Out-of-plane strengthening of unreinforced masonry walls using near surface mounted fibre reinforced polymer strips

被引:70
作者
Dizhur, Dmytro [1 ]
Griffith, Michael [2 ]
Ingham, Jason [1 ]
机构
[1] Univ Auckland, Dept Environm & Civil Engn, Auckland 1, New Zealand
[2] Univ Adelaide, Sch Civil Environm & Min Engn, Adelaide, SA, Australia
关键词
Unreinforced masonry; Clay brick masonry; NSM CFRP; Airbag loading; Retrofit; CLAY BRICK MASONRY; NSM CFRP STRIPS; FRP STRIPS; BEHAVIOR; BUILDINGS; CHRISTCHURCH; PERFORMANCE; EARTHQUAKE; RESISTANCE; JOINTS;
D O I
10.1016/j.engstruct.2013.10.026
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The development of cost effective and minimally-invasive seismic retrofit techniques is required for clay brick unreinforced masonry (URM) buildings because of their poor performance in past earthquakes. A laboratory-based experimental program was implemented to address this need, having well-defined but artificial boundary conditions, and utilising constituent construction materials that replicated the characteristics of masonry found in historic URM buildings. The purpose of this experimental program was to investigate the performance of near-surface mounted (NSM) carbon fibre reinforced polymer (CFRP) strips as a seismic retrofit solution for improving the out-of-plane performance of walls in URM buildings. In the experimental testing program nine masonry beams and five full-scale masonry walls were tested. Details of the design methodology for flexural retrofit of URM walls using the NSM CFRP retrofit technique and laboratory test results are reported. The results of the experimental tests confirmed that the NSM CFRP retrofit technique is a minimally-invasive option for seismic strengthening of URM walls to resist out-of-plane earthquake induced lateral forces. Two recent case-study projects that implemented the NSM CFRP technique are also briefly presented. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:330 / 343
页数:14
相关论文
共 48 条
[1]   Strengthening of unreinforced masonry walls using FRPs [J].
Albert, ML ;
Elwi, AE ;
Cheng, JJR .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2001, 5 (02) :76-84
[2]  
American Society for Testing and Materials (ASTM) International, 2010, ASTM D695-10
[3]   Out-of-plane behavior of unreinforced masonry brick walls strengthened with CFRP strips [J].
Anil, Ozgur ;
Tatayoglu, Muhammed ;
Demirhan, Murat .
CONSTRUCTION AND BUILDING MATERIALS, 2012, 35 :614-624
[4]  
[Anonymous], C131403B ASTM INT
[5]  
[Anonymous], 2005, EN1961 EUR COMM STAN
[6]  
[Anonymous], C109C109M08 ASTM INT
[7]  
[Anonymous], 2021, ASTM C67/C67M-21, DOI [10.1520/C0067_C0067M-21, DOI 10.1520/C0067_C0067M-21]
[8]  
[Anonymous], 1981, DIN53455
[9]   In situ cyclic tests on existing stone masonry walls and strengthening solutions [J].
Costa, Alexandre A. ;
Arede, Antonio ;
Costa, Anibal ;
Oliveira, Carlos Sousa .
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2011, 40 (04) :449-471
[10]   Airbag testing of multi-leaf unreinforced masonry walls subjected to one-way bending [J].
Derakhshan, Hossein ;
Griffith, Michael C. ;
Ingham, Jason M. .
ENGINEERING STRUCTURES, 2013, 57 :512-522