Ultrasound Backscatter Tensor Imaging (BTI): Analysis of the Spatial Coherence of Ultrasonic Speckle in Anisotropic Soft Tissues

被引:30
|
作者
Papadacci, Clement [1 ,2 ]
Tanter, Mickael [1 ,2 ]
Pernot, Mathieu [1 ,2 ]
Fink, Mathias [1 ,2 ]
机构
[1] ESPCI, Inst Langevin, CNRS UMR 7587, INSERM,U979, F-75005 Paris, France
[2] Univ Paris 07, Paris, France
基金
欧洲研究理事会;
关键词
MYOCARDIAL FIBER-ORIENTATION; IN-VIVO; ARCHITECTURE; DIRECTION; ATTENUATION; STRAIN;
D O I
10.1109/TUFFC.2014.2994
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The assessment of fiber architecture is of major interest in the progression of myocardial disease. Recent techniques such as magnetic resonance diffusion tensor imaging (MR-DTI) or ultrasound elastic tensor imaging (ETI) can derive the fiber directions by measuring the anisotropy of water diffusion or tissue elasticity, but these techniques present severe limitations in a clinical setting. In this study, we propose a new technique, backscatter tensor imaging (BTI), which enables determination of the fiber directions in skeletal muscles and myocardial tissues, by measuring the spatial coherence of ultrasonic speckle. We compare the results to ultrasound ETI. Acquisitions were performed using a linear transducer array connected to an ultrasonic scanner mounted on a motorized rotation device with angles from 0 degrees to 355 degrees by 5 degrees increments to image ex vivo bovine skeletal muscle and porcine left ventricular myocardial samples. At each angle, multiple plane waves were transmitted and the backscattered echoes recorded. The coherence factor was measured as the ratio of coherent intensity over incoherent intensity of backscattered echoes. In skeletal muscle, maximal/minimal coherence factor was found for the probe parallel/perpendicular to the fibers. In myocardium, the coherence was assessed across the entire myocardial thickness, and the position of maxima and minima varied transmurally because of the complex fibers distribution. In ETI, the shear wave speed variation with the probe angle was found to follow the coherence variation. Spatial coherence can thus reveal the anisotropy of the ultrasonic speckle in skeletal muscle and myocardium. BTI could be used on any type of ultrasonic scanner with rotating phased-array probes or 2-D matrix probes for noninvasive evaluation of myocardial fibers.
引用
收藏
页码:986 / 996
页数:11
相关论文
共 5 条
  • [1] Towards Backscatter Tensor Imaging (BTI): Analysis of the spatial coherence of ultrasonic speckle in anisotropic soft tissues
    Papadacci, Clement
    Pernot, Mathieu
    Tanter, Mickael
    Fink, Mathias
    2013 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2013, : 1200 - 1203
  • [2] Harmonic Spatial Coherence Imaging: An Ultrasonic Imaging Method Based on Backscatter Coherence
    Dahl, Jeremy J.
    Jakovljevic, Marko
    Pinton, Gianmarco F.
    Trahey, Gregg E.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2012, 59 (04) : 648 - 659
  • [3] Real-time speckle reduction and coherence enhancement in ultrasound imaging via nonlinear anisotropic diffusion
    Abd-Elmoniem, KZ
    Youssef, ABM
    Kadah, YM
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2002, 49 (09) : 997 - 1014
  • [4] Spatial coherence determination from the Fourier analysis of a resonant soft X-ray magnetic speckle pattern
    Bagschik, Kai
    Froemter, Robert
    Mueller, Leonard
    Roseker, Wojciech
    Bach, Judith
    Staeck, Philipp
    Thoennissen, Carsten
    Schleitzer, Stefan
    Berntsen, Magnus Hardensson
    Weier, Christian
    Adam, Roman
    Viefhaus, Jens
    Schneider, Claus Michael
    Gruebel, Gerhard
    Oepen, Hans Peter
    OPTICS EXPRESS, 2016, 24 (20): : 23162 - 23176
  • [5] Noninvasive Imaging of Thermal Fields Induced in Soft Tissues In Vitro by Pulsed Focused Ultrasound Using Analysis of Echoes Displacement
    Karwat, Piotr
    Litniewski, Jerzy
    Kujawska, Tamara
    Secomski, Wojciech
    Krawczyk, Kazimierz
    ARCHIVES OF ACOUSTICS, 2014, 39 (01) : 139 - 144