CT Scan Parameters and Radiation Dose: Practical Advice for Radiologists

被引:90
作者
Raman, Siva P. [1 ]
Mahesh, Mahadevappa [1 ]
Blasko, Robert V. [1 ]
Fishman, Elliot K. [1 ]
机构
[1] Johns Hopkins Univ, Dept Radiol, Baltimore, MD 21287 USA
关键词
Radiation dose; automated tube current modulation; low kVp; pitch; iterative reconstruction; MULTIDETECTOR ROW CT; STATISTICAL ITERATIVE RECONSTRUCTION; AUTOMATIC EXPOSURE CONTROL; IMAGE QUALITY; COMPUTED-TOMOGRAPHY; BEAM COLLIMATION; ABDOMINAL CT; REDUCTION; NOISE; PITCH;
D O I
10.1016/j.jacr.2013.05.032
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Although there has been increasing recognition of the importance of reducing radiation dose when performing multidetector CT examinations, the increasing complexity of CT scanner technology, as well as confusion about the importance of many different CT scan parameters, has served as an impediment to radiologists seeking to create lower dose protocols. The authors seek to guide radiologists through the manipulation of 8 fundamental CT scan parameters that can be altered or optimized to reduce patient radiation dose, including detector configuration, tube current, tube potential, reconstruction algorithm, patient positioning, scan range, reconstructed slice thickness, and pitch. Although there is always an inherent trade-off between image quality or noise and patient radiation dose, in many cases, a reasoned manipulation of these 8 parameters can allow the safer imaging of patients (with lower dose) while preserving diagnostic image quality.
引用
收藏
页码:840 / 846
页数:7
相关论文
共 36 条
[1]   Radiation Dose and Image Quality at High-Pitch CT Angiography of the Aorta: Intraindividual and Interindividual Comparisons With Conventional CT Angiography [J].
Apfaltrer, Paul ;
Hanna, E. Lexworth ;
Schoepf, U. Joseph ;
Spears, J. Reid ;
Schoenberg, Stefan O. ;
Fink, Christian ;
Vliegenthart, Rozemarijn .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (06) :1402-1409
[2]   Current concepts - Computed tomography - An increasing source of radiation exposure [J].
Brenner, David J. ;
Hall, Eric J. .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 357 (22) :2277-2284
[3]   Dose Reduction in Helical CT: Dynamically Adjustable z-Axis X-Ray Beam Collimation [J].
Christner, Jodie A. ;
Zavaletta, Vanessa A. ;
Eusemann, Christian D. ;
Walz-Flannigan, Alisa I. ;
McCollough, Cynthia H. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (01) :W49-W55
[4]   Impact of iterative reconstruction on image quality and radiation dose in multidetector CT of large body size adults [J].
Desai, Gaurav S. ;
Uppot, Raul N. ;
Yu, Elaine W. ;
Kambadakone, Avinash R. ;
Sahani, Dushyant V. .
EUROPEAN RADIOLOGY, 2012, 22 (08) :1631-1640
[5]   Optimization of Kilovoltage and Tube Current-Exposure Time Product Based on Abdominal Circumference: An Oval Phantom Study for Pediatric Abdominal CT [J].
Dong, Frank ;
Davros, William ;
Pozzuto, Jessica ;
Reid, Janet .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (03) :670-676
[6]   Radiation dose reduction by using 100-kV tube voltage in cardiac 64-slice computed tomography: A comparative study [J].
Feuchtner, Gudrun M. ;
Jodocy, Daniel ;
Klauser, Andrea ;
Haberfellner, Bernhard ;
Aglan, Iman ;
Spoeck, Alexander ;
Hiehs, Stefan ;
Soegner, Peter ;
Jaschke, Werner .
EUROPEAN JOURNAL OF RADIOLOGY, 2010, 75 (01) :E51-E56
[7]   Computed tomography-old ideas and new technology [J].
Fleischmann, Dominik ;
Boas, F. Edward .
EUROPEAN RADIOLOGY, 2011, 21 (03) :510-517
[8]   Automated tube potential selection for standard chest and abdominal CT in follow-up patients with testicular cancer: comparison with fixed tube potential [J].
Gnannt, Ralph ;
Winklehner, Anna ;
Eberli, Daniel ;
Knuth, Alexander ;
Frauenfelder, Thomas ;
Alkadhi, Hatem .
EUROPEAN RADIOLOGY, 2012, 22 (09) :1937-1945
[9]   Principles of CT: Multislice CT [J].
Goldman, Lee W. .
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY, 2008, 36 (02) :57-68
[10]   Efficient Use of Automatic Exposure Control Systems in Computed Tomography Requires Correct Patient Positioning [J].
Gudjonsdottir, J. ;
Svensson, J. R. ;
Campling, S. ;
Brennan, P. C. ;
Jonsdottir, B. .
ACTA RADIOLOGICA, 2009, 50 (09) :1035-1041