Optimization-based vessel segmentation pipeline for robust quantification of capillary networks in skin with optical coherence tomography angiography

被引:13
作者
Casper, Malte [1 ,2 ]
Schulz-Hildebrandt, Hinnerk [2 ,3 ,4 ]
Evers, Michael [1 ]
Birngruber, Reginald [2 ,5 ]
Manstein, Dieter [2 ,5 ]
Huettmann, Gereon [2 ,3 ,4 ]
机构
[1] Harvard Med Sch, Massachusetts Gen Hosp, Dept Dermatol, Cutaneous Biol Res Ctr, Charlestown, MA 02115 USA
[2] Univ Lubeck, Inst Biomed Opt, Lubeck, Germany
[3] LungenClin Grosshansdorf, Airway Res Ctr North, Grosshansdorf, Germany
[4] German Ctr Lung Res, Grosshansdorf, Germany
[5] Med Laser Ctr Lubeck, Lubeck, Germany
关键词
optical coherence tomography; functional imaging; image processing; image analysis; dermatology;
D O I
10.1117/1.JBO.24.4.046005
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Optical coherence tomography angiography (OCTA) provides in-vivo images of microvascular perfusion in high resolution. For its application to basic and clinical research, an automatic and robust quantification of the capillary architecture is mandatory. Only this makes it possible to reliably analyze large amounts of image data, to establish biomarkers, and to monitor disease developments. However, due to its optical properties, OCTA images of skin often suffer from a poor signal-to-noise ratio and contain imaging artifacts. Previous work on automatic vessel segmentation in OCTA mostly focuses on retinal and cerebral vasculature. Its applicability to skin and, furthermore, its robustness against imaging artifacts had not been systematically evaluated. We propose a segmentation method that improves the quality of vascular quantification in OCTA images even if corrupted by imaging artifacts. Both the combination of image processing methods and the choice of their parameters are systematically optimized to match the manual labeling of an expert for OCTA images of skin. The efficacy of this optimization-based vessel segmentation is further demonstrated on sample images as well as by a reduced error of derived quantitative vascular network characteristics. (C) The Authors. Published by SPIE under a Creative Commons Attribution 4.0 Unported License.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Flow measurement without phase information in optical coherence tomography images
    Barton, JK
    Stromski, S
    [J]. OPTICS EXPRESS, 2005, 13 (14) : 5234 - 5239
  • [2] Fast approximate energy minimization via graph cuts
    Boykov, Y
    Veksler, O
    Zabih, R
    [J]. IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 2001, 23 (11) : 1222 - 1239
  • [3] An experimental comparison of min-cut/max-flow algorithms for energy minimization in vision
    Boykov, Y
    Kolmogorov, V
    [J]. IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 2004, 26 (09) : 1124 - 1137
  • [4] A non-local algorithm for image denoising
    Buades, A
    Coll, B
    Morel, JM
    [J]. 2005 IEEE COMPUTER SOCIETY CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION, VOL 2, PROCEEDINGS, 2005, : 60 - 65
  • [5] Measuring tortuosity of the intracerebral vasculature from MRA images
    Bullitt, E
    Gerig, G
    Pizer, SM
    Lin, WL
    Aylward, SR
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2003, 22 (09) : 1163 - 1171
  • [6] Detailed Vascular Anatomy of the Human Retina by Projection-Resolved Optical Coherence Tomography Angiography
    Campbell, J. P.
    Zhang, M.
    Hwang, T. S.
    Bailey, S. T.
    Wilson, D. J.
    Jia, Y.
    Huang, D.
    [J]. SCIENTIFIC REPORTS, 2017, 7
  • [7] Optical coherence tomography in the assessment of acute changes in cutaneous vascular diameter induced by heat stress
    Carter, Howard H.
    Gong, Peijun
    Kirk, Rodney W.
    Es'haghian, Shaghayegh
    Atkinson, Ceri L.
    Sampson, David D.
    Green, Daniel J.
    McLaughlin, Robert A.
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 2016, 121 (04) : 965 - 972
  • [8] Quantitative assessment of the retinal microvasculature using optical coherence tomography angiography
    Chu, Zhongdi
    Lin, Jason
    Gao, Chen
    Xin, Chen
    Zhang, Qinqin
    Chen, Chieh-Li
    Roisman, Luis
    Gregori, Giovanni
    Rosenfeld, Philip J.
    Wang, Ruikang K.
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2016, 21 (06)
  • [9] Image denoising by sparse 3-D transform-domain collaborative filtering
    Dabov, Kostadin
    Foi, Alessandro
    Katkovnik, Vladimir
    Egiazarian, Karen
    [J]. IEEE TRANSACTIONS ON IMAGE PROCESSING, 2007, 16 (08) : 2080 - 2095
  • [10] Optical coherence tomography angiography of normal skin and inflammatory dermatologic conditions
    Deegan, Anthony J.
    Talebi-Liasi, Faezeh
    Song, Shaozhen
    Li, Yuandong
    Xu, Jingjiang
    Men, Shaojie
    Shinohara, Michi M.
    Flowers, Mary E.
    Lee, Stephanie J.
    Wang, Ruikang K.
    [J]. LASERS IN SURGERY AND MEDICINE, 2018, 50 (03) : 183 - 193