Does off-pump total arterial grafting increase the incidence of intraoperative graft failure?

被引:30
作者
Balacumaraswami, L
Abu-Omar, Y
Anastasiadis, K
Choudhary, B
Pigott, D
Yeong, SK
Taggart, DP
机构
[1] John Radcliffe Hosp, Dept Cardiothorac Surg, Oxford OX3 9DU, England
[2] John Radcliffe Hosp, Dept Anesthesia, Oxford OX3 9DU, England
[3] Natl Res Council Canada, Ottawa, ON, Canada
关键词
D O I
10.1016/j.jtcvs.2003.11.072
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Early graft failure is a common cause of cardiac mortality and morbidity after coronary artery bypass grafting, but there is little information on its natural incidence. Furthermore, there is particular concern about graft patency in off-pump coronary artery bypass grafting and total arterial grafting. Methods: We performed a prospective observational study to assess intraoperative graft patency in patients undergoing off-pump and on-pump coronary artery bypass grafting, who also underwent total arterial grafting. We used an intraoperative imaging system, SPY (Novadaq Technologies Inc), based on the fluorescent properties of indocyanine green dye. Results: We assessed the intratoperative graft patency of 533 conduits in 200 patients. The mean number of grafts was 2.7 per patient. Of these patients, 155 (78%) had off-pump coronary artery bypass grafting, and 45 (22%) had on-pump coronary artery bypass grafting. Overall, 161 (80%) had total arterial grafting, with composite arterial grafting performed in 120 (60%) patients. Fluorescence, confirming graft patency, was observed in all but 8 (1.5%) conduits in 8 (4%) patients, necessitating graft revision. Six (3.9%) and 2 (4.4%) of these patients, respectively, had off-pump coronary artery bypass grafting and on-pump coronary artery bypass grafting. Conclusion: Intraoperative fluorescence imaging demonstrated a low (1.5%) but well-defined incidence of intraoperative graft failure, which affects around 4% of patients. This emphasizes the need for routine assessment of graft patency. Intraoperative fluorescence imaging permits detection and revision of failed grafts in the operating room. We found no difference in the incidence of failed grafts when comparing on-pump and off-pump total arterial grafting.
引用
收藏
页码:238 / 244
页数:7
相关论文
共 25 条
  • [1] Off-pump coronary artery bypass grafting
    Abu-Omar, Y
    Taggart, DP
    [J]. LANCET, 2002, 360 (9329) : 327 - 329
  • [2] Off-pump coronary surgery: Effect on early mortality and stroke
    Cheng, W
    Denton, TA
    Fontana, GP
    Raissi, S
    Blanche, C
    Kass, RM
    Magliato, KE
    Mirocha, J
    Trento, A
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2002, 124 (02) : 313 - 320
  • [3] Graft revision after transit time flow measurement in off-pump coronary artery bypass grafting
    D'Ancona, G
    Karamanoukian, HL
    Ricci, M
    Schmid, S
    Bergsland, J
    Salerno, TA
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2000, 17 (03) : 287 - 293
  • [4] Bilateral versus unilateral internal mammary revascularization in patients with diabetes
    Endo, M
    Tomizawa, Y
    Nishida, H
    [J]. CIRCULATION, 2003, 108 (11) : 1343 - 1349
  • [5] FALK V, 1995, J CARDIAC SURG, V10, P147
  • [6] An experimental approach to quantitative thermal coronary angiography
    Falk, V
    Walther, T
    Kitzinger, H
    Rauch, T
    Diegeler, A
    Autschbach, R
    Mohr, FW
    [J]. THORACIC AND CARDIOVASCULAR SURGEON, 1998, 46 (01) : 25 - 27
  • [7] Seven-year follow-up of coronary artery bypasses performed with and without cardiopulmonary bypass
    Gundry, SR
    Romano, MA
    Shattuck, OH
    Razzouk, AJ
    Bailey, LL
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1998, 115 (06) : 1273 - 1277
  • [8] Epicardial colour-Doppler scanning of coronary artery stenoses and graft anastomoses
    Haaverstad, R
    Vitale, N
    Williams, RI
    Fraser, AG
    [J]. SCANDINAVIAN CARDIOVASCULAR JOURNAL, 2002, 36 (02) : 95 - 99
  • [9] The importance of Intraoperative angiographic findings for predicting long-term patency in coronary artery bypass operations
    Hol, PK
    Fosse, E
    Lundblad, R
    Nitter-Hauge, S
    Due-Tonnessen, P
    Vatne, K
    Smith, HJ
    [J]. ANNALS OF THORACIC SURGERY, 2002, 73 (03) : 813 - 818
  • [10] A randomized comparison of off-pump and on-pump multivessel coronary-artery bypass surgery
    Khan, NE
    De Souza, A
    Mister, R
    Flather, M
    Clague, J
    Davies, S
    Collins, P
    Wang, DL
    Sigwart, U
    Pepper, J
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2004, 350 (01) : 21 - 28