Characterization of CdTe Detectors for Quantitative X-ray Spectroscopy

被引:86
作者
Redus, Robert H. [1 ]
Pantazis, John A. [1 ]
Pantazis, Thanos J. [1 ]
Huber, Alan C. [1 ]
Cross, Brian J. [2 ]
机构
[1] Amptek Inc, Bedford, MA 01730 USA
[2] CrossRd Sci, El Granada, CA 94018 USA
关键词
CdTe; CdTe detectors; charge collection; x-ray spectroscopy; HIGH-PERFORMANCE; LINESHAPES; SPECTRA;
D O I
10.1109/TNS.2009.2024149
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Silicon diodes have traditionally been the detectors of choice for quantitative X-ray spectroscopy. Their response has been very well characterized and existing software algorithms process the spectra for accurate, quantitative analysis. But Si diodes have limited sensitivity at energies above 30 keV, while recent regulations require measurement of heavy metals such as lead and mercury, with K X-ray emissions well above 30 keV. Measuring the K lines is advantageous to reduce the interference between the L lines of these elements with each other and with the K lines of light elements. CdTe has much higher stopping power than Si, making it attractive for measuring higher energies, but the quality and reproducibility of its spectra have limited its use in the energy range of characteristic X-rays, < 100 keV. CdTe detectors have now been optimized for energies < 100 keV, yielding electronic noise of 500 eV for a 5 mm x 5 mm x 0.75 mm device. This provides adequate energy resolution for distinguishing characteristic X-ray peaks < 30 keV. The response function of these CdTe detectors differs in important ways from that of Si detectors, requiring changes to the X-ray analytical software used to process the spectra. This paper will characterize the response of the latest generation of high resolution CdTe detectors at the energies of characteristic X-rays. It will present effects important for X-ray analysis, including the peak shape arising from hole tailing, escape peaks, spectral background, linearity, and stability. Finally, this paper will present spectral processing algorithms optimized for CdTe, including peak shape and escape peak algorithms.
引用
收藏
页码:2524 / 2532
页数:9
相关论文
共 31 条
[1]   ANALYTIC DESCRIPTION OF SI(LI) SPECTRAL LINESHAPES DUE TO MONOENERGETIC PHOTONS [J].
CAMPBELL, JL ;
PERUJO, A ;
MILLMAN, BM .
X-RAY SPECTROMETRY, 1987, 16 (05) :195-201
[2]  
Campbell JL, 1997, X-RAY SPECTROM, V26, P223, DOI 10.1002/(SICI)1097-4539(199707)26:4<223::AID-XRS224>3.3.CO
[3]  
2-#
[4]  
Chantler CT, 2009, NIST
[5]   Hand-Held Gamma-Ray Spectrometer Based on High-Efficiency Frisch-Ring CdZnTe Detectors [J].
Cui, Yonggang ;
Bolotnikov, Aleksey ;
Camarda, Giuseppe ;
Hossain, Anwar ;
James, Ralph B. ;
De Geronimo, Gianluigi ;
Fried, Jack ;
O'Connor, Paul ;
Kargar, Alireza ;
Harrison, Mark J. ;
McGregor, Douglas S. .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2008, 55 (05) :2765-2769
[6]   Characterization of charge collection in CdTe and CZT using the transient current technique [J].
Fink, J. ;
Krueger, H. ;
Lodomez, P. ;
Wermes, N. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 560 (02) :435-443
[7]   Methods for evaluating and analyzing CdTe and CdZnTe spectra [J].
Gunnink, R ;
Arlt, R .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 458 (1-2) :196-205
[8]  
GUNNINK R, 1972, UCRL51061 LAWR LIV N, V1
[9]   For the mechanism of the photoelectric primary current in insulating crystals. [J].
Hecht, Karl .
ZEITSCHRIFT FUR PHYSIK, 1932, 77 (3-4) :235-245
[10]   HIGH-PERFORMANCE, THERMOELECTRICALLY COOLED X-RAY AND GAMMA-RAY DETECTORS [J].
HUBER, AC ;
PANTAZIS, JA ;
JORDANOV, V .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1995, 99 (1-4) :665-668