共 50 条
Comparative effectiveness of devices for transcatheter closure of atrial septal defects: Systematic review and network meta-analysis
被引:4
作者:
Vishwanath, Varnita
[1
]
Akseer, Selai
[2
,3
]
Frankfurter, Claudia
[1
]
Reza, Seleman
[3
]
Farrell, Ashley
[4
]
Horlick, Eric
[1
]
Abrahamyan, Lusine
[2
,3
]
机构:
[1] Univ Hlth Network, Toronto Congenital Cardiac Ctr Adults, Peter Munk Cardiac Ctr PMCC, Toronto, ON M5G 2N2, Canada
[2] Univ Hlth Network, Toronto Gen Hosp, Res Inst, 10th Floor Eaton North,Room 237,200 Elizabeth St, Toronto, ON M5G 2C4, Canada
[3] Univ Toronto, Inst Hlth Policy Management & Evaluat IHPME, Toronto, ON M5T 3M6, Canada
[4] Univ Hlth Network, Lib & Informat Serv, Toronto, ON M5G 2C4, Canada
关键词:
Atrial septal defect;
Transcatheter devices;
Safety outcomes;
Systematic review;
PERCUTANEOUS CLOSURE;
FOLLOW-UP;
CATHETER CLOSURE;
ASD OCCLUDER;
AMPLATZER(R);
MULTICENTER;
IMPACT;
ADULTS;
OCCLUSION;
OUTCOMES;
D O I:
10.1016/j.acvd.2022.09.002
中图分类号:
R5 [内科学];
学科分类号:
1002 ;
100201 ;
摘要:
Atrial septal defect is a common congenital heart disease, producing a left-to-right shunt in the atrial septum; the current preferred treatment is transcatheter device closure. The aim is to conduct a sys-tematic review to synthesize information on the comparative effectiveness and safety of atrial septal defect closure devices. The methods used: a comprehensive search of Ovid MEDLINE (R), Embase, and Cochrane Central databases was conducted. Studies comparing procedural and follow-up outcomes of atrial septal defect devices were included. Network meta-analyses were conducted to generate direct and indirect evidence for comparative effectiveness and safety outcomes between devices. The results are as follows: Twelve studies met our inclusion criteria and were compared in network meta-analyses. The meta-analyses evaluated contemporary devices: the AMPLATZER Septal Occluder; the GORE CAR-DIOFORM Septal Occluder; the Figulla Flexible II Occluder; the CeraFlex Septal Occluder; and the HELEX Septal Occluder. These studies represented 3998 patients. The primary safety and efficacy outcomes were device embolization and follow-up residual shunt, respectively. Secondary clinical outcomes included procedural success and major and minor complications. No differences were found between devices in terms of device embolization and secondary clinical outcomes. Follow-up residual shunt was higher with the HELEX Septal Occluder compared with the AMPLATZER Septal Occluder (odds ratio 2.92, 95% confi-dence interval 1.12-7.61). To conclude: although most outcomes were similar between devices, evidence was largely based on observational low-quality studies. There were inconsistencies in outcome reporting and definitions; this merits future studies, with head-to-head device comparisons and standardization of outcomes. (c) 2022 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:664 / 674
页数:11
相关论文
共 50 条