Bypass line assisted start-up of a loop heat pipe with a flat evaporator

被引:19
作者
Boo, Joon Hong [1 ]
Jung, Eui Guk [2 ]
机构
[1] Korea Aerosp Univ, Sch Aerosp & Mech Engn, Goyang 412791, Gyeonggi Do, South Korea
[2] Korea Aerosp Univ, Grad Sch, Dept Aerosp & Mech Engn, Goyang 412791, Gyeonggi Do, South Korea
关键词
Loop heat pipe; Flat evaporator; Start-up; Bypass line; MENISCUS TYPE EVAPORATOR; THERMAL PERFORMANCE;
D O I
10.1007/s12206-009-0405-5
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Loop heat pipes often experience start-up problems especially under low thermal loads. A bypass line was installed between the evaporator and the liquid reservoir to alleviate the difficulties associated with start-up of a loop heat pipe with flat evaporator. The evaporator and condenser had dimensions of 40 mm (W) by 50 mm (L). The wall and tube materials were stainless steel and the working fluid was methanol. Axial grooves were provided in the flat evaporator to serve as vapor passages. The inner diameters of liquid and vapor transport lines were 2 mm and 4 mm, respectively, and the length of the two lines was 0.5 m each. The thermal load range was up to 130 W for horizontal alignment with the condenser temperature of 10A degrees C. The experimental results showed that the minimum thermal load for start-up was lowered by 37% when the bypass line was employed.
引用
收藏
页码:1613 / 1619
页数:7
相关论文
共 50 条
  • [31] Overshoot temperature control on evaporator wall of loop heat pipe for space vehicle thermal control through bypass line under high thermal load
    Kwon, Cheong Hoon
    Jung, Eui Guk
    APPLIED THERMAL ENGINEERING, 2023, 219
  • [32] Experimental studies on the transient characteristics and start-up behaviour of a miniature loop heat pipe
    Nashine, Chandan
    Pandey, Manmohan
    Baraya, Kamlesh K.
    APPLIED THERMAL ENGINEERING, 2025, 259
  • [33] Study on start-up characteristics of loop heat pipe under low-power
    Wang, Shuangfeng
    Zhang, Weibao
    Zhang, Xianfeng
    Chen, Jinjian
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2011, 54 (04) : 1002 - 1007
  • [34] Experimental study on start-up characteristics of loop heat pipes
    Hongxing Zhang
    Guiping Lin
    Ting Ding
    Xingguo Shao
    R. G. Sudakov
    Yu. F. Maidanik
    Science in China Series E: Technological Sciences, 2005, 48 : 131 - 144
  • [35] Experimental study on start-up characteristics of loop heat pipes
    R.G. Sudakov
    Yu. F. Maidanik
    Science in China(Series E:Technological Sciences), 2005, (02) : 131 - 144
  • [36] Study on heat transfer performance for loop heat pipe with circular flat evaporator
    Nguyen, Xuan Hung
    Sung, Byung Ho
    Choi, Jeehoon
    Ryoo, Seong Ryoul
    Ko, Han Seo
    Kim, Chulju
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2012, 55 (04) : 1304 - 1315
  • [37] Experimental study on start-up characteristics of loop heat pipes
    Zhang, HX
    Lin, GP
    Ding, T
    Shao, XG
    Sudakov, RG
    Maidanik, YF
    SCIENCE IN CHINA SERIES E-TECHNOLOGICAL SCIENCES, 2005, 48 (02): : 131 - 144
  • [38] A review on start-up characteristics of the pulsating heat pipe
    Zhang, Dongwei
    He, Zhuantao
    Jiang, Erhui
    Shen, Chao
    Zhou, Junjie
    HEAT AND MASS TRANSFER, 2021, 57 (05) : 723 - 735
  • [39] Ceramic flat plate evaporator for loop heat pipe cooling of electronics
    Zimbeck, Walter
    Chaney, Jared
    Espinoza, Patricio
    Kroliczek, Edward
    Bugby, David C.
    Yuri, James
    Advances in Electronic Packaging 2005, Pts A-C, 2005, : 177 - 182
  • [40] Miniature loop heat pipe with flat evaporator for cooling computer CPU
    Singh, Randeep
    Akbarzadeh, Aliakbar
    Dixon, Chris
    Mochizuki, Mastaka
    Riehl, Roger R.
    IEEE TRANSACTIONS ON COMPONENTS AND PACKAGING TECHNOLOGIES, 2007, 30 (01): : 42 - 49