Calibration of Miniature Medical Ultrasonic Hydrophones for Frequencies in the Range 100 to 500 kHz Using an Ultrasonically Absorbing Waveguide

被引:0
|
作者
Rajagopal, Srinath [1 ]
Zeqiri, Bajram [1 ]
Gelat, Pierre N. [1 ]
机构
[1] Natl Phys Lab, Acoust & Ionising Radiat Div, Teddington TW11 0LW, Middx, England
关键词
TIME-DELAY SPECTROMETRY; 60; MHZ; MODEL;
D O I
10.1109/TUFFC.2014.2969
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Enhancements to the existing primary standard optical interferometer and narrowband tone-burst comparison calibration methods for miniature medical ultrasonic hydrophones of the membrane type over the frequency range 100 to 500 kHz are described. Improvements were realized through application of an ultrasonically absorbing waveguide made of a low-frequency-absorbing tile used in sonar applications which narrows the spatial extent of the broad acoustic field. The waveguide was employed in conjunction with a sonar multilayered polyvinylidene difluoride (PVDF) hydrophone used as a transmitting transducer covering a frequency range of 100 kHz to 1 MHz. The acoustic field emanating from the ultrasonically absorbing waveguide reduced the significance of diffracted acoustic waves from the membrane hydrophone ring and the consequent interference of this wave with the direct acoustic wave received by the active element of the hydrophone during calibration. Four membrane hydrophone make/models with ring sizes (defined as the inner diameter of the annular mounting ring of the hydrophone) in the range 50 to 100 mm were employed along with a needle hydrophone. A reference membrane hydrophone, calibrated using the NPL primary standard optical interferometer in combination with the ultrasonically absorbing waveguide, was subsequently used to calibrate the other four hydrophones by comparison, again using the ultrasonically absorbing waveguide. In comparison to existing methods, the use of the ultrasonically absorbing waveguide enabled the low-frequency calibration limit of a membrane hydrophone with a ring diameter of 50 mm to be reduced from 400 kHz to 200 kHz.
引用
收藏
页码:765 / 778
页数:14
相关论文
共 7 条
  • [1] Primary calibration of hydrophones in the frequency range 10 to 500 kHz using a heterodyne interferometer
    Wang, Min
    Yang, Ping
    He, Longbiao
    Feng, Xiujuan
    Xing, Guangzhen
    Shengxue Xuebao/Acta Acustica, 2021, 46 (04): : 614 - 622
  • [2] ANGULAR RESPONSE OF MINIATURE ULTRASONIC HYDROPHONES AT MEDICAL DIAGNOSTIC FREQUENCIES
    SHOMBERT, DG
    SMITH, SW
    HARRIS, GR
    ULTRASONIC IMAGING, 1981, 3 (02) : 194 - 195
  • [3] CALIBRATION AND PERFORMANCE EVALUATION OF MINIATURE ULTRASONIC HYDROPHONES USING TIME-DELAY SPECTROMETRY
    LEWIN, PA
    IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1982, 29 (03): : 190 - 190
  • [4] AIR SOUND TRANSDUCER FOR FREQUENCIES IN RANGE 50 KHZ TO 100 KHZ USING SELL PRINCIPLE
    ANKE, DV
    ACUSTICA, 1974, 30 (01): : 30 - 39
  • [5] Technique for the calibration of hydrophones in the frequency range 10 to 600 kHz using a heterodyne interferometer and an acoustically compliant membrane
    Theobald, PD
    Robinson, SP
    Thompson, AD
    Preston, RC
    Lepper, PA
    Wang, YB
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2005, 118 (05): : 3110 - 3116
  • [6] Visualisation and electrochemical determination of the actives zones in an ultrasonic reactor using 20 and 500 kHz frequencies
    Viennet, R
    Ligier, V
    Hihn, JY
    Bereziat, D
    Nika, P
    Doche, ML
    ULTRASONICS SONOCHEMISTRY, 2004, 11 (3-4) : 125 - 129
  • [7] CCAUV.W-K2 final report - key comparison CCAUV.W-K2: calibration of hydrophones in the frequency range from 250 Hz to 500 kHz
    Robinson S.P.
    Harris P.M.
    Ford B.
    Ablitt J.
    Yi C.
    Biber A.
    Corakci A.C.
    Costa-Felix R.
    Crocker S.
    Isaev A.
    Tyalimpi V.
    Latha G.
    Metrologia, 2023, 59 (1A)