Evaluation of the RealTime HIV-1, Xpert HIV-1, and Aptima HIV-1 Quant Dx Assays in Comparison to the NucliSens EasyQ HIV-1 v2.0 Assay for Quantification of HIV-1 Viral Load

被引:46
|
作者
Mor, Orna [1 ]
Gozlan, Yael [1 ]
Wax, Marina [1 ]
Mileguir, Fernando [1 ]
Rakovsky, Avia [1 ]
Noy, Bina [2 ]
Mendelson, Ella [1 ,3 ]
Levy, Itzchak [4 ]
机构
[1] Chaim Sheba Med Ctr, Minist Hlth, Cent Virol Lab, Natl HIV Reference Lab, Ramat Gan, Israel
[2] Ilex Med, Petah Tiqwa, Israel
[3] Tel Aviv Univ, Sch Publ Hlth, IL-69978 Tel Aviv, Israel
[4] Chaim Sheba Med Ctr, Infect Dis Unit, Ramat Gan, Israel
关键词
TAQMAN HIV-1; VERSION; 2.0; SUBTYPE DISTRIBUTION; PERFORMANCE; RESISTANCE; SAMPLES; CHINA;
D O I
10.1128/JCM.01806-15
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
HIV-1 RNA monitoring, both before and during antiretroviral therapy, is an integral part of HIV management worldwide. Measurements of HIV-1 viral loads are expected to assess the copy numbers of all common HIV-1 subtypes accurately and to be equally sensitive at different viral loads. In this study, we compared for the first time the performance of the NucliSens v2.0, RealTime HIV-1, Aptima HIV-1 Quant Dx, and Xpert HIV-1 viral load assays. Plasma samples (n = 404) were selected on the basis of their NucliSens v2.0 viral load results and HIV-1 subtypes. Concordance, linear regression, and Bland-Altman plots were assessed, and mixed-model analysis was utilized to compare the analytical performance of the assays for different HIV-1 subtypes and for low and high HIV-1 copy numbers. Overall, high concordance (>83.89%), high correlation values (Pearson r values of >0.89), and good agreement were observed among all assays, although the Xpert and Aptima assays, which provided the most similar outputs (estimated mean viral loads of 2.67 log copies/ml [95% confidence interval [CI], 2.50 to 2.84 log copies/ml] and 2.68 log copies/ml [95% CI, 2.49 to 2.86 log copies/ml], respectively), correlated best with the RealTime assay (89.8% concordance, with Pearson r values of 0.97 to 0.98). These three assays exhibited greater precision than the NucliSens v2.0 assay. All assays were equally sensitive for subtype B and AG/G samples and for samples with viral loads of 1.60 to 3.00 log copies/ml. The NucliSens v2.0 assay underestimated A1 samples and those with viral loads of >3.00 log copies/ml. The RealTime assay tended to underquantify subtype C (compared to the Xpert and Aptima assays) and subtype A1 samples. The Xpert and Aptima assays were equally efficient for detection of all subtypes and viral loads, which renders these new assays most suitable for clinical HIV laboratories.
引用
收藏
页码:3458 / 3465
页数:8
相关论文
共 50 条
  • [41] Comparison of the Roche COBAS AmpliPrep/COBAS TaqMan HIV-1 test v1.0 with v2.0 in HIV-1 viral load quantification
    Tung, Yi-Ching
    Ke, Liang-Yin
    Lu, Po-Liang
    Lin, Kuei-Hsiang
    Lee, Su-Chen
    Lin, Yi-Ying
    Chou, Li-Chiu
    Tsai, Wen-Chan
    KAOHSIUNG JOURNAL OF MEDICAL SCIENCES, 2015, 31 (04): : 188 - 193
  • [42] Performance evaluation of the Aptima® HIV-1 Quant Dx and Aptima® HBV Quant assays on the fully automated Panther in comparison to COBAS® AmpliPrep/COBAS® TaqMan® HIV-1 and HBV tests
    Ebel, A.
    Bali, C.
    Guis, L.
    Merlin, S.
    JOURNAL OF CLINICAL VIROLOGY, 2016, 82 : S35 - S36
  • [43] Comparative performance of the new Aptima HIV-1 Quant Dx assay with three commercial PCR-based HIV-1 RNA quantitation assays
    Hopkins, Mark
    Hau, Sarah
    Tiernan, Caroline
    Papadimitropoulos, Athanasios
    Chawla, Anu
    Beloukas, Apostolos
    Geretti, Anna Maria
    JOURNAL OF CLINICAL VIROLOGY, 2015, 69 : 56 - 62
  • [44] Evaluation of Xpert HIV-1 Qual assay for resolution of HIV-1 infection in samples with negative or indeterminate Geenius HIV-1/2 results
    Michaeli, Michal
    Wax, Marina
    Gozlan, Yael
    Rakovsky, Aviya
    Mendelson, Ella
    Mor, Orna
    JOURNAL OF CLINICAL VIROLOGY, 2016, 76 : 1 - 3
  • [45] Performance evaluation of the COBAS/TaqMan HIV-1 v2.0 in HIV-1 positive patients with low viral load: A comparative study
    Paba, Pierpaolo
    Fabeni, Lavinia
    Ciccozzi, Massimo
    Perno, Carlo Federico
    Ciotti, Marco
    JOURNAL OF VIROLOGICAL METHODS, 2011, 173 (02) : 399 - 402
  • [46] Comparison between the automated Roche Cobas AmpliPrep/Cobas TaqMan HIV-1 test version 2.0 assay and its version 1 and Nuclisens HIV-1 EasyQ version 2.0 assays when measuring diverse HIV-1 genotypes in China
    Xu, Sihong
    Song, Aijing
    Nie, Jianhui
    Li, Xiuhua
    Meng, Shufang
    Zhang, Chuntao
    Wang, Youchun
    JOURNAL OF CLINICAL VIROLOGY, 2012, 53 (01) : 33 - 37
  • [47] High correlation between the Roche COBAS® AmpliPrep/COBAS® TaqMan® HIV-1, v2.0 and the Abbott m2000 RealTime HIV-1 assays for quantification of viral load in HIV-1 B and non-B subtypes
    Karasi, J. C.
    Dziezuk, F.
    Quennery, L.
    Foerster, S.
    Reischl, U.
    Colucci, G.
    Schoener, D.
    Seguin-Devaux, C.
    Schmit, J. C.
    JOURNAL OF CLINICAL VIROLOGY, 2011, 52 (03) : 181 - 186
  • [48] Diagnostic Accuracy of the Rapid Xpert HIV-1 Viral Load XC, Xpert HIV-1 Viral Load, & m-PIMA HIV-1/2 Viral Load in South African Clinics
    Dorward, Jienchi
    Naidoo, Jessica
    Moodley, Pravikrishnen
    Sookrajh, Yukteshwar
    Samsunder, Natasha
    Sayed, Fathima
    Naicker, Nivashnee
    Fanshawe, Thomas
    Drain, Paul K.
    Lessells, Richard J.
    Hayward, Gail
    Butler, Christopher C.
    Garrett, Nigel
    JAIDS-JOURNAL OF ACQUIRED IMMUNE DEFICIENCY SYNDROMES, 2022, 91 (02) : 189 - 196
  • [49] Comparison of Abbott RealTime HIV-1 and Roche COBAS® AmpliPrep/COBAS® TaqMan® HIV-1 Assays
    Abravaya, K.
    Hackett, J.
    Swanson, P.
    Huang, S.
    Tang, N.
    Robinson, J.
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2008, 10 (06): : 587 - 587
  • [50] Falsely elevated HIV-1 viral load results observed with Roche TaqMan HIV-1 v2.0 for samples stored frozen in Vacutainer plasma preparation tubes not observed with Abbott RealTime HIV-1
    Cloherty, G.
    Swanson, P.
    Lucic, D.
    Dieckhaus, K.
    Anthony, P.
    Cataline, P.
    Herman, C.
    Hackett, J., Jr.
    Skolnik, P.
    Chirch, L.
    ANTIVIRAL THERAPY, 2013, 18 : A95 - A95