Correlation Between Interimplant Distance and Crestal Bone Loss in Internal Connection Implants with Platform Switching

被引:10
作者
Jo, Deuk-Won [1 ]
Yi, Yang-Jin [1 ,2 ]
Kwon, Min-Jung [1 ]
Kim, Young-Kyun [2 ,3 ]
机构
[1] Seoul Natl Univ, Bundang Hosp, Dept Prosthodont, Sect Dent, Seoul, South Korea
[2] Seoul Natl Univ, Sch Dent, Seoul, South Korea
[3] Seoul Natl Univ, Bundang Hosp, Dept Oral & Maxillofacial Surg, Sect Dent, Seoul, South Korea
关键词
crestal bone loss; digital subtraction; internal connection; interim plant distance; platform switching; tissue thickness; PHOTOELASTIC ANALYSIS; HEIGHT; RESORPTION; STABILITY; PAPILLA;
D O I
10.11607/jomi.3141
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The aim of this study was to investigate the influence of interim plant distance of internal connection implants with platform switching on crestal bone loss using radiographic evaluation. Materials and Methods: The present study included patients missing two consecutive teeth in the posterior quadrant and receiving internal connection implants. Digital periapical radiographs were taken at the time of superstructure connection and at the time of more than 1 year of loading. Bone level change was measured on the modified image using a digital subtraction program. The crestal bone loss between implants and the horizontal and vertical loss of peri-implant marginal bone were evaluated, and the influence of interim plant distance on crestal bone loss was analyzed at alpha = .05. Results: A total of 10 pairs of implants having <= 3 mm of interim plant distance was included in this study (group 1). The other 15 pairs of implants having > 3 mm of interim plant distance were selected as a control group (group 2). After the mean 19.3 months of observation, the mean crestal bone loss between implants was -0.26 +/- 0.14 mm in group 1 and -0.23 +/- 0.29 mm in group 2 (P > .05). There was no significant difference between the interimplant distance and the crestal bone loss according to the regression analysis (P = .765). The mean horizontal and vertical marginal bone loss was -0.18 +/- 0.25 mm and -0.15 +/- 0.18 mm, respectively, in group 1 and -0.17 +/- 0.31 mm and -0.11 +/- 0.33 mm, respectively, in group 2. There were no significant differences between outside and inside bone loss of implants in horizontal and vertical change (P > .05). Conclusions: Within the limitations of the short term study, the interim plant distance did not affect the crestal bone loss with internal connection implants with platform switching. The horizontal and vertical marginal bone loss was found to be too small to result in overlapping loss of the interim plant crestal bone.
引用
收藏
页码:296 / 302
页数:7
相关论文
共 28 条
[1]   PHOTOELASTIC STRESS ANALYSIS OF EXTERNAL VERSUS INTERNAL IMPLANT-ABUTMENT CONNECTIONS [J].
Asvanund, Pattapon ;
Morgano, Steven M. .
JOURNAL OF PROSTHETIC DENTISTRY, 2011, 106 (04) :266-271
[2]   Platform Switching for Marginal Bone Preservation Around Dental implants: A Systematic Review and Meta-Analysis [J].
Atieh, Momen A. ;
Ibrahim, Hadeel M. ;
Atieh, Ahmad H. .
JOURNAL OF PERIODONTOLOGY, 2010, 81 (10) :1350-1366
[3]  
Bernardes SR, 2009, INT J ORAL MAX IMPL, V24, P781
[4]   Comparison of peri-implant bone level assessment in digitized conventional radiographs and digital subtraction images [J].
Bittar-Cortez, J. A. ;
Passeri, L. A. ;
de Almeida, S. M. ;
Haiter-Neto, F. .
DENTOMAXILLOFACIAL RADIOLOGY, 2006, 35 (04) :258-262
[5]   Bone alterations at implant-supported FDPs in relation to inter-unit distances: a 5-year radiographic study [J].
Chang, Moontaek ;
Wennstrom, Jan L. .
CLINICAL ORAL IMPLANTS RESEARCH, 2010, 21 (07) :735-740
[6]  
Choi KS, 2010, INT J ORAL MAX IMPL, V25, P681
[7]   Effect of Interimplant Distance (2 and 3 mm) on the Height of Interimplant Bone Crest: A Histomorphometric Evaluation [J].
Elian, Nicolas ;
Bloom, Mitchell ;
Dard, Michel ;
Cho, Sang-Choon ;
Trushkowsky, Richard D. ;
Tarnow, Dennis .
JOURNAL OF PERIODONTOLOGY, 2011, 82 (12) :1749-1756
[8]  
ERICSSON I, 1995, J CLIN PERIODONTOL, V22, P255
[9]  
Grunder U, 2005, INT J PERIODONT REST, V25, P113
[10]   Prospective study of tapered resorbable blasting media surface implant stability in the maxillary posterior area [J].
Kim, Young-Kyun ;
Kim, Su-Gwan ;
Kim, Jong-Hwa ;
Yi, Yang-Jin ;
Yun, Pil-Young .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2012, 114 (01) :E19-E24