and RPC detectors for INO-ICAL experiment
    Naimuddin, Md.
    Kaur, D.
    Kumar, P.
    Gaur, A.
    Kumar, P.
    Hasbuddin, Md.
    Mishra, S.
    Kumar, A.