Evaluation of an ambulatory system for gait analysis in hip osteoarthritis and after total hip replacement

被引:120
作者
Aminian, K
Trevisan, C
Najafi, B
Dejnabadi, H
Frigo, C
Pavan, E
Telonio, A
Cerati, F
Marinoni, EC
Robert, P
Leyvraz, PF
机构
[1] Swiss Fed Inst Technol, EPFL, Ctr Orthopaed Res, Lab Movement Anal & Measurement, CH-1015 Lausanne, Switzerland
[2] Univ Milan, Osped San Gerardo, Dept Orthopaed Surg, Monza, Italy
[3] IRCCS, Politecn Milan, ONLUS, Ctr Bioingn,Fdn Don Gnocchi, Milan, Italy
[4] Hosp Orthoped Suisse Romande, Lausanne, Switzerland
关键词
gait analysis; ambulatory system; hip osteoarthritis; gyroscope; force plate;
D O I
10.1016/S0966-6362(03)00093-6
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Spatial and temporal parameters of gait have clinical relevance in the assessment of motor pathologies, particularly in orthopaedics. A new gait analysis system is proposed which consists of (a) an ambulatory device (Physilog(R)) including a set of miniature gyroscopes and a portable datalogger, and (b) an algorithm for gait analysis. The aim of this study was the validation of this system, for accuracy and clinical applicability. Eleven patients with coxarthrosis, eight patients with total hip arthroplasty and nine control subjects were studied using this portable system and also a reference motion analyzer and force plate. The small differences in the stance period (19 +/- 31 ms), stride length and velocity (0.4 +/- 9.6 cm and 2.5 +/- 8.3 cm/s, respectively), as well as thigh and shank rotations (2.4 +/- 4.3degrees and 0.3 +/- 3.3degrees, respectively), confirmed good agreement of the proposed system with the reference system. In addition, nearly the same accuracy was obtained for all three groups. Gait analysis based on Physilog(R) was also in agreement with their Harris Hip Scores (HHS): the subjects with lower scores had a greater limp, a slower walking speed and a shorter stride. This ambulatory gait analysis system provides an easy, reproducible and objective method of quantifying changes in gait after joint replacement surgery for coxarthrosis. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:102 / 107
页数:6
相关论文
共 21 条
  • [1] AbuFaraj ZO, 1997, J REHABIL RES DEV, V34, P187
  • [2] Allard P, 1995, 3 DIMENSIONAL ANAL H
  • [3] Spatio-temporal parameters of gait measured by an ambulatory system using miniature gyroscopes
    Aminian, K
    Najafi, B
    Büla, C
    Leyvraz, PF
    Robert, P
    [J]. JOURNAL OF BIOMECHANICS, 2002, 35 (05) : 689 - 699
  • [4] Gait biomechanics and the evolution of total joint replacement
    Andriacchi, TP
    Hurwitz, DE
    [J]. GAIT & POSTURE, 1997, 5 (03) : 256 - 264
  • [5] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [6] DEANDRES E, 1998, P 2 MED C PHYS MED R, P347
  • [7] PATTERN-RECOGNITION IN 3D AUTOMATIC HUMAN MOTION ANALYSIS
    FERRIGNO, G
    BORGHESE, NA
    PEDOTTI, A
    [J]. ISPRS JOURNAL OF PHOTOGRAMMETRY AND REMOTE SENSING, 1990, 45 (04) : 227 - 246
  • [8] ELITE - A DIGITAL DEDICATED HARDWARE SYSTEM FOR MOVEMENT ANALYSIS VIA REAL-TIME TV SIGNAL-PROCESSING
    FERRIGNO, G
    PEDOTTI, A
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1985, 32 (11) : 943 - 950
  • [9] Functionally oriented and clinically feasible quantitative gait analysis method
    Frigo, C
    Rabuffetti, M
    Kerrigan, DC
    Deming, LC
    Pedotti, A
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1998, 36 (02) : 179 - 185
  • [10] Frigo C, 1996, J ORTHOP RHEUMATOL, V9, P82