Voltammetric behavior and square-wave voltammetric determination of cefotaxime in urine

被引:31
|
作者
Aleksic, Mara M.
Kapetanovic, Vera
机构
[1] Univ Belgrade, Fac Pharm, Inst Phys Chem, Belgrade 11000, Serbia
[2] Univ Belgrade, Fac Pharm, Inst Analyt Chem, Belgrade 11000, Serbia
来源
JOURNAL OF ELECTROANALYTICAL CHEMISTRY | 2006年 / 593卷 / 1-2期
关键词
cefotaxime; square-wave voltammetry; urine;
D O I
10.1016/j.jelechem.2006.06.011
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The voltammetric behavior of cefotaxime (CFX) is investigated by cyclic and square-wave voltammetry in BR buffers (pH 1.80-12.0). Based on the cathodic reduction peak at approximately -0.5 V in BR buffer (pH 2.8 and 9.25), a robust, highly reliable square-wave voltammetric method (SW) was developed for determination of CFX. The linearity was achieved by SW voltammetry in 7.5 x 10(-9) M (3.52 ng ml(-1)) to 1.0 X 10(-7) M (47 ng ml(-1)) and from 12 x 10(-7) M (56.4 ng ml(-1)) to 1.2 x 10(-6) M (568.8 ng ml(-1)) range at pH 2.8 with detection and quantification limits of 0.813 ng ml(-1) and 2.71 ng ml(-1), and 12.6 ng ml(-1) and 42.2 ng ml(-1), respectively. At pH 9.25 linear range was obtained from 4 x 10(-8) M (18.8 ng ml(-1)) to 1.6 x 10(-7) M (75.2 ng ml(-1)) with detection and quantification limits of 2.947 ng ml(-1) and 9.82 ng ml(-1). The method was applied for CFX determination in spiked humane urine sample. A detection and quantification limits of 7.2 ng ml(-1) and 23.9 ng ml(-1) were achieved for determination of CFX in urine at pH 2.8 and 13.6 ng ml(-1) and 45.1 ng ml(-1) at pH 9.25. The comparative reference method was DPV. The proposed method was checked for determination of CFX in real human urine, and selectivity of the method over the metabolites was found to be quite satisfactory. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:258 / 266
页数:9
相关论文
共 50 条
  • [41] SQUARE-WAVE VOLTAMMETRIC DETERMINATION OF UNBOUND FORMALDEHYDE IN RESIN-TREATED FABRICS
    CARPENTER, BH
    GRAHAM, KM
    NORTH, BF
    YOON, SH
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1985, 189 (APR-): : 3 - CELL
  • [42] A Square-Wave Adsorptive Stripping Voltammetric Method for Determination of Fast Green Dye
    Al-Ghamdi, Ali F.
    JOURNAL OF AOAC INTERNATIONAL, 2009, 92 (06) : 1714 - 1719
  • [43] Voltammetric Behavior of Testosterone on Bismuth Film Electrode: Highly Sensitive Determination in Pharmaceuticals and Human Urine by Square-Wave Adsorptive Stripping Voltammetry
    Levent, Abdulkadir
    Altun, Ahmet
    Tas, Suleyman
    Yardim, Yavuz
    Senturk, Zuhre
    ELECTROANALYSIS, 2015, 27 (05) : 1219 - 1228
  • [44] Electrochemical study and simultaneous square-wave voltammetric determination of tyramine and spermidine in wines
    Nobrega, Rossana O.
    Ramo, Luciano B.
    Silva, Amanda C.
    Araujo, Mario C. U.
    ELECTROANALYSIS, 2024, 36 (11)
  • [45] Square-wave voltammetric determination of paraquat at carbon paste electrode modified with hydroxyapatite
    El Mhanunedi, Moulay Abderrahim
    Bakasse, Mina
    Chtaini, Abdelilah
    ELECTROANALYSIS, 2007, 19 (16) : 1727 - 1733
  • [47] Voltammetric and Square-Wave Anodic Stripping Determination of Amlodipine Besylate on Gold Electrode
    Stoiljkovic, Z. Z.
    Ivic, M. L. Avramov
    Petrovic, S. D.
    Mijin, D. Z.
    Stevanovic, S. I.
    Lacnjevac, U. C.
    Marinkovic, A. D.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2012, 7 (03): : 2288 - 2303
  • [48] Square-wave voltammetric (SWV) determination of Captopril in reconstituted serum and pharmaceutical formulations
    Parham, H
    Zargar, B
    TALANTA, 2005, 65 (03) : 776 - 780
  • [49] ADSORPTIVE STRIPPING SQUARE-WAVE VOLTAMMETRIC BEHAVIOR OF THE ENZYME ADENOSINE-DEAMINASE
    FLORES, JR
    ALVAREZ, JMF
    ELECTROANALYSIS, 1992, 4 (03) : 347 - 354
  • [50] Square-wave adsorptive stripping voltammetric determination of candesartan cilexetil in pharmaceutical formulations
    İncilay Süslü
    Nuran Özaltın
    Sacide Altınöz
    Journal of Applied Electrochemistry, 2009, 39 : 1535 - 1543