Evaluation of the RealTime HIV-1, Xpert HIV-1, and Aptima HIV-1 Quant Dx Assays in Comparison to the NucliSens EasyQ HIV-1 v2.0 Assay for Quantification of HIV-1 Viral Load

被引:46
|
作者
Mor, Orna [1 ]
Gozlan, Yael [1 ]
Wax, Marina [1 ]
Mileguir, Fernando [1 ]
Rakovsky, Avia [1 ]
Noy, Bina [2 ]
Mendelson, Ella [1 ,3 ]
Levy, Itzchak [4 ]
机构
[1] Chaim Sheba Med Ctr, Minist Hlth, Cent Virol Lab, Natl HIV Reference Lab, Ramat Gan, Israel
[2] Ilex Med, Petah Tiqwa, Israel
[3] Tel Aviv Univ, Sch Publ Hlth, IL-69978 Tel Aviv, Israel
[4] Chaim Sheba Med Ctr, Infect Dis Unit, Ramat Gan, Israel
关键词
TAQMAN HIV-1; VERSION; 2.0; SUBTYPE DISTRIBUTION; PERFORMANCE; RESISTANCE; SAMPLES; CHINA;
D O I
10.1128/JCM.01806-15
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
HIV-1 RNA monitoring, both before and during antiretroviral therapy, is an integral part of HIV management worldwide. Measurements of HIV-1 viral loads are expected to assess the copy numbers of all common HIV-1 subtypes accurately and to be equally sensitive at different viral loads. In this study, we compared for the first time the performance of the NucliSens v2.0, RealTime HIV-1, Aptima HIV-1 Quant Dx, and Xpert HIV-1 viral load assays. Plasma samples (n = 404) were selected on the basis of their NucliSens v2.0 viral load results and HIV-1 subtypes. Concordance, linear regression, and Bland-Altman plots were assessed, and mixed-model analysis was utilized to compare the analytical performance of the assays for different HIV-1 subtypes and for low and high HIV-1 copy numbers. Overall, high concordance (>83.89%), high correlation values (Pearson r values of >0.89), and good agreement were observed among all assays, although the Xpert and Aptima assays, which provided the most similar outputs (estimated mean viral loads of 2.67 log copies/ml [95% confidence interval [CI], 2.50 to 2.84 log copies/ml] and 2.68 log copies/ml [95% CI, 2.49 to 2.86 log copies/ml], respectively), correlated best with the RealTime assay (89.8% concordance, with Pearson r values of 0.97 to 0.98). These three assays exhibited greater precision than the NucliSens v2.0 assay. All assays were equally sensitive for subtype B and AG/G samples and for samples with viral loads of 1.60 to 3.00 log copies/ml. The NucliSens v2.0 assay underestimated A1 samples and those with viral loads of >3.00 log copies/ml. The RealTime assay tended to underquantify subtype C (compared to the Xpert and Aptima assays) and subtype A1 samples. The Xpert and Aptima assays were equally efficient for detection of all subtypes and viral loads, which renders these new assays most suitable for clinical HIV laboratories.
引用
收藏
页码:3458 / 3465
页数:8
相关论文
共 50 条
  • [31] Multicenter evaluation of Xpert HIV-1 viral load assay for HIV quantification in China
    Liu, Lifeng
    Deng, Renni
    Lan, Yun
    Li, Li
    Li, Mei
    Su, Bin
    Gnanashanmugam, Devasena
    Tang, Yi-Wei
    Wu, Hao
    Wang, Jing
    Cai, Xiaoli
    Zhang, Tong
    JOURNAL OF MEDICAL VIROLOGY, 2020, 92 (12) : 3295 - 3300
  • [32] PERFORMANCE EVALUATION OF THE GENEXPERT HIV-1 QUANT ASSAY FOR DETECTION OF HIV-1 IN PLASMA
    McNally, L.
    Carrera, A.
    Sherring, J.
    Cunningham, P. H.
    SEXUALLY TRANSMITTED INFECTIONS, 2015, 91 : A223 - A223
  • [33] Comparative evaluation of the Artus HIV-1 QS-RGQ assay and the Abbott RealTime HIV-1 assay for the quantification of HIV-1 RNA in plasma
    Garcia-Diaz, Ana
    Labbett, Wendy
    Clewley, Gillian S.
    Guerrero-Ramos, Alvaro
    Geretti, Anna Maria
    JOURNAL OF CLINICAL VIROLOGY, 2013, 57 (01) : 66 - 69
  • [34] Evaluation of the Aptima HIV-1 Quant Dx assay for HIV diagnosis at birth in South Africa
    Mukendi, Aurelie
    Kufa, Tendesayi
    Sherman, Gayle G.
    Technau, Karl-Gunter
    Tiemessen, Caroline T.
    Mazanderani, Ahmad Haeri
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2021, 101 (03)
  • [35] Evaluation of Hologic Aptima HIV-1 Quant Dx Assay on the Panther System on HIV Subtypes
    Manak, Mark M.
    Hack, Holly R.
    Nair, Sangeetha V.
    Worlock, Andrew
    Malia, Jennifer A.
    Peel, Sheila A.
    Jagodzinski, Linda L.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2016, 54 (10) : 2575 - 2581
  • [36] Performance evaluation of the Aptima HIV-1 Quant Dx assay for detection of HIV in infants in Kenya
    Mwau, Matilu
    Mbugua, Joseph
    Danda, Jeff
    Handa, Allan
    Worlock, Andrew
    Kim, Hee Cheol
    Kang, Youna
    Nair, Sangeetha
    JOURNAL OF CLINICAL VIROLOGY, 2020, 125
  • [37] Evaluation of the NucliSens EasyQ v2.0 Assay in Comparison with the Roche Amplicor v1.5 and the Roche CAP/CTM HIV-1 Test v2.0 in Quantification of C-Clade HIV-1 in Plasma
    Muenchhoff, Maximilian
    Madurai, Savathee
    Hempenstall, Allison Jo
    Adland, Emily
    Carlqvist, Anna
    Moonsamy, Angeline
    Jaggernath, Manjeetha
    Mlotshwa, Busisiwe
    Siboto, Emma
    Ndung'u, Thumbi
    Goulder, Philip Jeremy Renshaw
    PLOS ONE, 2014, 9 (08):
  • [38] Performance of the Abbott RealTime™ HIV-1 assay for quantification of HIV-1 clades prevalent in China
    Xu, Sihong
    Song, Aijing
    Li, Xiuhua
    Li, Jingyun
    Bao, Zuoyi
    Mao, Panyong
    Zhao, Qing
    Wang, Youchun
    JOURNAL OF CLINICAL VIROLOGY, 2008, 41 (04) : 305 - 309
  • [39] Evaluation of the Cepheid Xpert® HIV-1 Viral Load assay
    McHugh, M.
    Renwick, L.
    Templeton, K.
    HIV MEDICINE, 2015, 16 : 50 - 50
  • [40] Quantification of HIV-1 viral load
    Maria Gonzalez-Alba, Jose
    Rodriguez-Dominguez, Mario
    Mateos Lindemann, Maria Luisa
    ENFERMEDADES INFECCIOSAS Y MICROBIOLOGIA CLINICA, 2011, 29 : 47 - 50