Three-dimensional Radial Active Contour Model: A 3-D to 1-D Image Segmentation Technique

被引:2
作者
Almeida, T. M. D. [1 ]
Cortez, P. C. [1 ]
Cavalcante, T. D. S. [2 ]
机构
[1] Univ Fed Ceara, Fortaleza, CE, Brazil
[2] Inst Fed Ceara IFCE, Sobral, CE, Brazil
关键词
Active Contour; Active Rays; Radial Snakes; 3D Segmentation; SNAKES; RAYS;
D O I
10.1109/TLA.2017.7854634
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In this paper we present a new technique of 3D volume segmentation to be applied in general 3D shapes. This technique, called Three-dimensional Radial Active Contour Model (3D Radial Snakes), generalize the concept of Active Rays and use the idea of rays coming from a central point inside an object of interest to be segmented. This rays lies among a 3D space and are represented by two angles and it's length. The idea of this model is to achieve the edge of the object of interest by the analysis of the information only on the ray (1D). We perform tests in synthetic 3D shapes varying the number of rays and computing the mean distance from the original shape and calculating how similar the shapes are. We calculate the processing time by segmentation cycles and compare against 3D Region Growing technique. The obtained results from synthetic volumes show that this method can be applied in image segmentation with good accuracy in a very fast way.
引用
收藏
页码:365 / 373
页数:9
相关论文
共 26 条
[1]  
Alexandria A. R., 2010, 17 INT C SYST SIGN I, P81
[2]  
[Anonymous], 2009, PEARSON ED INDIA
[3]   B-spline active rays segmentation of microcalcifications in mammography [J].
Arikidis, Nikolaos S. ;
Skiadopoulos, Spyros ;
Karahaliou, Anna ;
Likaki, Eleni ;
Panayiotakis, George ;
Costaridou, Lena .
MEDICAL PHYSICS, 2008, 35 (11) :5161-5171
[4]   Radial snakes: Comparison of segmentation methods in synthetic noisy images [J].
Bessa, Jessyca Almeida ;
Cortez, Paulo Cesar ;
da Silva Felix, John Hebert ;
da Rocha Neto, Ajalmar Rego ;
de Alexandria, Auzuir Ripardo .
EXPERT SYSTEMS WITH APPLICATIONS, 2015, 42 (06) :3079-3088
[5]   AUTOMATIC COMPUTER-PROCESSING OF DIGITAL TWO-DIMENSIONAL ECHOCARDIOGRAMS [J].
BUDA, AJ ;
DELP, EJ ;
MEYER, CR ;
JENKINS, JM ;
SMITH, DN ;
BOOKSTEIN, FL ;
PITT, B .
AMERICAN JOURNAL OF CARDIOLOGY, 1983, 52 (03) :384-389
[6]  
Cavalcante T S., 2016, THESIS
[7]   Active contours without edges [J].
Chan, TF ;
Vese, LA .
IEEE TRANSACTIONS ON IMAGE PROCESSING, 2001, 10 (02) :266-277
[8]   ON ACTIVE CONTOUR MODELS AND BALLOONS [J].
COHEN, LD .
CVGIP-IMAGE UNDERSTANDING, 1991, 53 (02) :211-218
[9]   FINITE-ELEMENT METHODS FOR ACTIVE CONTOUR MODELS AND BALLOONS FOR 2-D AND 3-D IMAGES [J].
COHEN, LD ;
COHEN, I .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1993, 15 (11) :1131-1147
[10]   pSnakes: A new radial active contour model and its application in the segmentation of the left ventricle from echocardiographic images [J].
de Alexandria, Auzuir Ripardo ;
Cortez, Paulo Cesar ;
Bessa, Jessyca Almeida ;
da Silva Felix, John Hebert ;
de Abreu, Jose Sebastiao ;
de Albuquerque, Victor Hugo C. .
COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2014, 116 (03) :260-273