Power Quality Analysis by H-Bridge DSTATCOM Control by Icosθ and ESRF SOGI-FLL Methods for Different Industrial Loads

被引:0
|
作者
Islavatu, Srikanth [1 ]
Kumar, Pradeep [1 ]
Kumar, Amit [1 ]
Salkuti, Surender Reddy [2 ]
机构
[1] Natl Inst Technol Sikkim, Dept Elect & Elect Engn, Sikkim 737139, India
[2] Woosong Univ, Dept Railrd & Elect Engn, Jayang Dong, Daejeon 34606, South Korea
来源
SMART CITIES | 2022年 / 5卷 / 04期
关键词
Icos theta; enhanced SRF SOGI-FLL; harmonic; voltage source- and current source-based non-linear loads; induction heating-based loads; electric arc furnace; MITIGATION;
D O I
10.3390/smartcities5040081
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This work develops the analysis of power quality by the H-bridge Static Distribution Compensator (DSTATCOM) as well as its control techniques in different industry-based loading conditions. The function of DSTATCOM is to diminish power quality problems arising due to commercial as well as industrial loads. For reference current extraction, the novel Icos theta and proposed enhanced SRF SOGI-FLL (synchronous reference frame second-order generalized integrator frequency-locked loop) controller have been adopted in the H-bridge DSTATCOM. The Icos theta controller's performance is dependent on the in-phase and quadrature-phase angle, which changes accordingly as load changes, whereas the proposed enhanced SRF SOGI-FLL controller works in synchronization with the grid with an inverter. The two control techniques were compared in terms of balancing, power factor improvement, DC-link voltage control, and harmonic minimization. The harmonics minimization of the proposed controller has been validated by IEEE 519 standards. The extracted reference currents are fed to the hysteresis current controller for the generation of pulses toward the inverter switches of DSTATCOM. The DSTATCOM system along with control algorithms have been tested on various loading conditions, i.e., voltage source- and current source-based non-linear loads, induction heating-based loads, and electric arc furnace. The complete DSTATCOM systems were implemented and executed in the MATLAB/Simulink platform and then power quality improvement features were investigated.
引用
收藏
页码:1590 / 1610
页数:21
相关论文
共 23 条
  • [1] Comparative power quality analysis of conventional and proposed enhanced SRF SOGI-FLL control based DSTATCOM
    Kumar, Amit
    Kumar, Pradeep
    JOURNAL OF ENGINEERING RESEARCH, 2022, 10 (3A): : 145 - 174
  • [2] Efficient controller of DSTATCOM based on combination of Adaline and SOGI-FLL for power quality improvement
    Kumar, Amit
    Kumar, Pradeep
    INTERNATIONAL JOURNAL OF SYSTEM ASSURANCE ENGINEERING AND MANAGEMENT, 2023, 14 (04) : 1543 - 1566
  • [3] Efficient controller of DSTATCOM based on combination of Adaline and SOGI-FLL for power quality improvement
    Amit Kumar
    Pradeep Kumar
    International Journal of System Assurance Engineering and Management, 2023, 14 : 1543 - 1566
  • [4] Power balancing control strategies for the cascaded H-bridge multilevel DSTATCOM
    Han, Yang
    Xu, Lin
    Khan, Muhammad Mansoor
    Chen, Chen
    PRZEGLAD ELEKTROTECHNICZNY, 2011, 87 (02): : 212 - 219
  • [5] Control of cascaded H-Bridge converter based DSTATCOM for high power applications
    Anuradha, K.
    Muni, B. P.
    Kumar, A. D. Raj
    2006 IEEE INTERNATIONAL CONFERENCE ON POWER ELECTRONIC, DRIVES AND ENERGY SYSTEMS, VOLS 1 AND 2, 2006, : 718 - +
  • [6] Isolated H-Bridge VSC Based 3-Phase 4-Wire DSTATCOM for Power Quality Improvement
    Singh, Bhim
    Jayaprakash, P.
    Kothari, D. P.
    2008 IEEE INTERNATIONAL CONFERENCE ON SUSTAINABLE ENERGY TECHNOLOGIES (ICSET), VOLS 1 AND 2, 2008, : 366 - +
  • [7] Novel Hybrid Cascade H-bridge Active Power Filter with Star Configuration for Nonlinear Powerful Industrial Loads
    Abdulveleev, I. R.
    Khramshin, T. R.
    Kornilov, G. P.
    2018 INTERNATIONAL CONFERENCE ON INDUSTRIAL ENGINEERING, APPLICATIONS AND MANUFACTURING (ICIEAM), 2018,
  • [8] Three-Phase Four-Wire DSTATCOM with H-Bridge VSC and Star/Delta Transformer for Power Quality Improvement
    Singh, Bhim
    Jayaprakash, P.
    Kothari, D. P.
    PROCEEDINGS OF THE INDICON 2008 IEEEE CONFERENCE & EXHIBITION ON CONTROL, COMMUNICATIONS AND AUTOMATION, VOL II, 2008, : 412 - +
  • [9] A DC Voltage Control Method of Cascaded H-bridge Inverter for Power Quality Conditioner
    Qiu, Yanhui
    He, Yingjie
    Liu, Jinjun
    Zhuo, Fang
    IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS (ISIE 2010), 2010, : 2879 - 2884
  • [10] Topology Analysis of H-bridge Snubber for EAST Fast Control Power Supply
    Xu, Qianglin
    Zhu, Lili
    Gao, Ge
    Sheng, Zhicai
    Yang, Lei
    Yang, Yalong
    FUSION ENGINEERING AND DESIGN, 2021, 171