Optimization of microwave-assisted solvent extraction of polycyclic aromatic hydrocarbons in marine sediments using a microwave extraction system with high-performance liquid chromatography fluorescence detection and gas chromatography mass spectrometry

被引:103
作者
Chee, KK [1 ]
Wong, MK [1 ]
Lee, HK [1 ]
机构
[1] NATL UNIV SINGAPORE, DEPT CHEM, SINGAPORE 117548, SINGAPORE
关键词
microwave-assisted solvent extraction; microwave extraction system; marine sediments; sediments; mixed-level orthogonal array design; polycyclic aromatic hydrocarbons;
D O I
10.1016/0021-9673(95)00882-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In the present study, a microwave-assisted solvent extraction (MASE) technique using a microwave extraction system (MES) has been developed for the extraction of polycyclic aromatic hydrocarbons (PAHs) from marine sediment. The optimum MASE conditions can be obtained by performing the mixed-level orthogonal array design (OAD) procedure. A comparison between the Soxhlet extraction method and the MASE technique showed that although both techniques gave comparable results on certified reference materials (CRM) HS-4 and HS-6, the MASE technique allows the use of less solvent and is also time-saving and cost-effective without affecting its extraction efficiency. The optimum MASE technique was coupled to two analytical techniques: high-performance liquid chromatography (HPLC) with both ultraviolet (UV) and fluorescence detectors and gas chromatography-mass spectrometry (GC-MS) for the qualitative and quantitative screening of PAHs in CRM and ''real world'' samples. Recoveries of PAHs from two CRMs were all above 73.3%. The concentration of PAHs in marine sediment collected from primary industrial areas was between 0.03 and 0.35 mu g/g on a dry weight basis.
引用
收藏
页码:259 / 271
页数:13
相关论文
共 33 条
[1]   DETERMINATION OF TRACE AMOUNTS OF POLYCYCLIC AROMATIC-HYDROCARBONS IN SOIL [J].
AUER, W ;
MALISSA, H .
ANALYTICA CHIMICA ACTA, 1990, 237 (02) :451-457
[2]   INVESTIGATION INTO THE FACTORS AFFECTING PERFORMANCE IN THE DETERMINATION OF POLYCYCLIC AROMATIC-HYDROCARBONS USING CAPILLARY GAS-CHROMATOGRAPHY MASS-SPECTROMETRY WITH SPLITLESS INJECTION [J].
BRINDLE, ID ;
LI, XF .
JOURNAL OF CHROMATOGRAPHY, 1990, 498 (01) :11-24
[3]   DETERMINATION OF POLYCYCLIC AROMATIC-HYDROCARBONS IN SURFACE-WATER BY COLUMN LIQUID-CHROMATOGRAPHY WITH FLUORESCENCE DETECTION, USING ONLINE MICELLE-MEDIATED SAMPLE PREPARATION [J].
BROUWER, ER ;
HERMANS, ANJ ;
LINGEMAN, H ;
BRINKMAN, UAT .
JOURNAL OF CHROMATOGRAPHY A, 1994, 669 (1-2) :45-57
[4]   ANALYSIS OF POLYCYCLIC AROMATIC-HYDROCARBONS WITH AN ION-TRAP MASS DETECTOR AND COMPARISON WITH OTHER GAS-CHROMATOGRAPHIC AND HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC TECHNIQUES [J].
CASTELLO, G ;
GERBINO, TC .
JOURNAL OF CHROMATOGRAPHY, 1993, 642 (1-2) :351-357
[5]  
DONG MW, 1993, LC GC-MAG SEP SCI, V11, P802
[7]   FAST SEPARATION OF STABILIZERS FROM POLYOLEFINS BY MICROWAVE-HEATING [J].
FREITAG, W ;
JOHN, O .
ANGEWANDTE MAKROMOLEKULARE CHEMIE, 1990, 175 :181-185
[8]   MICROWAVE-EXTRACTION - A NEW METHOD SUPERSEDING TRADITIONAL SOXHLET EXTRACTION [J].
GANZLER, K ;
SALGO, A .
ZEITSCHRIFT FUR LEBENSMITTEL-UNTERSUCHUNG UND-FORSCHUNG, 1987, 184 (04) :274-276
[9]   MICROWAVE EXTRACTION - A NOVEL SAMPLE PREPARATION METHOD FOR CHROMATOGRAPHY [J].
GANZLER, K ;
SALGO, A ;
VALKO, K .
JOURNAL OF CHROMATOGRAPHY, 1986, 371 :299-306
[10]  
GRIMMER G, 1983, ENV CARCINOGENENS PO