Quality specifications for biochemical markers of myocardial injury

被引:19
|
作者
Zaninotto, M [1 ]
Mion, M [1 ]
Altinier, S [1 ]
Forni, M [1 ]
Plebani, M [1 ]
机构
[1] UNiv Hosp Padova, Azienda Osped Padova, Dept Lab Med, I-35128 Padua, Italy
关键词
troponin I; troponin T; acute coronary syndrome; heterophilic antibodies; macrocomplex;
D O I
10.1016/j.cccn.2004.02.035
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: The current approach to the diagnosis and monitoring of myocardial damage, recognizes to biochemical markers, and in particular to troponins, a key role being well demonstrated that all elevated values were associated with a worsened prognosis. In 2001, the IFCC Committee on Standardization of Markers of Cardiac Damage published guidelines addressing the quality specifications for troponin assays in order to guarantee an analytical performance satisfying medical requirements and to standardize the quality of commercial methods. We describe how the application of quality specifications may be useful in daily practice, in order to provide advice to clinicians in the investigations of complex clinical cases of patients suffering from myocardial damage. Materials and methods: The samples from three patients (cases 1-3) admitted to the hospital with symptoms suggestive of cardiac disease, showing high troponin I (cTnI) values not correlated with clinical condition, were investigated in order to verify the accuracy of the laboratory data. The standard of quality specifications related to assay specificity, imprecision and interferences were evaluated using different platforms for cTnI assays, carrying out imprecision profile and specific studies on more common interferents in immunoassays. Results: The obtained results allow us to demonstrate two cases of false-positive cTnI values attributable to a macrocomplex between a modified "in vivo" cTnI and immunoglobulin G (case 1) and to a presence of heterophilic antibodies affecting the RxL Dimension procedure (case 3). Instead, the accuracy of data obtained in case 2 was evidenced by the imprecision profile obtained in our laboratory and by the comparison of results between different laboratories using same platform. Conclusions: The lack of standardization as well as the wide differences in the development of each assay give rise to major concerns regarding cTnI determinations. The laboratory must therefore check the compliance between the analytical characteristics of the method utilised against recommended quality specifications for a reliable understanding of the frequency of false-positive results as well as other serious analytical errors. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:65 / 72
页数:8
相关论文
共 50 条
  • [11] Biochemical markers of acute myocardial infarction: strategies for improving their clinical usefulness
    Katz, IA
    Irwig, L
    Vinen, JD
    March, L
    Wyndham, LE
    Luu, T
    Nelson, GIC
    ANNALS OF CLINICAL BIOCHEMISTRY, 1998, 35 : 393 - 399
  • [12] Quality specifications for cardiac troponin assays
    Panteghini, M
    Gerhardt, W
    Apple, FS
    Dati, F
    Ravkilde, J
    Wu, AH
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2001, 39 (02) : 175 - 179
  • [13] Cardiac troponin as biochemical marker of perinatal asphyxia and hypoxic myocardial injury
    Simovic, Aleksandra M.
    Knezevic, Jasmina
    Igrutinovic, Zoran
    Stojanovic, Nadezda
    Kocic, Sanja
    VOJNOSANITETSKI PREGLED, 2009, 66 (11) : 881 - 886
  • [14] A STUDY OF BIOCHEMICAL MARKERS OF REPERFUSION EARLY AFTER THROMBOLYSIS FOR ACUTE MYOCARDIAL-INFARCTION
    LAPERCHE, T
    STEG, PG
    DEHOUX, M
    BENESSIANO, J
    GROLLIER, G
    ALIOT, E
    MOSSARD, JM
    AUBRY, P
    COISNE, D
    HANSSEN, M
    ILIOU, MC
    CIRCULATION, 1995, 92 (08) : 2079 - 2086
  • [15] Biochemical markers in the diagnosis of coronary artery disease
    Hartmann, F
    Kampmann, M
    Frey, N
    Muller-Bardorff, M
    Katus, HA
    EUROPEAN HEART JOURNAL, 1998, 19 : N2 - N7
  • [16] Release of markers of myocardial and endothelial injury following cold cardioplegic arrest in pigs
    Valen, G
    Sellei, P
    Owall, A
    Eriksson, E
    Kallner, A
    Waldum, H
    Risberg, B
    Vaage, J
    SCANDINAVIAN CARDIOVASCULAR JOURNAL, 1997, 31 (01) : 45 - 50
  • [17] Effect of ischaemic postconditioning on markers of myocardial injury in ST-elevation myocardial infarction: a meta-analysis
    Bergman, Idan
    Gelikas, Shaul
    Wexler, Yehuda
    Braver, Omri
    Boyle, Dennis
    Nussinovitch, Udi
    OPEN HEART, 2024, 11 (01):
  • [18] Myocardial injury in noncardiac surgery
    Park, Jungchan
    Lee, Jong-Hwan
    KOREAN JOURNAL OF ANESTHESIOLOGY, 2022, 75 (01) : 4 - 11
  • [19] COMPARISON OF DIFFERENT BIOCHEMICAL MARKERS ON RAT MYOCARDIAL ISCHEMIA NECROSIS MODEL INDUCED BY ISOPROTERENOL (ISO)
    Yang, Mengsi
    Feng, Jun
    Zhang, Jing
    Tang, Shengxing
    Gui, Yingjing
    ACTA MEDICA MEDITERRANEA, 2020, 36 (02): : 871 - 876
  • [20] Cardiac decompensation during an ischemic event weakens the predictive power of myocardial injury markers
    Porela, P
    Helenius, H
    Pulkki, K
    Peltola, O
    Hänninen, KP
    Pettersson, K
    Wacker, M
    Voipio-Pulkki, LM
    CLINICA CHIMICA ACTA, 2000, 302 (1-2) : 133 - 144