A Self-Powered UHF Passive Tag for Biomedical Temperature Monitoring

被引:2
作者
Zamora-Mejia, Gregorio [1 ,2 ]
Martinez-Castillo, Jaime [3 ]
Diaz-Sanchez, Alejandro [2 ]
Rocha-Perez, Jose M. [2 ]
Herrera-May, Agustin L. [3 ,4 ]
Zapata-Rodriguez, Uriel G. [5 ]
Carbajal-Gomez, Victor H. [1 ,2 ]
机构
[1] CONACyT, Consejo Nacl Ciencia & Tecnol, Ciudad De Mexico 03940, Mexico
[2] INAOE, Inst Nacl Astrofis Opt & Elect, Puebla 72840, Mexico
[3] UV, Ctr Invest Micro & Nanotecnol, Veracruz 94294, Mexico
[4] Univ Veracruzana, Fac Ingn Construcc & Habitat, Ingn Aplicada, Boca Del Rio 94294, Mexico
[5] Univ Veracruzana, Fac Ingn, Veracruz 94294, Mexico
关键词
temperature sensor; self-powered; biomedical; power harvester; dipole antenna; voltage regulator; temperature compensated current source; ring oscillator; CMOS; FLEXIBLE SENSORS; REFERENCE CIRCUIT; IMPLEMENTATION; RECTIFIER; DESIGN;
D O I
10.3390/electronics11071108
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Self-powered RF passive sensors have potential application in temperature measurements of patients with health problems. Herein, this work presents the design and implementation of a self-powered UHF passive tag prototype for biomedical temperature monitoring. The proposed battery-free sensor is composed of three basic building blocks: a high-frequency section, a micro-power management stage, and a temperature sensor. This passive temperature sensor uses an 860 MHz to 960 MHz RF carrier and a 1 W Effective Isotropic Radiated Power (EIRP) to harvest energy for its operation, showing a read range of 9.5 m with a 13.75 mu W power consumption, and an overall power consumption efficiency of 10.92% was achieved. The proposed device can measure temperature variations between 0 degrees C and 60 degrees C with a sensitivity of 823.29 Hz/degrees C and a standard error of 13.67 Hz/degrees C over linear regression. Circuit functionality was validated by means of post-layout simulations, characterization, and measurements of the manufactured prototype. The chip prototype was fabricated using a 0.18 mu m CMOS standard technology with a silicon area consumption of 1065 mu m x 560 mu m. The overall size of the self-powered passive tag is 8 cm x 2 cm, including both chip and antenna. The self-powered tag prototype could be employed for human body temperature monitoring.
引用
收藏
页数:33
相关论文
共 50 条
  • [31] Passive UHF RFID Tag for Multispectral Assessment
    Escobedo, Pablo
    Carvajal, Miguel A.
    Capitan-Vallvey, Luis F.
    Fernandez-Salmeron, Jose
    Martinez-Olmos, Antonio
    Palma, Alberto J.
    SENSORS, 2016, 16 (07)
  • [32] Self-Powered, Non-Toxic, Recyclable Thermogalvanic Hydrogel Sensor for Temperature Monitoring of Edibles
    Yang, Kun
    Bai, Chenhui
    Liu, Boyuan
    Liu, Zhoutong
    Cui, Xiaojing
    MICROMACHINES, 2023, 14 (07)
  • [33] A Self-Powered 3.26-μW 70-m Wireless Temperature Sensor Node for Power Grid Monitoring
    Chen, Mingyi
    Wang, Min
    Yu, Hengwei
    He, Guanghui
    Zhu, Yongxin
    Liu, Yadong
    Wang, Guoxing
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2018, 65 (11) : 8956 - 8965
  • [34] Enhanced variable reluctance energy harvesting for self-powered monitoring
    Zhang, Ying
    Wang, Wei
    Xie, Junxiao
    Lei, Yaguo
    Cao, Junyi
    Xu, Ye
    Bader, Sebastian
    Bowen, Chris
    Oelmann, Bengt
    APPLIED ENERGY, 2022, 321
  • [35] Self-Powered Smart Insole for Monitoring Human Gait Signals
    Wang, Wei
    Cao, Junyi
    Yu, Jian
    Liu, Rong
    Bowen, Chris R.
    Liao, Wei-Hsin
    SENSORS, 2019, 19 (24)
  • [36] SCAVM: A Self-powered Cardiac and Activity Vigilant Monitoring System
    Ruiz, Luis Lopez
    Ridder, Matthew
    Fan, Dawei
    Gong, Jiaqi
    Lach, John
    Strohmaier, Jason
    2017 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS), 2017,
  • [37] Self-Powered IoT-Enabled Water Monitoring System
    Mhaisen, Naram
    Abazeed, Omran
    Al Hariri, Youssef
    Alsalemi, Abdullah
    Halabi, Osama
    2018 INTERNATIONAL CONFERENCE ON COMPUTER AND APPLICATIONS (ICCA), 2018, : 41 - 45
  • [38] A Self-Powered Flexible Biosensor for Human Exercise Intensity Monitoring
    Mao, Yupeng
    Zhu, Yongsheng
    Jia, Changjun
    Zhao, Tianming
    Zhu, Jiabin
    JOURNAL OF NANOELECTRONICS AND OPTOELECTRONICS, 2021, 16 (05) : 699 - 706
  • [39] Development of self-powered smart bearing for health condition monitoring
    Zhang, Ying
    Cao, Junyi
    2018 IEEE/ASME INTERNATIONAL CONFERENCE ON ADVANCED INTELLIGENT MECHATRONICS (AIM), 2018, : 786 - 791
  • [40] Self-powered triboelectric MEMS accelerometer
    Alzgool, Mohammad
    Tian, Yu
    Davaji, Benyamin
    Towfighian, Shahrzad
    NANO ENERGY, 2023, 109