Pulpal Effects of Enamel Ablation With a Microsecond Pulsed λ=9.3-μm CO2 Laser

被引:19
作者
Staninec, Michal [1 ]
Darling, Cynthia L. [1 ]
Goodis, Harold E. [1 ]
Pierre, Daniel [1 ]
Cox, Darren P. [2 ]
Fan, Kenneth [1 ]
Larson, Michael [1 ]
Parisi, Renaldo [1 ]
Hsu, Dennis [1 ]
Manesh, Saman K. [1 ]
Ho, Chi [1 ]
Hosseini, Mehran [3 ]
Fried, Daniel [1 ]
机构
[1] Univ Calif San Francisco, Sch Dent, Dept Prevent & Restorat Dent Sci, San Francisco, CA 94143 USA
[2] Univ Calif San Francisco, Sch Dent, Dept Orofacial Sci & Pathol, San Francisco, CA 94143 USA
[3] Univ Calif San Francisco, Sch Dent, Dept Oral & Maxillofacial Surg, San Francisco, CA 94143 USA
关键词
CO2; laser; laser ablation; enamel; dental pulp; temperature measurements; 9.6; MU-M; DENTAL ENAMEL; BONE-ABLATION; INHIBITION; LASERS; CARIES; ULTRASTRUCTURE; IRRADIATION; MECHANISM; STRENGTH;
D O I
10.1002/lsm.20748
中图分类号
R75 [皮肤病学与性病学];
学科分类号
100206 ;
摘要
Background and Objectives: In vitro studies have shown that CO2 lasers operating at the highly absorbed 9.3 and 9.6-mu m wavelengths with a pulse duration in the range of 10-20-microsecond are well suited for the efficient ablation of enamel and dentin with minimal peripheral thermal damage. Even though these CO2 lasers are highly promising, they have yet to receive FDA approval. Clinical studies are necessary to determine if excessive heat deposition in the tooth may have any detrimental pulpal effects, particularly at higher ablative fluencies. The purpose of this study was to evaluate the pulpal safety of laser irradiation of tooth occlusal surfaces under the conditions required for small conservative preparations confined to enamel. Study Design/Materials and Methods: Test subjects requiring removal of third molar teeth were recruited and teeth scheduled for extraction were irradiated using a pulsed CO2 laser at a wavelength of 9.3 pm operating at 25 or 50 Hz using a incident fluence of 20 J/cm(2) for a total of 3,000 laser pulses (36 J) for both rates with water cooling. Two control groups were used, one with no treatment and one with a small cut made with a conventional high-speed hand-piece. No anesthetic was used for any of the procedures and tooth vitality was evaluated prior to treatment by heat, cold and electrical testing. Short term effects were observed on teeth extracted within 72 hours after treatment and long term effects were observed on teeth extracted 90 days after treatment. The pulps of the teeth were fixed with formalin immediately after extraction and subjected to histological examination. Additionally, micro-thermocouple measurements were used to estimate the potential temperature rise in the pulp chamber of extracted teeth employing the same irradiation conditions used in vivo. Results: Pulpal thermocouple measurements showed the internal temperature rise in the tooth was within safe limits, 3.3 +/- 1.4 degrees C without water cooling versus 1.7 +/- 1.6 degrees C with water-cooling, n = 25, P<0.05. None of the control or treatment groups showed any deleterious effects on pulpal tissues and none of the 29 test-subjects felt pain or discomfort after the procedure. Only two test-subjects felt discomfort from "cold sensitivity" during the procedure caused by the water-spray. Conclusion: It appears that this CO2 laser can ablate enamel safely without harming the pulp under the rate of energy deposition employed in this study. Lasers Surg. Med. 41:256-263, 2009. (C) 2009 Wiley-Liss, Inc.
引用
收藏
页码:256 / 263
页数:8
相关论文
共 49 条
  • [1] [Anonymous], 1998, PRESERVATION RESTORA
  • [2] Non-destructive assessment of inhibition of demineralization in dental enamel irradiated by a λ=9.3-μm CO2 laser at ablative irradiation intensities with PS-OCT
    Can, Anna M.
    Darling, Cynthia L.
    Ho, Chi
    Fried, Daniel
    [J]. LASERS IN SURGERY AND MEDICINE, 2008, 40 (05) : 342 - 349
  • [3] CHENG JY, 2006, P SPIE, V6137
  • [4] SHEAR-STRENGTH OF COMPOSITE BONDED TO LASER-PRETREATED DENTIN
    COOPER, LF
    MYERS, ML
    NELSON, DGA
    MOWERY, AS
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 1988, 60 (01) : 45 - 49
  • [5] Real-time near IR (1310 nm) imaging of CO2 laser ablation of enamel
    Darling, Cynthia L.
    Fried, Daniel
    [J]. OPTICS EXPRESS, 2008, 16 (04): : 2685 - 2693
  • [6] Peripheral thermal and mechanical damage to dentin with microsecond and sub-microsecond 9.6 μm, 2.79 μm, and 0.355 μm laser pulses
    Dela Rosa, A
    Sarma, AV
    Le, CQ
    Jones, RS
    Fried, D
    [J]. LASERS IN SURGERY AND MEDICINE, 2004, 35 (03) : 214 - 228
  • [7] ERTL T, 1993, P SOC PHOTO-OPT INS, V1880, P176, DOI 10.1117/12.148321
  • [8] Rapid and conservative ablation and modification of enamel, dentin, and alveolar bone using a high repetition rate transverse excited atmospheric pressure CO2 laser operating at λ=9.3 μm
    Fan, Kenneth
    Bell, Paul
    Fried, Daniel
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2006, 11 (06)
  • [9] Featherstone J D, 1987, Adv Dent Res, V1, P21
  • [10] FEATHERSTONE JDB, 1995, P SOC PHOTO-OPT INS, V2394, P57, DOI 10.1117/12.207457