A METHOD TO AUTOMATE THE SEGMENTATION OF THE GTV AND ITV FOR LUNG TUMORS

被引:11
作者
Ehler, Eric D.
Bzdusek, Karl
Tome, Wolfgang A. [1 ]
机构
[1] Univ Wisconsin, Dept Human Oncol, Sch Med & Publ Hlth, Madison, WI 53792 USA
关键词
Automated segmentation; 4D treatment planning; Phase binning error; Maximum intensity projection; 4-DIMENSIONAL COMPUTED-TOMOGRAPHY; STEREOTACTIC RADIOTHERAPY; RESPIRATORY MOTION; CT SCANS; DEFINITION; LOCATION;
D O I
10.1016/j.meddos.2008.08.007
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Four-dimensional computed tomography (4D-CT) is a useful tool in the treatment of tumors that undergo significant motion. To fully utilize 4D-CT notion information in the treatment of mobile tumors such as lung cancer, autosegmentation methods will need to be developed. Using autosegmentation tools in the Pinnacle(3) v8.1t treatment planning system, 6 anonymized 4D-CT data sets were contoured. Two test indices were developed that can be used to evaluate which autosegmentation tools to apply to a given gross tumor volume (GTV) region of interest (ROI). The 4D-CT data sets had various phase binning error levels ranging from 3% to 29%. The appropriate autosegmentation method (rigid translational image registration and deformable surface mesh) was determined to properly delineate the GTV in all of the 4D-CT phases for the 4D-CT data sets with binning errors of up to 15%. The ITV was defined by 2 methods: a mask of the GTV in all 4D-CT phases and the maximum intensity projection. The differences in centroid position and volume were compared with manual segmentation studies in literature. The indices developed in this study, along with the autosegmentation tools in the treatment planning system, were able to automatically segment the GTV in the four 4D-CTs with phase binning errors or up to 15%. (C) 2009 American Association of Medical Dosimetrists.
引用
收藏
页码:145 / 153
页数:9
相关论文
共 24 条
[1]   Tumor location cannot predict the mobility of lung tumors: A 3D analysis of data generated from multiple CT scans [J].
de Koste, JRV ;
Lagerwaard, FJ ;
Nijssen-Visser, MRJ ;
Graveland, WJ ;
Senan, S .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 56 (02) :348-354
[2]   Four-dimensional treatment planning for stereotactic body radiotherapy [J].
Guckenberger, Matthias ;
Wilbert, Juergen ;
Krieger, Thomas ;
Richter, Anne ;
Baier, Kurt ;
Meyer, Juergen ;
Flentje, Michael .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (01) :276-285
[3]  
Kaus MR, 2004, LECT NOTES COMPUT SC, V3217, P1017
[4]   4-dimensional computed tomography imaging and treatment planning [J].
Keall, P .
SEMINARS IN RADIATION ONCOLOGY, 2004, 14 (01) :81-90
[5]  
Keall P.J., 2003, INT J RAD ONCOL BIOL, V57, pS8
[6]   Four-dimensional radiotherapy planning for DMLC-based respiratory motion tracking [J].
Keall, PJ ;
Joshi, S ;
Vedam, SS ;
Siebers, JV ;
Kini, VR ;
Mohan, R .
MEDICAL PHYSICS, 2005, 32 (04) :942-951
[7]   Acquiring 4D thoracic CT scans using a multislice helical method [J].
Keall, PJ ;
Starkschall, G ;
Shukla, H ;
Forster, KM ;
Ortiz, V ;
Stevens, CW ;
Vedam, SS ;
George, R ;
Guerrero, T ;
Mohan, R .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (10) :2053-2067
[8]   A continuous 4D motion model from multiple respiratory cycles for use in lung radiotherapy [J].
McClelland, Jamie R. ;
Blackall, Jane M. ;
Tarte, Segolene ;
Chandler, Adam C. ;
Hughes, Simon ;
Ahmad, Shahreen ;
Landau, David B. ;
Hawkes, David J. .
MEDICAL PHYSICS, 2006, 33 (09) :3348-3358
[9]   The impact of temporal inaccuracies on 4DCT image quality [J].
Mutaf, Y. D. ;
Antolak, J. A. ;
Brinkmann, D. H. .
MEDICAL PHYSICS, 2007, 34 (05) :1615-1622
[10]   The effectiveness of an immobilization device in conformal radiotherapy for lung tumor: Reduction of respiratory tumor movement and evaluation of the daily setup accuracy [J].
Negoro, Y ;
Nagata, Y ;
Aoki, T ;
Mizowaki, T ;
Araki, N ;
Takayama, K ;
Kokubo, M ;
Yano, S ;
Koga, S ;
Sasai, K ;
Shibamoto, Y ;
Hiraoka, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 50 (04) :889-898