Short-term reproducibility of the 24-h ambulatory monitoring of brachial and central hemodynamics in untreated Chinese

被引:4
|
作者
Wang, Ying [1 ,2 ]
Zhang, Dong-Yan [1 ,2 ]
Guo, Qian-Hui [1 ,2 ]
Cheng, Yi-Bang [1 ,2 ]
Huang, Qi-Fang [1 ,2 ]
Sheng, Chang-Sheng [1 ,2 ]
Xu, Ting-Yan [1 ,2 ]
Wang, Ji-Guang [1 ,2 ]
Li, Yan [1 ,2 ]
机构
[1] Shanghai Jiao Tong Univ, Ruijin Hosp, Sch Med, Ctr Epidemiol Studies & Clin Trials, Ruijin 2nd Rd 197, Shanghai 200025, Peoples R China
[2] Shanghai Jiao Tong Univ, Ruijin Hosp, Shanghai Key Lab Hypertens, Ctr Vasc Evaluat,Shanghai Inst Hypertens,Sch Med, Ruijin 2nd Rd 197, Shanghai 200025, Peoples R China
基金
中国国家自然科学基金;
关键词
Ambulatory blood pressure monitoring; central blood pressure; pulse wave velocity; augmentation index; reproducibility; BLOOD-PRESSURE-MEASUREMENTS; ARTERIAL STIFFNESS INDEX; HEART-RATE-VARIABILITY; PULSE-WAVE VELOCITY; OSCILLOMETRIC ESTIMATION; PRACTICE GUIDELINES; EUROPEAN-SOCIETY; HYPERTENSION; VALIDATION; MANAGEMENT;
D O I
10.1080/08037051.2019.1612707
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Objective: Advanced technology allows non-invasive monitoring of the 24-h brachial and central hemodynamics simultaneously. However, related reproducibility data was limited in White patients. We therefore explored if the novel measurements would be reproducible in Chinese.Methods: From February 2017 to January 2018, 152 untreated patients who were suspected of hypertension and referred for ambulatory blood pressure (BP) monitoring were recruited. Ambulatory BP monitoring was repeated within one month (median, 12.5 days) using the Mobil-O-Graph monitors (IEM, Germany). Reproducibility was assessed as the intra-class correlation coefficient (ICC), coefficient of variation (CV), and repeatability coefficient (RC).Results: The 152 participants (average age, 58.6 years) included 54 men and 98 women. The first and second means of the ambulatory brachial and central BPs, pulse wave velocity (PWV), augmentation pressure, augmentation index (AIx) and AIx at a heart rate of 75 beats per minute (AIx@75) were all similar (p >= 0.065), except that the repeated daytime and 24-h brachial and central systolic BPs and pulse pressure slightly differed by approximately 1-2mmHg (p <= 0.011). ICC ranged from 0.70 to 0.94 for all ambulatory BPs and >= 0.91 for the arterial measurements. CV was in the range from 5.0% to 10.3% for all BPs and PWV measurements, and from 15.5% to 22.3% for AIx and AIx@75. RC expressed as percentages of maximal variation was <15% for the PWVs and ranged from 25.5% to 54.7% for BPs, AIx and AIx@75.Conclusions: The 24-h ambulatory brachial and central BPs and arterial measurements were reproducible within a short time period in Chinese, and could therefore be used in clinical practice and research settings.
引用
收藏
页码:250 / 257
页数:8
相关论文
共 50 条
  • [41] Short-term testing of heart rate variability in heart-transplanted children: equal to 24-h ECG recordings?
    Pozza, R. Dalla
    Fuchs, A.
    Bechtold, S.
    Netz, H.
    CLINICAL TRANSPLANTATION, 2006, 20 (04) : 438 - 442
  • [42] Parasympathetic dysfunction in hypertrophic cardiomyopathy assessed by heart rate variability:: comparison between short-term and 24-h measurements
    Mörner, S
    Wiklund, U
    Rask, P
    Olofsson, BO
    Kazzam, E
    Waldenström, A
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2005, 25 (02) : 90 - 99
  • [43] Association of blood manganese concentrations with 24-h based brachial and central blood pressure, and pulse-wave velocity.
    Carrasco-Rios, M.
    Ortola, R.
    Sotos-Prieto, M.
    Graciani, A.
    Rodriguez-Artalejo, F.
    Banegas, J. R.
    Garcia-Esquinas, E.
    ENVIRONMENTAL RESEARCH, 2023, 225
  • [44] Feasibility of 24-h central blood pressure monitoring: experience from multinational clinical trial assessing the efficacy of perindopril/indapamide/amlodipine
    Topouchian, Jirar
    Mourad, Jean-Jacques
    De Champvallins, Martine
    Feldmann, Luc
    Asmar, Roland
    JOURNAL OF HYPERTENSION, 2019, 37 (12) : 2442 - 2451
  • [45] Efficacy of Low-Dose Chlorthalidone and Hydrochlorothiazide as Assessed by 24-h Ambulatory Blood Pressure Monitoring
    Pareek, Anil K.
    Messerli, Franz H.
    Chandurkar, Nitin B.
    Dharmadhikari, Shruti K.
    Godbole, Anil V.
    Kshirsagar, Prasita P.
    Agarwal, Manish A.
    Sharma, Kamal H.
    Mathur, Shyam L.
    Kumbla, Mukund M.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 67 (04) : 379 - 389
  • [46] How reliable is isolated clinical hypertension defined by a single 24-h ambulatory blood pressure monitoring?
    Cuspidi, Cesare
    Meani, Stefano
    Sala, Carla
    Valerio, Cristiana
    Fusi, Veronica
    Zanchetti, Alberto
    Mancia, Giuseppe
    JOURNAL OF HYPERTENSION, 2007, 25 (02) : 315 - 320
  • [47] Acceptability and Adherence to Home, Kiosk, and Clinic Blood Pressure Measurement Compared to 24-H Ambulatory Monitoring
    Matthew J. Thompson
    Melissa L. Anderson
    Andrea J. Cook
    Kelly Ehrlich
    Yoshio N. Hall
    Clarissa Hsu
    Karen L. Margolis
    Jennifer B. McClure
    Sean A. Munson
    Beverly B. Green
    Journal of General Internal Medicine, 2023, 38 : 1854 - 1861
  • [48] ASSESSMENT OF SALT SENSITIVITY IN ESSENTIAL-HYPERTENSION BY 24-H AMBULATORY BLOOD-PRESSURE MONITORING
    DELASIERRA, A
    LLUCH, MD
    COCA, A
    AGUILERA, MT
    SANCHEZ, M
    SIERRA, C
    URBANOMARQUEZ, A
    AMERICAN JOURNAL OF HYPERTENSION, 1995, 8 (10) : 970 - 977
  • [49] Seven-day (24-h) ambulatory blood pressure monitoring, self-reported depression and quality of life scores
    Shinagawa, M
    Otsuka, K
    Murakami, S
    Kubo, Y
    Cornelissen, G
    Matsubayashi, K
    Yano, S
    Mitsutake, G
    Yasaka, K
    Halberg, F
    BLOOD PRESSURE MONITORING, 2002, 7 (01) : 69 - 76
  • [50] The correlation between isolated interventricular septal hypertrophy and 24-h ambulatory blood pressure monitoring in apparently healthy air crew
    Harpaz, D
    Rosenthal, T
    Peleg, E
    Shamiss, A