Validation of ApneaLink as Screening Device for Cheyne-Stokes Respiration

被引:34
作者
Weinreich, Gerhard [1 ]
Armitstead, Jeff [2 ]
Toepfer, Volker [1 ]
Wang, You-Ming [1 ]
Wang, Yi [1 ]
Teschler, Helmut [1 ,2 ]
机构
[1] Univ Duisburg Essen, Dept Resp Med, Fac Med, Essen, Germany
[2] Univ New S Wales, Grad Sch Biomed Sci, Sydney, NSW, Australia
基金
澳大利亚研究理事会;
关键词
ApneaLink; Cheyne-Stokes respiration; obstructive sleep apnea; pattern recognition; sleep disordered breathing; screening; OBSTRUCTIVE SLEEP-APNEA; HEART-FAILURE; MORTALITY;
D O I
10.1093/sleep/32.4.553
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Objectives: Polysomnography (PSG) is the gold standard in diagnosing sleep disordered breathing (SDB). Diagnostic analysis of SDB is time-consuming and labor-intensive and entails long waiting lists for patients. The aim of this study was to assess the validity of a flow-based screening classifier as an automated diagnostic test for Cheyne-Stokes respiration (CSR). Setting: Sleep laboratory Participants: 70 study subjects (28 with obstructive sleep apnea [OSA], 20 with CSR, 11 with CSR+OSA and 11 without SDB) Measurements: The nasal cannula flow signal was analyzed by ApneaLink (ResMed, Sydney, Australia), based on a classifier algorithm using pattern recognition. In a simultaneous PSG, results were compared with manual scoring of respiratory events by certified sleep experts. Results: For detecting CSR we obtained a sensitivity of 87.1% (95% confidence interval 75.3% to 98.9%), a specificity of 94.9% (95% confidence interval 87.9% to 100%), a positive likelihood ratio of 17.0, and a negative likelihood ratio of 0.14. The area under the curve (AUC) of the according receiver operating characteristic (ROC) curve was 93.4%. This resulted in an accuracy of 91.4% for identifying CSR. Conclusion: In this study we demonstrated that the screening classifier was able to detect CSR with high diagnostic accuracy. Hence, ApneaLink equipped with CSR classifier is an appropriate screening tool which may help to prioritize patients with CSR for PSG.
引用
收藏
页码:553 / 557
页数:5
相关论文
共 24 条
[1]  
[Anonymous], 1992, SLEEP, V15, P174
[2]  
[Anonymous], 2007, The AASM manual for the scoring of sleep and associated events: rules, terminology and technical specifications, V1A
[3]  
Bishop Christopher M, 1995, Neural networks for pattern recognition
[4]   Causes of Cheyne-Stokes respiration [J].
Cherniack, NS ;
Longobardo, G ;
Evangelista, CJ .
NEUROCRITICAL CARE, 2005, 3 (03) :271-279
[5]  
Duda R. O., 2000, Pattern classification
[6]  
El-Solh A. A., 2003, Journal of Medical Engineering & Technology, V27, P54, DOI 10.1080/0309190021000043693
[7]  
Erman MK, 2007, J CLIN SLEEP MED, V3, P387
[8]   Night-to-night variation of the oxygen desaturation index in sleep apnoea syndrome [J].
Fietze, I ;
Dingli, K ;
Diefenbach, K ;
Douglas, NJ ;
Glos, M ;
Tallafuss, M ;
Terhalle, W ;
Witt, C .
EUROPEAN RESPIRATORY JOURNAL, 2004, 24 (06) :987-993
[9]   Access to diagnosis and treatment of patients with suspected sleep apnea [J].
Flemons, WW ;
Douglas, NJ ;
Kuna, ST ;
Rodenstein, DO ;
Wheatley, J .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2004, 169 (06) :668-672
[10]   Measuring agreement between diagnostic devices [J].
Flemons, WW ;
Littner, MR .
CHEST, 2003, 124 (04) :1535-1542