Dynamic Modulated Brachytherapy (DMBT) Balloon Applicator for Accelerated Partial Breast Irradiation

被引:2
作者
Guy, Christopher L. [1 ]
Oh, Seungjong [2 ]
Han, Dae Yup [3 ]
Kim, Siyong [1 ]
Arthur, Douglas [1 ]
Song, William Y. [1 ]
机构
[1] Virginia Commonwealth Univ, Dept Radiat Oncol, 401 Coll St,POB 980058, Richmond, VA 23298 USA
[2] Allegheny Gen Hosp, Dept Radiat Oncol, Pittsburgh, PA 15212 USA
[3] Yale Univ, Sch Med, Dept Therapeut Radiol, New Haven, CT 06510 USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2019年 / 104卷 / 04期
关键词
IN-VIVO DOSIMETRY; DOSE-RATE BRACHYTHERAPY; ELECTROMAGNETIC TRACKING; QUALITY-ASSURANCE; CERVICAL-CANCER; INTERSTITIAL BRACHYTHERAPY; CATHETER RECONSTRUCTION; PROSTATE BRACHYTHERAPY; RADIATION-THERAPY; MOSFET DETECTORS;
D O I
10.1016/j.ijrobp.2019.03.026
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To propose a novel high-dose-rate brachytherapy applicator for balloon-based dynamic modulated brachytherapy (DMBT) for accelerated partial breast irradiation (APBI) and to demonstrate its dosimetric advantage compared to the widely used Contura applicator. Methods and Materials: The DMBT balloon device consists of a fixed central channel enabling real-time, in vivo dosimetry and an outer motion-dynamic, adjustable-radius channel capable of moving to any angular position within the balloon. This design allows placement of dwell positions anywhere within the balloon volume, guaranteeing optimal placement and generation of the applicator and treatment plan, respectively. Thirteen clinical treatment plans for patients with early-stage breast cancer receiving APBI after lumpectomy using Contura were retrospectively obtained under institutional review board approval. New treatment plans were created by replacing the Contura with the DMBT device. DMBT plans were limited to 4 angular positions and an outer channel radius of 1.5 cm. The new plans were optimized to limit dose to ribs and skin while maintaining target coverage similar to that of the clinical plan. Results: Similar target coverage was obtained for the DMBT plans compared with clinical Contura plans. Across all patients the mean (standard deviation) reductions in D0.1 cc to the ribs and skin were 6.70% (6.28%) and 5.13% (6.54%), respectively. A threshold separation distance between the balloon surface and the organ at risk (OAR), below which dosimetric changes of greater than 5% were obtained, was observed to be 12 mm for ribs and skin. When both OARs were far from the balloon, DMBT plans were of similar quality to Contura plans, as expected. Conclusions: This study demonstrates the superior ability of the APBI DMBT applicator to spare OARs while achieving target coverage comparable to current treatment plans, especially when in close proximity. The DMBT balloon may enable new modes of dynamic high-dose-rate treatment delivery and allow for ultrahypofractionated dose regimens to be safely used. (C) 2019 Elsevier Inc. All rights reserved.
引用
收藏
页码:953 / 961
页数:9
相关论文
共 50 条
  • [41] Dosimetric characteristics of accelerated partial breast irradiation by interstitial multicatheter brachytherapy with intraoperative free-hand implantation in the treatment of early breast cancer
    Li, Chuan
    Lin, Jia-Fu
    Yeh, Hui Ling
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (03): : 27 - 34
  • [42] Current status of accelerated partial breast irradiation
    Michihide Mitsumori
    Masahiro Hiraoka
    Breast Cancer, 2008, 15 : 101 - 107
  • [43] Current modalities of accelerated partial breast irradiation
    Cox, John A.
    Swanson, Todd A.
    NATURE REVIEWS CLINICAL ONCOLOGY, 2013, 10 (06) : 344 - 356
  • [44] Accelerated partial breast irradiation: the new standard?
    Coles, C. E.
    Yarnold, J. R.
    LANCET, 2016, 387 (10015) : 201 - 202
  • [45] Phase 2 Trial of Accelerated Partial Breast Irradiation (APBI) Using Noninvasive Image Guided Breast Brachytherapy (NIBB)
    Hepel, Jaroslaw T.
    Leonard, Kara L.
    Sha, Sandra
    Graves, Theresa A.
    Wiggins, Doreen L.
    Mastras, Dean
    Pittier, Ann
    Wazer, David E.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (05): : 1143 - 1149
  • [46] Accelerated Partial Breast Irradiation: Efficacy and Outcomes
    Bauer, Elfrida
    Lester, Joanne L.
    CLINICAL JOURNAL OF ONCOLOGY NURSING, 2014, 18 (05) : 556 - 566
  • [47] Accelerated partial breast irradiation with multicatheters during breast conserving surgery for cancer
    Rodriguez-Spiteri Sagredo, Natalia
    Martinez Regueira, Fernando
    Olartecoechea Linaje, Begona
    Arredondo Chaves, Jorge
    Cambeiro Vazquez, Mauricio
    Pina Insausti, Luis Javier
    Elizalde Perez, Arlette
    Garcia-Lallana, Amaya
    Sola Gallego, Jose Javier
    CIRUGIA ESPANOLA, 2013, 91 (08): : 490 - 495
  • [48] Accelerated Partial Breast Irradiation in Clinical Practice
    Wenz, Frederik
    Sedlmayer, Felix
    Herskind, Carsten
    Welzel, Grit
    Sperk, Elena
    Neumaier, Christian
    Gauter-Fleckenstein, Benjamin
    Vaidya, Jayant S.
    Suetterlind, Marc
    BREAST CARE, 2015, 10 (04) : 247 - 252
  • [49] High-dose-rate interstitial brachytherapy for accelerated partial breast irradiation - trial results of Azerbaijan National Center of Oncology
    Aliyev, Jamil A.
    Isayev, Isa H.
    Akbarov, Kamal S.
    Qurbanov, Samir S.
    Huseynov, Ruston R.
    Aliyeva, Nigar S.
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2017, 9 (02) : 106 - 111
  • [50] Is stereotactic CyberKnife radiotherapy or multicatheter HDR brachytherapy the better option dosimetrically for accelerated partial breast irradiation?
    Frohlich, Georgina
    Meszaros, Norbert
    Smanyko, Viktor
    Stelczer, Gabor
    Herein, Andras
    Polgar, Csaba
    Major, Tibor
    BRACHYTHERAPY, 2021, 20 (02) : 326 - 331