Can We Really Close the Loop and How Soon? Accelerating the Availability of an Artificial Pancreas: A Roadmap to Better Diabetes Outcomes

被引:99
作者
Kowalski, Aaron J. [1 ]
机构
[1] Juvenile Diabet Res Fdn Int, New York, NY 10005 USA
关键词
INSULIN DELIVERY; TYPE-1; HYPOGLYCEMIA;
D O I
10.1089/dia.2008.0031
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Development of a closed-loop artificial pancreas has been a long-time goal that could transform diabetes management. The primary limitation until recent years was the lack of a robust and portable continuous glucose sensor. There has been significant progress over the past 5 years in the development and commercialization of continuous glucose monitoring (CGM) devices. Used adjunctively, CGM has been demonstrated to add significant value in improving diabetes management by increasing time spent in glycemic targets and improving overall glycemic control. However, these benefits are limited by the human user's finite capacity to respond to the data provided by the device. By automating even a portion of the insulin delivery functionality of combined sensor/pump systems via computer algorithm, impending excursions could be handled more quickly and effectively. This review will describe very promising preliminary closed-loop studies, describe a potential roadmap to an artificial pancreas that will be safe and effective, and propose a solution-a hypo-and hyperglycemia minimizing control-to-range approach-that may allow for near-term delivery of a semiautomated system to people with diabetes.
引用
收藏
页码:S113 / S119
页数:7
相关论文
共 28 条
[11]   Pharmacodynamics and stability of subcutaneously infused glucagon in a type 1 diabetic swine model in vivo [J].
El-Khatib, Firas H. ;
Jiang, John ;
Gerrity, Ross G. ;
Damiano, Edward R. .
DIABETES TECHNOLOGY & THERAPEUTICS, 2007, 9 (02) :135-144
[12]  
ELKHATIB FH, 2009, J DIABETES SCI TECHN, V3, P384
[13]   Improvement in glycemic excursions with a transcutaneous, real-time continuous glucose sensor [J].
Garg, S ;
Zisser, H ;
Schwartz, S ;
Bailey, T ;
Kaplan, R ;
Ellis, S ;
Jovanovic, L .
DIABETES CARE, 2006, 29 (01) :44-50
[14]   Continuous glucose monitoring and closed-loop systems [J].
Hovorka, R .
DIABETIC MEDICINE, 2006, 23 (01) :1-12
[15]  
HOVORKA R, 2009, OVERNIGHT CLOSED LOO
[16]   The Future of Continuous Glucose Monitoring: Closed Loop [J].
Hovorka, Roman .
CURRENT DIABETES REVIEWS, 2008, 4 (03) :269-279
[17]   Evaluating the Accuracy, Reliability, and Clinical Applicability of Continuous Glucose Monitoring (CGM): Is CGM Ready for Real Time? [J].
Mazze, Roger S. ;
Strock, Ellie ;
Borgman, Sarah ;
Wesley, David ;
Stout, Philip ;
Racchini, Joel .
DIABETES TECHNOLOGY & THERAPEUTICS, 2009, 11 (01) :11-18
[18]  
Nathan DM, 2008, DIABETES CARE, V31, P173, DOI [10.2337/dc08-9016, 10.2337/dc08-0545]
[19]  
Perrow C., 1999, Normal accidents: Living with highrisk technologies, V2nd ed.
[20]  
Schatz H, 1976, MMW Munch Med Wochenschr, V118, P485