High efficiency extreme ultraviolet overview spectrometer: Construction and laboratory testing

被引:16
作者
Biel, W.
Greiche, A.
Burhenn, R.
Jourdain, E.
Lepere, D.
机构
[1] Forschungszentrum Julich, Inst Plasmaphys, D-52425 Julich, Germany
[2] EURATOM, Trilateral Euregio Cluster, D-52425 Julich, Germany
[3] EURATOM, Max Planck Inst Plasmaphys, D-17491 Greifswald, Germany
[4] Jobin Yvon SAS, F-91165 Longjumeau, France
关键词
D O I
10.1063/1.2221659
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The new high efficiency extreme ultraviolet overview spectrometer system (HEXOS) has been developed to study impurity concentrations and impurity transport properties in the plasma of the stellarator W7-X. The HEXOS system consists of four different grating based spectrometers, which provide large etendue and good spectral resolution over a broad wavelength range (2.5-160 nm, divided into four subsections with some overlapping ). The mechanical arrangement as two double spectrometers allows for a compact installation geometry on W7-X. Laboratory testing and wavelength and intensity calibrations have been performed using a dc hollow cathode discharge (24-150 nm) and a pinch discharge (2.5-30 nm). (c) 2006 American Institute of Physics.
引用
收藏
页数:4
相关论文
共 12 条
[1]   IMPURITY AND RADIATION STUDIES DURING THE JET OHMIC HEATING PHASE [J].
BEHRINGER, KH ;
CAROLAN, PG ;
DENNE, B ;
DECKER, G ;
ENGELHARDT, W ;
FORREST, MJ ;
GILL, R ;
GOTTARDI, N ;
HAWKES, NC ;
KALLNE, E ;
KRAUSE, H ;
MAGYAR, G ;
MANSFIELD, M ;
MAST, F ;
MORGAN, P ;
PEACOCK, NJ ;
STAMP, MF ;
SUMMERS, HP .
NUCLEAR FUSION, 1986, 26 (06) :751-768
[2]   Highly repetitive, extreme-ultraviolet radiation source based on a gas-discharge plasma [J].
Bergmann, K ;
Schriever, G ;
Rosier, O ;
Muller, M ;
Neff, W ;
Lebert, R .
APPLIED OPTICS, 1999, 38 (25) :5413-5417
[3]   Design of a high-efficiency extreme ultraviolet overview spectrometer system for plasma impurity studies on the stellarator experiment Wendelstein 7-X [J].
Biel, W ;
Bertschinger, G ;
Burhenn, R ;
König, R ;
Jourdain, E .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2004, 75 (10) :3268-3275
[4]   Detector system with high time resolution for the continuous measurement of spectra in the vacuum ultraviolet wavelength range [J].
Biel, W ;
Bertschinger, G .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2004, 75 (07) :2471-2474
[5]   HIGH-CURRENT HOLLOW-CATHODE AS A RADIOMETRIC TRANSFER STANDARD SOURCE FOR THE EXTREME VACUUM ULTRAVIOLET [J].
DANZMANN, K ;
GUNTHER, M ;
FISCHER, J ;
KOCK, M ;
KUHNE, M .
APPLIED OPTICS, 1988, 27 (23) :4947-4951
[6]   MULTICHANNEL GRAZING-INCIDENCE SPECTROMETER FOR PLASMA IMPURITY DIAGNOSIS - SPRED [J].
FONCK, RJ ;
RAMSEY, AT ;
YELLE, RV .
APPLIED OPTICS, 1982, 21 (12) :2115-2123
[7]   GRAZING-INCIDENCE TIME-RESOLVING SPECTROGRAPH FOR MAGNETIC FUSION PLASMA DIAGNOSTICS [J].
HODGE, WL ;
STRATTON, BC ;
MOOS, HW .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1984, 55 (01) :16-24
[8]   HIGH-CURRENT HOLLOW-CATHODE SOURCE AS A RADIANT INTENSITY STANDARD IN THE 40-125-NM WAVELENGTH RANGE [J].
HOLLANDT, J ;
KUHNE, M ;
WENDE, B .
APPLIED OPTICS, 1994, 33 (01) :68-74
[9]   IMPURITIES IN TOKAMAKS [J].
ISLER, RC .
NUCLEAR FUSION, 1984, 24 (12) :1599-1678
[10]   MECHANICALLY RULED ABERRATION-CORRECTED CONCAVE GRATINGS FOR A FLAT-FIELD GRAZING-INCIDENCE SPECTROGRAPH [J].
KITA, T ;
HARADA, T ;
NAKANO, N ;
KURODA, H .
APPLIED OPTICS, 1983, 22 (04) :512-513