Development of the smartphone-based colorimetry for multi-analyte sensing arrays

被引:188
作者
Hong, Jong Il [1 ]
Chang, Byoung-Yong [1 ]
机构
[1] Pukyong Natl Univ, Dept Chem, Busan 608739, South Korea
基金
新加坡国家研究基金会;
关键词
MONITORING CHLORINE CONCENTRATION; POINT; PLATFORM;
D O I
10.1039/c3lc51451j
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Here we report development of a smartphone app (application) that digitizes the colours of a colorimetric sensor array. A conventional colorimetric sensor array consists of multiple paper-based sensors, and reports the detection results in terms of colour change. Evaluation of the colour changes is normally done by the naked eye, which may cause uncertainties due to personal subjectivity and the surrounding conditions. Solutions have been particularly sought in smartphones as they are capable of spectrometric functions. Our report specifically focuses on development of a practical app for immediate point-of-care (POC) multi-analyte sensing without additional devices. First, the individual positions of the sensors are automatically identified by the smartphone; second, the colours measured at each sensor are digitized based on a correction algorithm; and third, the corrected colours are converted to concentration values by pre-loaded calibration curves. All through these sequential processes, the sensor array taken in a smartphone snapshot undergoes laboratory-level spectrometry. The advantages of inexpensive and convenient paper-based colorimetry and the ubiquitous smartphone are tied to achieve a ready-to-go POC diagnosis.
引用
收藏
页码:1725 / 1732
页数:8
相关论文
共 29 条
[1]  
Bard A., 2002, ELECTROCHEMICAL METH, V2nd
[2]   Smartphone-based Chemistry Instrumentation: Digitization of Colorimetric Measurements [J].
Chang, Byoung-Yong .
BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2012, 33 (02) :549-552
[3]   A Large-Scale, Wireless Electrochemical Bipolar Electrode Microarray [J].
Chow, Kwok-Fan ;
Mavre, Francois ;
Crooks, John A. ;
Chang, Byoung-Yong ;
Crooks, Richard M. .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2009, 131 (24) :8364-+
[4]   Albumin testing in urine using a smart-phone [J].
Coskun, Ahmet F. ;
Nagi, Richie ;
Sadeghi, Kayvon ;
Phillips, Stephen ;
Ozcan, Aydogan .
LAB ON A CHIP, 2013, 13 (21) :4231-4238
[5]   Mobile phone platform as portable chemical analyzer [J].
Garcia, Antonio ;
Erenas, M. M. ;
Marinetto, Eugenio D. ;
Abad, Carlos A. ;
de Orbe-Paya, Ignacio ;
Palma, Alberto J. ;
Capitan-Vallvey, Luis F. .
SENSORS AND ACTUATORS B-CHEMICAL, 2011, 156 (01) :350-359
[6]   Point of Care Diagnostics: Status and Future [J].
Gubala, Vladimir ;
Harris, Leanne F. ;
Ricco, Antonio J. ;
Tan, Ming X. ;
Williams, David E. .
ANALYTICAL CHEMISTRY, 2012, 84 (02) :487-515
[7]   Disposable Amperometric Glycated Hemoglobin Sensor for the Finger Prick Blood Test [J].
Kim, Dong-Min ;
Shim, Yoon-Bo .
ANALYTICAL CHEMISTRY, 2013, 85 (13) :6536-6543
[8]  
Lee DS, 2011, LAB CHIP, V11, P120, DOI [10.1039/c0lc00209g, 10.1039/c01c00209g]
[9]   Membrane-Based, Sedimentation-Assisted Plasma Separator for Point-of-Care Applications [J].
Liu, Changchun ;
Mauk, Michael ;
Gross, Robert ;
Bushman, Frederic D. ;
Edelstein, Paul H. ;
Collman, Ronald G. ;
Bau, Haim H. .
ANALYTICAL CHEMISTRY, 2013, 85 (21) :10463-10470
[10]   Paper-Based Electrochemical Sensing Platform with Integral Battery and Electrochromic Read-Out [J].
Liu, Hong ;
Crooks, Richard M. .
ANALYTICAL CHEMISTRY, 2012, 84 (05) :2528-2532