Biomechanical Comparison of Fixed- versus Variable-Angle Locking Screws for Distal Humerus Comminuted Fractures

被引:10
作者
Nourbakhsh, Ali [1 ]
Hirschfeld, Adam G. [2 ]
Dhulipala, Sravan [1 ]
Hutton, William [3 ]
Ganey, Timothy [1 ]
Lozada, Luis [1 ]
Schlatterer, Daniel [1 ]
Lourie, Gary Mark [4 ]
机构
[1] WellStar Atlanta Med Ctr, Dept Orthoped, Atlanta, GA USA
[2] MetroHlth Med Ctr, Dept Orthoped, Cleveland, OH USA
[3] Emory Univ, Sch Med, Dept Orthoped, Atlanta, GA USA
[4] Hand & Upper Extrem Ctr Georgia, Dept Orthoped, 980 Johnson Ferry Rd NE,Suite 1020, Atlanta, GA 30342 USA
关键词
Humerus; Fracture fixation; Bone screws; POLYAXIAL LOCKING; PLATE FIXATION; ELBOW JOINT; FORCES;
D O I
10.4055/cios.2019.11.3.302
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: To compare the stability of fixed- versus variable-angle locking constructs for the comminuted distal humerus fracture (AO/OTA 13-A3). Methods: Eight pairs of complete humeri harvested from eight fresh frozen cadavers were used for the study. We fixed the intact humeri using 2.7-mm/3.5-mm locking VA-LCP stainless steel distal humerus posterolateral (nine-hole) and medial (seven-hole) plates. An oscillating saw was used to cut a 1-cm gap above the olecranon fosse. The specimens were loaded in axial mode with the rate of 1 mm per 10 seconds to failure, and stress-strain curves were compared in each pair. The mode of failure was recorded as well as the load needed for 2- and 4-mm displacement at the lateral end of the gap. Results: The stiffness of the constructs, based on the slope of the stress-strain curve, did not show any difference between the fixed- versus variable-angle constructs. Likewise, there was no difference between the force needed for 2- or 4-mm displacement at the lateral gap between the fixed- and variable-angle constructs. The mode of failure was bending of both plates in all specimens and screw pull-out in four specimen pairs in addition to the plate bending. Conclusions: Our results did not show any difference in the biomechanical stability of the fixed- versus variable-angle constructs. There was not any screw breakage or failure of the plate-screw interface.
引用
收藏
页码:302 / 308
页数:7
相关论文
共 21 条
[1]   DERIVATION OF ELBOW JOINT FORCES, AND THEIR RELATION TO PROSTHESIS DESIGN [J].
AMIS, AA ;
DOWSON, D ;
WRIGHT, V ;
MILLER, JH .
JOURNAL OF MEDICAL ENGINEERING & TECHNOLOGY, 1979, 3 (05) :229-234
[2]   MUSCLES ACROSS THE ELBOW JOINT - A BIOMECHANICAL ANALYSIS [J].
AN, KN ;
HUI, FC ;
MORREY, BF ;
LINSCHEID, RL ;
CHAO, EY .
JOURNAL OF BIOMECHANICS, 1981, 14 (10) :659-+
[3]  
Biomet, 2014, POLYAX PER PLAT SYST
[4]  
Cronier P., 2010, Orthopaedics Traumatology: Surgery Research, V96, pS17
[5]   Biomechanical Comparison of Polyaxial and Uniaxial Locking Plate Fixation in a Proximal Tibial Gap Model [J].
Cullen, Aaron B. ;
Curtiss, Shane ;
Lee, Mark A. .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2009, 23 (07) :507-513
[6]  
Dunning CE, 2001, CLIN ORTHOP RELAT R, P118
[7]   Biomechanics of locked plates and screws [J].
Egol, KA ;
Kubiak, EN ;
Fulkerson, E ;
Kummer, FJ ;
Koval, KJ .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2004, 18 (08) :488-493
[8]  
Fornalski Stefan, 2003, Tech Hand Up Extrem Surg, V7, P168, DOI 10.1097/00130911-200312000-00008
[9]   TRANSMISSION OF PRESSURES ACROSS ELBOW JOINT [J].
HALLS, AA ;
TRAVILL, A .
ANATOMICAL RECORD, 1964, 150 (03) :243-&
[10]  
Hart A, 2015, J ORTHOP TRAUMA, V29, pE1, DOI 10.1097/BOT.0000000000000146