Enzyme immunometric assay of thyroliberin (TRH)

被引:12
|
作者
Etienne, E
Creminon, C
Grassi, J
Grouselle, D
Roland, J
Pradelles, P
机构
[1] CEA,CE SACLAY,SERV PHARMACOL & IMMUNOL,F-91191 GIF SUR YVETTE,FRANCE
[2] CTR PAUL BROCA,INSERM U159,F-75014 PARIS,FRANCE
[3] UNIV PARIS 06,F-75724 PARIS 15,FRANCE
[4] INST PASTEUR,CNRS URA D1961,DEPT IMMUNOL,UNITE IMMUNOCHIM ANALYT,F-75724 PARIS 15,FRANCE
关键词
TRH; enzyme immunometric assay; monoclonal antibody; acetylcholinesterase; hapten; derivatization;
D O I
10.1016/0022-1759(96)00154-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An enzyme immunometric assay of thyroliberin (TRH) using monoclonal antibodies and a derivatization procedure is described. This assay, named SPIE-IA, involves a four step procedure after chemical derivatization of TRH and biological samples by diazotized APEA. Step 1: derivatized TRH was immunocaptured by a monoclonal anti-TRH antibody coated on a 96-well microtiter plate. Step 2: after washing, derivatized TRH was cross-linked via its amino group to the wells using glutaraldehyde. Step 3: washing and treatment with NaOH. Step 4: measurement of bound TRH using a monoclonal anti-TRH antibody labeled with acetylcholinesterase. The minimal detectable concentration was 0.1 pmol/ml: with a coefficient of variation less than 10% in the 0.156-10 pmol/ml range. This assay is 26-foId more sensitive and more specific than the competitive enzyme immunoassay using the same monoclonal capture antibody, derivatized TRH and TRH-acetylcholinesterase conjugate as tracer. Good correlation was observed between SPIE-IA and a sensitive competitive enzyme immunoassay using polyclonal antibodies.
引用
收藏
页码:79 / 85
页数:7
相关论文
共 50 条
  • [1] RADIOIMMUNOASSAY FOR THYROLIBERIN (TRH) - COMPARISON WITH A TRH RADIORECEPTOR ASSAY
    GROUSELLE, D
    FAIVREBAUMAN, A
    TIXIERVIDAL, A
    NEUROSCIENCE LETTERS, 1978, 7 (01) : 7 - 15
  • [2] ENZYME IMMUNOASSAYS FOR THYROLIBERIN (TRH) AND TRH-ELONGATED PEPTIDES IN MOUSE AND RAT HYPOTHALAMUS
    GROUSELLE, D
    TIXIERVIDAL, A
    PRADELLES, P
    NEUROPEPTIDES, 1990, 17 (03) : 155 - 162
  • [3] DETECTION OF SALMONELLAE IN FOODS WITH AN ENZYME IMMUNOMETRIC ASSAY
    IBRAHIM, GF
    LYONS, MJ
    JOURNAL OF FOOD PROTECTION, 1987, 50 (01) : 59 - 61
  • [4] ENZYME IMMUNOMETRIC ASSAY FOR LEUKOTRIENE C4
    VOLLAND, H
    LENORMAND, BV
    MAMAS, S
    GRASSI, J
    CREMINON, C
    EZAN, E
    PRADELLES, P
    JOURNAL OF IMMUNOLOGICAL METHODS, 1994, 175 (01) : 97 - 105
  • [5] Evaluation of an enzyme immunometric assay to measure serum adiponectin concentrations
    Suominen, P
    CLINICAL CHEMISTRY, 2004, 50 (01) : 219 - 221
  • [6] Validation of a chemiluminescent enzyme immunometric assay for plasma adrenocorticotropic hormone in the dog
    Scott-Moncrieff, JC
    Koshko, MA
    Brown, JA
    Hill, K
    Refsal, KR
    VETERINARY CLINICAL PATHOLOGY, 2003, 32 (04) : 180 - 187
  • [7] AN ENZYME-LABELED IMMUNOMETRIC ASSAY FOR QUANTITATION OF DIGOXIN IN SERUM OR PLASMA
    BRUSTOLIN, D
    SIRTOLI, M
    TARENGHI, G
    THERAPEUTIC DRUG MONITORING, 1992, 14 (01) : 72 - 77
  • [8] ENZYME IMMUNOMETRIC ASSAY FOR ENDOTHELIN USING TANDEM MONOCLONAL-ANTIBODIES
    CREMINON, C
    FROBERT, Y
    HABIB, A
    MACLOUF, J
    PATRONO, C
    PRADELLES, P
    GRASSI, J
    JOURNAL OF IMMUNOLOGICAL METHODS, 1993, 162 (02) : 179 - 192
  • [9] A UNITIZED ENZYME-LABELED IMMUNOMETRIC DIGOXIN ASSAY SUITABLE FOR RAPID TESTING
    SOMMER, RG
    BELCHAK, TL
    BLOCZYNSKI, ML
    BOGUSLAWSKI, SJ
    CLAY, DL
    COREY, PF
    FOLTZ, MM
    FREDRICKSON, RA
    HALMO, BL
    JOHNSON, RD
    MARFURT, KL
    RUNZHEIMER, HV
    MORRIS, DL
    CLINICAL CHEMISTRY, 1990, 36 (02) : 201 - 206
  • [10] Automated quantification of TSH in serum by a chemiluminescent enzyme immunometric assay: Analytical validation
    Alvarez, MLT
    AndradeOlivie, MA
    Garcia, SC
    Perez, DR
    Dominguez, AS
    Sousa, TR
    Novoa, RA
    ANNALES DE BIOLOGIE CLINIQUE, 1996, 54 (8-9) : 325 - 331