CMR Reference Values for Left Ventricular Volumes, Mass, and Ejection Fraction Using Computer-Aided Analysis: The Framingham Heart Study

被引:46
作者
Chuang, Michael L. [1 ,2 ]
Gona, Philimon [1 ,3 ]
Hautvast, Gilion L. T. F. [4 ]
Salton, Carol J. [2 ]
Breeuwer, Marcel [4 ,5 ]
O'Donnell, Christopher J. [1 ,6 ,7 ]
Manning, Warren J. [2 ,7 ,8 ]
机构
[1] NHLBI, Framingham Heart Study, Framingham, MA 01702 USA
[2] Beth Israel Deaconess Med Ctr, Dept Med, Div Cardiovasc, Boston, MA 02215 USA
[3] Univ Massachusetts, Sch Med, Dept Quantitat Hlth Sci, Div Biostat & Hlth Serv Res, Worcester, MA USA
[4] Philips Heathcare, Imaging Syst, Best, Netherlands
[5] Eindhoven Univ Technol, NL-5600 MB Eindhoven, Netherlands
[6] Massachusetts Gen Hosp, Dept Med, Div Cardiol, Boston, MA 02114 USA
[7] Harvard Univ, Sch Med, Boston, MA USA
[8] Beth Israel Deaconess Med Ctr, Dept Radiol, Boston, MA 02215 USA
基金
美国国家卫生研究院;
关键词
left ventricle; reference values; automated border detection; magnetic resonance imaging; epidemiology; aging; CARDIOVASCULAR MAGNETIC-RESONANCE; CINE-MR-IMAGES; STUDY OFFSPRING COHORT; AUTOMATIC SEGMENTATION; VALIDATION; PARAMETERS; QUANTIFICATION; ATRIAL; AGE;
D O I
10.1002/jmri.24239
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo determine sex-specific reference values for left ventricular (LV) volumes, mass, and ejection fraction (EF) in healthy adults using computer-aided analysis and to examine the effect of age on LV parameters. Materials and MethodsWe examined data from 1494 members of the Framingham Heart Study Offspring cohort, obtained using short-axis stack cine SSFP CMR, identified a healthy reference group (without cardiovascular disease, hypertension, or LV wall motion abnormality) and determined sex-specific upper 95th percentile thresholds for LV volumes and mass, and lower 5th percentile thresholds for EF using computer-assisted border detection. In secondary analyses, we stratified participants by age-decade and tested for linear trend across age groups. ResultsThe reference group comprised 685 adults (423F; 61 9 years). Men had greater LV volumes and mass, before and after indexation to common measures of body size (all P = 0.001). Women had greater EF (73 +/- 6 versus 71 +/- 6%; P = 0.0002). LV volumes decreased with greater age in both sexes, even after indexation. Indexed LV mass did not vary with age. LV EF and concentricity increased with greater age in both sexes. ConclusionWe present CMR-derived LV reference values. There are significant age and sex differences in LV volumes, EF, and geometry, whereas mass differs between sexes but not age groups. J. Magn. Reson. Imaging 2014;39:895-900. (c) 2013 Wiley Periodicals, Inc.
引用
收藏
页码:895 / 900
页数:6
相关论文
共 24 条
[1]  
Abbott R.D., 1987, The Framingham Study: an epidemiological investigation of cardiovascular disease
[2]   Optimizing the automatic segmentation of the left ventricle in magnetic resonance images [J].
Angelié, E ;
de Koning, PJH ;
Danilouchkine, MG ;
van Assen, HC ;
Koning, G ;
van der Geest, RJ ;
Reiber, JHC .
MEDICAL PHYSICS, 2005, 32 (02) :369-375
[3]   Women have higher left ventricular ejection fractions than men independent of differences in left ventricular volume - The Dallas Heart Study [J].
Chung, AK ;
Das, SR ;
Leonard, D ;
Peshock, RM ;
Kazi, F ;
Abdullah, SM ;
Canham, RM ;
Levine, BD ;
Drazner, MH .
CIRCULATION, 2006, 113 (12) :1597-1604
[4]   Rapid and Accurate Left Ventricular Chamber Quantification Using a Novel CMR Segmentation Algorithm: A Clinical Validation Study [J].
Codella, Noel C. F. ;
Cham, Matthew D. ;
Wong, Richard ;
Chu, Christopher ;
Min, James K. ;
Prince, Martin R. ;
Wang, Yi ;
Weinsaft, Jonathan W. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 31 (04) :845-853
[5]   Automated Frame-by-Frame Endocardial Border Detection from Cardiac Magnetic Resonance Images for Quantitative Assessment of Left Ventricular Function: Validation and Clinical Feasibility [J].
Corsi, Cristiana ;
Veronesi, Federico ;
Lamberti, Claudio ;
Bardo, Dianna M. E. ;
Jamison, Ernest B. ;
Lang, Roberto M. ;
Mor-Avi, Victor .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 29 (03) :560-568
[6]   TrueFISP: Assessment of accuracy for measurement of left ventricular mass in an animal model [J].
Fieno, DS ;
Jaffe, WC ;
Simonetti, OP ;
Judd, RM ;
Finn, JP .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 15 (05) :526-531
[7]   Left ventricular mass:: Manual and automatic segmentation of true FISP and FLASH cine MR images in dogs and pigs [J].
François, CJ ;
Fieno, DS ;
Shors, SM ;
Finn, JP .
RADIOLOGY, 2004, 230 (02) :389-395
[8]   Experimental validation of an automated edge-detection method for a simultaneous determination of the endocardial and epicardial borders in short-axis cardiac MR images:: Application in normal volunteers [J].
Furber, A ;
Balzer, P ;
Cavaro-Ménard, C ;
Croué, A ;
Da Costa, E ;
Lethimonnier, F ;
Geslin, P ;
Tadéi, A ;
Jallet, P ;
Le Jeune, JJ .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (05) :1006-1014
[9]   Comparison of interstudy reproducibility of cardiovascular magnetic resonance with two-dimensional echocardiography in normal subjects and in patients with heart failure or left ventricular hypertrophy [J].
Grothues, F ;
Smith, GC ;
Moon, JCC ;
Bellenger, NG ;
Collins, P ;
Klein, HU ;
Pennell, DJ .
AMERICAN JOURNAL OF CARDIOLOGY, 2002, 90 (01) :29-34
[10]   Automatic contour propagation in cine cardiac magnetic resonance images [J].
Hautvast, Gilion ;
Lobregt, Steven ;
Breeuwer, Marcel ;
Gerritsen, Frans .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2006, 25 (11) :1472-1482