Sparing of tissue by using micro-slit-beam radiation therapy reduces neurotoxicity compared with broad-beam radiation therapy

被引:21
|
作者
Mukumoto, Naritoshi [1 ]
Nakayama, Masao [1 ]
Akasaka, Hiroaki [1 ]
Shimizu, Yasuyuki [1 ]
Osuga, Saki [1 ]
Miyawaki, Daisuke [1 ]
Yoshida, Kenji [1 ]
Ejima, Yasuo [1 ]
Miura, Yasushi [2 ]
Umetani, Keiji [3 ]
Kondoh, Takeshi [4 ]
Sasaki, Ryohei [1 ]
机构
[1] Kobe Univ, Grad Sch Med, Div Radiat Oncol, Chuou Ku, 7-5-2 Kusunokicho, Kobe, Hyogo 6500017, Japan
[2] Kobe Univ, Grad Sch Hlth Sci, Dept Rehabil Sci, Kobe, Hyogo, Japan
[3] Japan Synchrotron Radiat Res Inst, Sayo, Hyogo, Japan
[4] Shinsuma Hosp, Dept Neurosurg, Kobe, Hyogo, Japan
关键词
microbeam; slit beam; synchrotron radiation; neurotoxicity; radiation therapy; CENTRAL-NERVOUS-SYSTEM; IN-VIVO; X-RAYS; STEREOTACTIC RADIOSURGERY; SYNCHROTRON-RADIATION; BRAIN RADIONECROSIS; MICROPLANAR BEAMS; RADIOTHERAPY; GLIOSARCOMAS; IRRADIATION;
D O I
10.1093/jrr/rrw065
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Micro-slit-beam radiation therapy (MRT) using synchrotron-generated X-ray beams allows for extremely high-dose irradiation. However, the toxicity of MRT in central nervous system (CNS) use is still unknown. To gather baseline toxicological data, we evaluated mortality in normal mice following CNS-targeted MRT. Male C57BL/6 J mice were head-fixed in a stereotaxic frame. Synchrotron X-ray-beam radiation was provided by the SPring-8 BL28B2 beam-line. For MRT, radiation was delivered to groups of mice in a 10 x 12 mm unidirectional array consisting of 25-mu m-wide beams spaced 100, 200 or 300 mu m apart; another group of mice received the equivalent broad-beam radiation therapy (BRT) for comparison. Peak and valley dose rates of the MRT were 120 and 0.7 Gy/s, respectively. Delivered doses were 96-960 Gy for MRT, and 24-120 Gy for BRT. Mortality was monitored for 90 days post-irradiation. Brain tissue was stained using hematoxylin and eosin to evaluate neural structure. Demyelination was evaluated by Kluver-Barrera staining. The LD50 and LD100 when using MRT were 600 Gy and 720 Gy, respectively, and when using BRT they were 80 Gy and 96 Gy, respectively. In MRT, mortality decreased as the center-to-center beam spacing increased from 100 mu m to 300 mu m. Cortical architecture was well preserved in MRT, whereas BRT induced various degrees of cerebral hemorrhage and demyelination. MRT was able to deliver extremely high doses of radiation, while still minimizing neuronal death. The valley doses, influenced by beam spacing and irradiated dose, could represent important survival factors for MRT.
引用
收藏
页码:17 / 23
页数:7
相关论文
共 50 条
  • [1] Intraoperative Radiation Therapy (IORT) Combined with External Beam Radiation Therapy after Limb Sparing Surgery in Extremity Soft Tissue Sarcoma
    Roeder, F.
    Saleh-Ebrahimi, L.
    Habl, G.
    Hensley, F. W.
    Weitz, J.
    Lehner, B.
    Huber, P. E.
    Debus, J.
    Bischof, M.
    Krempien, R.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (02): : S683 - S683
  • [2] Survival Analysis of F98 Glioma Rat Cells Following Minibeam or Broad-Beam Synchrotron Radiation Therapy
    Silvia Gil
    Sukhéna Sarun
    Albert Biete
    Yolanda Prezado
    Manel Sabés
    Radiation Oncology, 6
  • [3] Survival Analysis of F98 Glioma Rat Cells Following Minibeam or Broad-Beam Synchrotron Radiation Therapy
    Gil, Silvia
    Sarun, Sukhena
    Biete, Albert
    Prezado, Yolanda
    Sabes, Manel
    RADIATION ONCOLOGY, 2011, 6
  • [4] Proton beam radiation therapy
    MacDonald, SM
    DeLaney, TF
    Loeffler, JS
    CANCER INVESTIGATION, 2006, 24 (02) : 199 - 208
  • [5] Functional Characterisation of Novel Silicon Beam Monitors for the Micro-beam Radiation Therapy
    Povoli, Marco
    Alagoz, E.
    Bravin, A.
    Cornelius, I.
    Braeuer-Krisch, E.
    Fournier, P.
    Hansen, T. E.
    Kok, A.
    Lerch, M.
    Monakhov, E.
    Morse, J.
    Petasecca, M.
    Requardt, H.
    Rosenfeld, A. B.
    Rohrich, D.
    Salome, M.
    Sandaker, H.
    Stugu, B.
    2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2015,
  • [6] Thin silicon strip detectors for beam monitoring in Micro-beam Radiation Therapy
    Povoli, M.
    Alagoz, E.
    Bravin, A.
    Cornelius, I.
    Braeuer-Krisch, E.
    Fournier, P.
    Hansen, T. E.
    Kok, A.
    Lerch, M.
    Monakhov, E.
    Morse, J.
    Petasecca, M.
    Requardt, H.
    Rosenfeld, A. B.
    Rohrich, D.
    Sandaker, H.
    Salome, M.
    Stugu, B.
    JOURNAL OF INSTRUMENTATION, 2015, 10
  • [7] Image guided radiation therapy (IGRT) reduces gastrointestinal (GI) sequelae compared with external beam radiation therapy (EBRT) in patients with carcinoma of the prostate (CaP)
    Di Matteo, A.
    Botten, R.
    Butters, J.
    Holloway, R.
    Yeoh, E.
    NEUROGASTROENTEROLOGY AND MOTILITY, 2012, 24 : 186 - 186
  • [8] BROAD-BEAM TRANSMISSION DATA IN LEAD FOR SCATTERED RADIATION PRODUCED AT DIAGNOSTIC ENERGIES
    RAWLINGS, DJ
    FAULKNER, K
    HARRISON, RM
    BRITISH JOURNAL OF RADIOLOGY, 1991, 64 (757): : 69 - 71
  • [9] Normal tissue tolerance to external beam radiation therapy: The stomach
    Oberdiac, P.
    Mineur, L.
    CANCER RADIOTHERAPIE, 2010, 14 (4-5): : 336 - 339
  • [10] Normal tissue tolerance to external beam radiation therapy: Liver
    De Bari, B.
    Pointreau, Y.
    Rio, E.
    Mirabel, X.
    Mornex, F.
    CANCER RADIOTHERAPIE, 2010, 14 (4-5): : 344 - 349