Short-term reproducibility of the 24-h ambulatory monitoring of brachial and central hemodynamics in untreated Chinese

被引:4
|
作者
Wang, Ying [1 ,2 ]
Zhang, Dong-Yan [1 ,2 ]
Guo, Qian-Hui [1 ,2 ]
Cheng, Yi-Bang [1 ,2 ]
Huang, Qi-Fang [1 ,2 ]
Sheng, Chang-Sheng [1 ,2 ]
Xu, Ting-Yan [1 ,2 ]
Wang, Ji-Guang [1 ,2 ]
Li, Yan [1 ,2 ]
机构
[1] Shanghai Jiao Tong Univ, Ruijin Hosp, Sch Med, Ctr Epidemiol Studies & Clin Trials, Ruijin 2nd Rd 197, Shanghai 200025, Peoples R China
[2] Shanghai Jiao Tong Univ, Ruijin Hosp, Shanghai Key Lab Hypertens, Ctr Vasc Evaluat,Shanghai Inst Hypertens,Sch Med, Ruijin 2nd Rd 197, Shanghai 200025, Peoples R China
基金
中国国家自然科学基金;
关键词
Ambulatory blood pressure monitoring; central blood pressure; pulse wave velocity; augmentation index; reproducibility; BLOOD-PRESSURE-MEASUREMENTS; ARTERIAL STIFFNESS INDEX; HEART-RATE-VARIABILITY; PULSE-WAVE VELOCITY; OSCILLOMETRIC ESTIMATION; PRACTICE GUIDELINES; EUROPEAN-SOCIETY; HYPERTENSION; VALIDATION; MANAGEMENT;
D O I
10.1080/08037051.2019.1612707
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Objective: Advanced technology allows non-invasive monitoring of the 24-h brachial and central hemodynamics simultaneously. However, related reproducibility data was limited in White patients. We therefore explored if the novel measurements would be reproducible in Chinese.Methods: From February 2017 to January 2018, 152 untreated patients who were suspected of hypertension and referred for ambulatory blood pressure (BP) monitoring were recruited. Ambulatory BP monitoring was repeated within one month (median, 12.5 days) using the Mobil-O-Graph monitors (IEM, Germany). Reproducibility was assessed as the intra-class correlation coefficient (ICC), coefficient of variation (CV), and repeatability coefficient (RC).Results: The 152 participants (average age, 58.6 years) included 54 men and 98 women. The first and second means of the ambulatory brachial and central BPs, pulse wave velocity (PWV), augmentation pressure, augmentation index (AIx) and AIx at a heart rate of 75 beats per minute (AIx@75) were all similar (p >= 0.065), except that the repeated daytime and 24-h brachial and central systolic BPs and pulse pressure slightly differed by approximately 1-2mmHg (p <= 0.011). ICC ranged from 0.70 to 0.94 for all ambulatory BPs and >= 0.91 for the arterial measurements. CV was in the range from 5.0% to 10.3% for all BPs and PWV measurements, and from 15.5% to 22.3% for AIx and AIx@75. RC expressed as percentages of maximal variation was <15% for the PWVs and ranged from 25.5% to 54.7% for BPs, AIx and AIx@75.Conclusions: The 24-h ambulatory brachial and central BPs and arterial measurements were reproducible within a short time period in Chinese, and could therefore be used in clinical practice and research settings.
引用
收藏
页码:250 / 257
页数:8
相关论文
共 50 条
  • [21] 24-h ambulatory blood pressure variability and hypertensive nephropathy in Han Chinese hypertensive patients
    Hung, Ming-Hui
    Huang, Chin-Chou
    Chung, Chia-Min
    Chen, Jaw-Wen
    JOURNAL OF CLINICAL HYPERTENSION, 2021, 23 (02) : 281 - 288
  • [22] A cyclic fluctuation model for 24-h ambulatory blood pressure monitoring in Chinese patients with mild to moderate hypertension
    Yu-cheng Sheng
    Kun Wang
    Ling Xu
    Juan Yang
    Ying-chun He
    Qing-shan Zheng
    Acta Pharmacologica Sinica, 2013, 34 : 1043 - 1051
  • [23] A cyclic fluctuation model for 24-h ambulatory blood pressure monitoring in Chinese patients with mild to moderate hypertension
    Sheng, Yu-cheng
    Wang, Kun
    Xu, Ling
    Yang, Juan
    He, Ying-chun
    Zheng, Qing-shan
    ACTA PHARMACOLOGICA SINICA, 2013, 34 (08) : 1043 - 1051
  • [24] Association of central hemodynamics with estimated 24-h urinary sodium in patients with hypertension
    Park, Sungha
    Park, Jeong B.
    Lakatta, Edward G.
    JOURNAL OF HYPERTENSION, 2011, 29 (08) : 1502 - 1507
  • [25] Defining the nocturnal period in 24-h ambulatory blood pressure monitoring: a comparison of three methods
    Slusniene, Anzela
    Navickas, Petras
    Stankus, Albinas
    Lauceviciene, Ieva
    Ryliskyte, Ligita
    Laucevicius, Aleksandras
    BLOOD PRESSURE MONITORING, 2021, 26 (03) : 207 - 214
  • [26] Sustained high blood pressure and 24-h ambulatory blood pressure monitoring in Tanzanian adolescents
    Nsanya, Mussa K.
    Ayieko, Philip
    Hashim, Ramadhan
    Mgema, Ezekiel
    Fitzgerald, Daniel
    Kapiga, Saidi
    Peck, Robert N.
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [27] Acceptability and Adherence to Home, Kiosk, and Clinic Blood Pressure Measurement Compared to 24-H Ambulatory Monitoring
    Thompson, Matthew J. J.
    Anderson, Melissa L. L.
    Cook, Andrea J. J.
    Ehrlich, Kelly
    Hall, Yoshio N. N.
    Hsu, Clarissa
    Margolis, Karen L. L.
    McClure, Jennifer B. B.
    Munson, Sean A. A.
    Green, Beverly B. B.
    JOURNAL OF GENERAL INTERNAL MEDICINE, 2023, 38 (08) : 1854 - 1861
  • [28] Short-term outcome after ischemic stroke and 24-h blood pressure variability: association and predictors
    Kamieniarz-Medrygal, Maria
    Lukomski, Tomasz
    Kazmierski, Radoslaw
    HYPERTENSION RESEARCH, 2021, 44 (02) : 188 - 196
  • [29] Clinical Utility of 24-h Ambulatory Blood Pressure Monitoring in Hospitalized Patients with Chronic Kidney Disease
    Salagre, Santosh B.
    Ansari, Nigarbi N. A.
    Mali, Vandana S.
    INDIAN JOURNAL OF NEPHROLOGY, 2021, 31 (04) : 365 - 369
  • [30] Disparate Associations of 24-h Central Aortic and Brachial Cuff Blood Pressure With Hypertension-Mediated Organ Damage and Cardiovascular Risk
    Hu, Yueliang
    Zhao, Jiehui
    Wang, Qian
    Chao, Huijuan
    Tang, Biwen
    Cheng, Di
    Tan, Isabella
    Butlin, Mark
    Avolio, Alberto
    Wang, Weiliang
    Zuo, Junli
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9