Closed-loop intracranial stimulation alters movement timing in humans

被引:5
作者
Moore, Bartlett D. [1 ]
Aron, Adam R. [2 ]
Tandon, Nitin [1 ,3 ]
机构
[1] McGovern Med Sch, Vivian L Smith Dept Neurosurg, Houston, TX USA
[2] Univ Calif San Diego, Dept Psychol, La Jolla, CA 92093 USA
[3] Mem Hermann Hosp, Texas Med Ctr, Mischer Neurosci Inst, Houston, TX USA
关键词
ECoG; Closed-loop; Supplementary motor area; SUPPLEMENTARY MOTOR AREA; TRANSCRANIAL MAGNETIC STIMULATION; DEEP BRAIN-STIMULATION; ELECTRICAL-STIMULATION; CORTEX; MONKEYS; PERFORMANCE; ACTIVATION; NEURONS; SYSTEM;
D O I
10.1016/j.brs.2018.03.003
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background: A prime objective driving the recent development of human neural prosthetics is to stimulate neural circuits in a manner time-locked to ongoing brain activity. The human supplementary motor area (SMA) is a particularly useful target for this objective because it displays characteristic neural activity just prior to voluntary movement. Objective: Here, we tested a method that detected activity in the human SMA related to impending movement and then delivered cortical stimulation with intracranial electrodes to influence the timing of movement. Methods: We conducted experiments in nine patients with electrodes implanted for epilepsy localization: five patients with SMA electrodes and four control patients with electrodes outside the SMA. In the first experiment, electrocorticographic (ECoG) recordings were used to localize the electrode of interest during a task involving bimanual finger movements. In the second experiment, a real-time sense-andstimulate (SAS) system was implemented that delivered an electrical stimulus when pre-movement gamma power exceeded a threshold. Results: Stimulation based on real-time detection of this supra-threshold activity resulted in significant slowing of motor behavior in all of the cases where stimulation was carried out in the SMA patients but in none of the patients where stimulation was performed at the control site. Conclusions: The neurophysiological correlates of impending movement can be used to trigger a closed loop stimulation device and influence ongoing motor behavior in a manner imperceptible to the subject. This is the first report of a human closed loop system designed to alter movement using direct cortical recordings and direct stimulation. Published by Elsevier Inc.
引用
收藏
页码:886 / 895
页数:10
相关论文
共 47 条
[41]   THE SUPPLEMENTARY MOTOR AREA IN THE CEREBRAL-CORTEX [J].
TANJI, J .
NEUROSCIENCE RESEARCH, 1994, 19 (03) :251-268
[42]   Critical review of the responsive neurostimulator system for epilepsy [J].
Thomas, George P. ;
Jobst, Barbara C. .
MEDICAL DEVICES-EVIDENCE AND RESEARCH, 2015, 8 :405-411
[43]   Chronometric Electrical Stimulation of Right Inferior Frontal Cortex Increases Motor Braking [J].
Wessel, Jan R. ;
Conner, Christopher R. ;
Aron, Adam R. ;
Tandon, Nitin .
JOURNAL OF NEUROSCIENCE, 2013, 33 (50) :19611-19619
[44]   Self-paced versus metronome-paced finger movements - A positron emission tomography study [J].
Wessel, K ;
Zeffiro, T ;
Toro, C ;
Hallett, M .
JOURNAL OF NEUROIMAGING, 1997, 7 (03) :145-151
[45]   Modulation of Orthographic Decoding by Frontal Cortex [J].
Whaley, Meagan Lee ;
Kadipasaoglu, Cihan Mehmet ;
Cox, Steven James ;
Tandon, Nitin .
JOURNAL OF NEUROSCIENCE, 2016, 36 (04) :1173-1184
[46]   Delay in simple reaction time after focal transcranial magnetic stimulation of the human brain occurs at the final motor output stage [J].
Ziemann, U ;
Tergau, F ;
Netz, J ;
Homberg, V .
BRAIN RESEARCH, 1997, 744 (01) :32-40
[47]   Closed-Loop Neuroscience and Non-Invasive Brain Stimulation: A Tale of Two Loops [J].
Zrenner, Christoph ;
Belardinelli, Paolo ;
Mueller-Dahlhaus, Florian ;
Ziemann, Ulf .
FRONTIERS IN CELLULAR NEUROSCIENCE, 2016, 10